Do you want to publish a course? Click here

A single-solenoid pulsed-magnet system for single-crystal scattering studies

190   0   0.0 ( 0 )
 Added by Zahirul Islam
 Publication date 2011
  fields Physics
and research's language is English




Ask ChatGPT about the research

We present a pulsed-magnet system that enables x-ray single-crystal diffraction in addition to powder and spectroscopic studies with the magnetic field applied on or close to the scattering plane. The apparatus consists of a single large-bore solenoid, cooled by liquid nitrogen. A second independent closed-cycle cryostat is used for cooling samples near liquid helium temperatures. Pulsed magnetic fields close to $sim 30$ T with a zero-to-peak-field rise time of $sim$2.9 ms are generated by discharging a 40 kJ capacitor bank into the magnet coil. The unique characteristic of this instrument is the preservation of maximum scattering angle ($sim 23.6^circ$) on the entrance and exit sides of the magnet bore by virtue of a novel double-funnel insert. This instrument will facilitate x-ray diffraction and spectroscopic studies that are impractical, if not impossible, to perform using split-pair and narrow-opening solenoid magnets, and offers a practical solution for preserving optical access in future higher-field pulsed magnets.



rate research

Read More

We present the first long-duration and high duty cycle 40-tesla pulsed-field cryomagnet addressed to single crystal neutron diffraction experiments at temperatures down to 2 K. The magnet produces a horizontal field in a bi-conical geometry, $pm$15 and $pm$30{deg} upstream and downstream of the sample, respectively. Using a 1.15MJ mobile generator, magnetic field pulses of 100 ms length are generated in the magnet, with a rise time of 23 ms and a repetition rate of 6-7 pulses per hour at 40 T. The setup was validated for neutron diffraction on the CEA-CRG three-axis spectrometer IN22 at the ILL.
469 - F. Duc , X. Fabr`eges , T. Roth 2014
We have developed a pulsed magnet system with panoramic access for synchrotron x-ray diffraction in magnetic fields up to 31T and at low temperature down to 1.5 K. The apparatus consists of a split-pair magnet, a liquid nitrogen bath to cool the pulsed coil, and a helium cryostat allowing sample temperatures from 1.5 up to 250 K. Using a 1.15MJ mobile generator, magnetic field pulses of 60 ms length were generated in the magnet, with a rise time of 16.5 ms and a repetition rate of 2 pulses/hour at 31 T. The setup was validated for single crystal diffraction on the ESRF beamline ID06.
72 - T. Yamazaki , T. Inada , T. Namba 2016
We have developed a repeating pulsed magnet system which generates magnetic fields of about 10 T in a direction transverse to an incident beam over a length of 0.8 m with a repetition rate of 0.2 Hz. Its repetition rate is by two orders of magnitude higher than usual pulsed magnets. It is composed of four low resistance racetrack coils and a 30 kJ transportable capacitor bank as a power supply. The system aims at axion-like particle searches with a pulsed light source and vacuum birefringence measurements. We report on the details of the system and its performances.
We have studied the frustrated system YBaCo4O7 generally described as an alternating stacking of Kagome and triangular layers of magnetic ions on a trigonal lattice, by single crystal neutron diffraction experiments above the Neel ordering transition. Experimental data reveals pronounced magnetic diffuse scattering, which is successfully modeled by direct Monte-Carlo simulations. Long-range magnetic correlations are found along the c-axis, due to the presence of corner-sharing bipyramids, creating quasi one-dimensional order at finite temperature. In contrast, in the Kagome layers ab-plane, the spin-spin correlation function -displaying a short-range 120 degrees configuration- decays rapidly as typically found in spin-liquids. YBaCo4O7 experimentally realizes a new class of two-dimensional frustrated systems where the strong out-of-plane coupling does not lift the in-plane degeneracy, but instead act as an external field.
We demonstrate niobium nitride based superconducting single-photon detectors sensitive in the spectral range 452 nm - 2300 nm. The system performance was tested in a real-life experiment with correlated photons generated by means of spontaneous parametric down conversion, where one of photon was in the visible range and the other was in the infrared range. We measured a signal to noise ratio as high as $4times 10^4$ in our detection setting. A photon detection efficiency as high as 64% at 1550 nm and 15% at 2300 nm was observed.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا