Do you want to publish a course? Click here

Strongly enhanced photon collection from diamond defect centres under micro-fabricated integrated solid immersion lenses

113   0   0.0 ( 0 )
 Added by Jp Hadden
 Publication date 2010
  fields Physics
and research's language is English




Ask ChatGPT about the research

The efficiency of collecting photons from optically active defect centres in bulk diamond is greatly reduced by refraction and reflection at the diamond-air interface. We report on the fabrication and measurement of a geometrical solution to the problem; integrated solid immersion lenses (SILs) etched directly into the surface of diamond. An increase of a factor of 10 was observed in the saturated count-rate from a single negatively charged nitrogen-vacancy (NV-) within a 5um diameter SIL compared with NV-s under a planar surface in the same crystal. A factor of 3 reduction in background emission was also observed due to the reduced excitation volume with a SIL present. Such a system is potentially scalable and easily adaptable to other defect centres in bulk diamond.

rate research

Read More

We describe a technique for fabricating micro- and nano-structures incorporating fluorescent defects in diamond with a positional accuracy in the hundreds of nanometers. Using confocal fluorescence microscopy and focused ion beam (FIB) etching we first locate a suitable defect with respect to registration marks on the diamond surface and then etch a structure using these coordinates. We demonstrate the technique here by etching an 8 micron diameter hemisphere positioned such that a single negatively charged nitrogen-vacancy defect lies at its origin. This type of structure increases the photon collection efficiency by removing refraction and aberration losses at the diamond-air interface. We make a direct comparison of the fluorescence photon count rate before and after fabrication and observe an 8-fold increase due to the presence of the hemisphere.
Recent efforts to define microscopic solid-immersion-lenses (SIL) by focused ion beam milling into diamond substrates that are registered to a preselected single photon emitter are summarized. We show how we determine the position of a single emitter with at least 100 nm lateral and 500 nm axial accuracy, and how the milling procedure is optimized. The characteristics of a single emitter, a Nitrogen Vacancy (NV) center in diamond, are measured before and after producing the SIL and compared with each other. A count rate of 1.0 million counts per second is achieved with a $[111]$ oriented NV center.
Single-photon sources represent a key enabling technology in quantum optics, and single colour centres in diamond are a promising platform to serve this purpose, due to their high quantum efficiency and photostability at room temperature. The widely studied nitrogen vacancy centres are characterized by several limitations, thus other defects have recently been considered, with a specific focus of centres emitting in the Near Infra-Red. In the present work, we report on the coupling of native near-infrared-emitting centres in high-quality single crystal diamond with Solid Immersion Lens structures fabricated by Focused Ion Beam lithography. The reported improvements in terms of light collection efficiency make the proposed system an ideal platform for the development of single-photon emitters with appealing photophysical and spectral properties.
One of the outstanding challenges for ion trap quantum information processing is to accurately detect the states of many ions in a scalable fashion. In the particular case of surface traps, geometric constraints make imaging perpendicular to the surface appealing for light collection at multiple locations with minimal cross-talk. In this report we describe an experiment integrating Diffractive Optic Elements (DOEs) with surface electrode traps, connected through in-vacuum multi-mode fibers. The square DOEs reported here were all designed with solid angle collection efficiencies of 3.58%; with all losses included a detection efficiency of 0.388% (1.02% excluding the PMT loss) was measured with a single Ca+ ion. The presence of the DOE had minimal effect on the stability of the ion, both in temporal variation of stray electric fields and in motional heating rates.
181 - J. Twamley , S. D. Barrett 2009
Circuit-QED has demonstrated very strong coupling between individual microwave photons trapped in a superconducting coplanar resonator and nearby superconducting qubits. In this work we show how, by designing a novel interconnect, one can strongly connect the superconducting resonator, via a magnetic interaction, to a small number (perhaps single), of electronic spins. By choosing the electronic spin to be within a Nitrogen Vacancy centre in diamond one can perform optical readout, polarization and control of this electron spin using microwave and radio frequency irradiation. More importantly, by utilising Nitrogen Vacancy centres with nearby 13C nuclei, using this interconnect, one has the potential build a quantum device where the nuclear spin qubits are connected over centimeter distances via the Nitrogen Vacancy electronic spins interacting through the superconducting bus.