Feasibility of 3D reconstructions from a single 2D diffraction measurement

128   0   0.0 ( 0 )
 Added by Pierre Thibault
 Publication date 2009
  fields Physics
and research's language is English




Ask ChatGPT about the research

We comment on the recent manuscript by Raines et al. [arXiv:0905.0269v2] (now published in Nature, vol. 463, p. 214-217, 2010), which suggests that in certain conditions a single diffraction measurement may be sufficient to reconstruct the full three-dimensional density of a scatterer. We show that past literature contains the tools to assess rigorously the feasibility of this approach. We question the formulation of the reconstruction algorithm used by the authors and we argue that the experimental data used as a demonstration is not suitable for this method, and thus that the reconstruction is not valid. This second version was produced for documentation purposes. In addition to the minimally modified original comment, it includes in appendix a subsequent reply to one of the authors (J. Miao).



rate research

Read More

In this paper, we propose the SPR (sparse phase retrieval) method, which is a new phase retrieval method for coherent x-ray diffraction imaging (CXDI). Conventional phase retrieval methods effectively solve the problem for high signal-to-noise ratio measurements, but would not be sufficient for single biomolecular imaging which is expected to be realized with femto-second x-ray free electron laser pulses. The SPR method is based on the Bayesian statistics. It does not need to set the object boundary constraint that is required by the commonly used hybrid input-output (HIO) method, instead a prior distribution is defined with an exponential distribution and used for the estimation. Simulation results demonstrate that the proposed method reconstructs the electron density under a noisy condition even some central pixels are masked.
114 - E. Vient , L. Manduci , E. Legouee 2017
In the domain of Fermi energy, it is extremely complex to isolate experimentally fragments and particles issued from the cooling of a hot nucleus produced during a heavy ion collision. This paper presents a new method to characterize more precisely hot Quasi-Projectiles. It tries to take into account as accurately as possible the distortions generated by all the other potential participants in the nuclear reaction. It is quantitatively shown that this method is a major improvement respect to classic calorimetries used with a 4$pi$ detector array. By detailing and deconvolving the different steps of the reconstitution of the hot nucleus, this study shows also the respective role played by the experimental device and the event selection criteria on the quality of the determination of QP characteristics.
Measurements are inseparable from inference, where the estimation of signals of interest from other observations is called an indirect measurement. While a variety of measurement limits have been defined by the physical constraint on each setup, the fundamental limit of an indirect measurement is essentially the limit of inference. Here, we propose the concept of statistical limits on indirect measurement: the bounds of distinction between signals and noise and between a signal and another signal. By developing the asymptotic theory of Bayesian regression, we investigate the phenomenology of a typical indirect measurement and demonstrate the existence of these limits. Based on the connection between inference and statistical physics, we also provide a unified interpretation in which these limits emerge from phase transitions of inference. Our results could pave the way for novel experimental design, enabling assess to the required quality of observations according to the assumed ground truth before the concerned indirect measurement is actually performed.
AMORPH utilizes a new Bayesian statistical approach to interpreting X-ray diffraction results of samples with both crystalline and amorphous components. AMORPH fits X-ray diffraction patterns with a mixture of narrow and wide components, simultaneously inferring all of the model parameters and quantifying their uncertainties. The program simulates background patterns previously applied manually, providing reproducible results, and significantly reducing inter- and intra-user biases. This approach allows for the quantification of amorphous and crystalline materials and for the characterization of the amorphous component, including properties such as the centre of mass, width, skewness, and nongaussianity of the amorphous component. Results demonstrate the applicability of this program for calculating amorphous contents of volcanic materials and independently modeling their properties in compositionally variable materials.
In 2011, a discrepancy between the values of the Planck constant measured by counting Si atoms and by comparing mechanical and electrical powers prompted a review, among others, of the measurement of the spacing of $^{28}$Si {220} lattice planes, either to confirm the measured value and its uncertainty or to identify errors. This exercise confirmed the result of the previous measurement and yields the additional value $d_{220}=192014711.98(34)$ am having a reduced uncertainty.