No Arabic abstract
Weakly Interacting Massive Particles (WIMPs) are candidates for non-baryonic Dark Matter. WIMPs are supposed to interact with baryonic matter via scattering off nuclei producing a nuclear recoil with energies up to a few 10 keV with a very low interaction rate of ~10^(-6) events per kg of target material and day in the energy region of interest. The Dark Matter experiment CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) and the EURECA project (European Underground Rare Event Calorimeter Array) are aimed at the direct detection of WIMPs with the help of very sensitive modularised cryogenic detectors that basically consist of a transition edge sensor (TES) in combination with a massive absorber crystal. In the CRESST experiment the search for coherent WIMP-nucleon scattering events is validated by the detection of two processes. In the scintillating absorber single crystal, CaWO_4, heat (phonons) and scintillation light are produced and detected with two independent cryogenic detectors: a phonon channel and a separate light channel. The development of such cryogenic detectors and the potential ton-scale production are investigated in this paper. To decouple the TES production from the choice of the target material in order to avoid heating cycles of the absorber crystal and to allow pretesting of the TESs, a composite detector design (CDD) for the detector production has been developed and studied. An existing thermal detector model has been extended to the CDD, in order to investigate, understand, and optimize the performance of composite detectors. This extended model, which has been worked out in detail, can be expected to provide a considerable help when tailoring composite detectors to the requirements of various experiments.
The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) and the EURECA (European Underground Rare Event Calorimeter Array) experiments are direct dark matter search experiments where cryogenic detectors are used to detect spin-independent, coherent WIMP (Weakly Interacting Massive Particle)-nucleon scattering events by means of the recoil energy. The cryogenic detectors use a massive single crystal as absorber which is equipped with a TES (transition edge sensor) for signal read-out. They are operated at mK-temperatures. In order to enable a mass production of these detectors, as needed for the EURECA experiment, a so-called composite detector design (CDD) that allows decoupling of the TES fabrication from the optimization procedure of the absorber single-crystal was developed and studied. To further investigate, understand and optimize the performance of composite detectors a detailed thermal detector model which takes into account the CDD has been developed.
The CRESST-III experiment which is dedicated to low-mass dark matter search uses scintillating CaWO$_4$ crystals operated as cryogenic particle detectors. Background discrimination is achieved by exploiting the scintillating light signal of CaWO$_4$ and by a novel active detector holder presented in this paper. In a test setup above ground, a nuclear-recoil energy threshold of $E_{th}=(190.6pm5.2)$eV is reached with a 24g prototype detector, which corresponds to an estimated threshold of $sim$50eV when being operated in the low-noise CRESST cryostat. This is the lowest threshold reported for direct dark matter searches. For CRESST-III phase 1, ten such detector modules were installed in the cryostat which have the potential to improve significantly the sensitivity to scatterings of dark matter particles with masses down to $sim$0.1GeV/c$^2$.
CRESST-II, standing for Cryogenic Rare Events Search with Superconducting Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order to detect WIMPs by elastic scattering off nuclei, generating phononic lattice excitations and scintillation light. The thermometers used in the experiment consist of a tungsten thin-film structure evaporated onto the CaWO4 absorber crystal. The process of evaporation causes a decrease in the scintillation light output. This, together with the need of a big-scale detector production for the upcoming EURECA experiment lead to investigations for producing thermometers on smaller crystals which are glued onto the absorber crystal. In our Run 31 we tested composite detectors for the first time in the Gran Sasso setup. They seem to produce higher light yields as hoped and could provide an additional time based discrimination mechanism for low light yield clamp events.
CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) is an experiment located at the Gran Sasso underground laboratory and aimed at the direct detection of dark matter in the form of WIMPs. The setup has just completed a one year commissioning run in 2007 and is presently starting a physics run with an increased target mass. Scintillating $mathrm{CaWO_4}$ single crystals, operated at temperatures of a few millikelvin, are used as target to detect the tiny nuclear recoil induced by a WIMP. The powerful background identification and rejection of $alpha$, e$^{-}$ and $gamma$ events is realized via the simultaneous measurement of a phonon and a scintillation signal generated in the $mathrm{CaWO_4}$ crystal. However, neutrons could still be misidentified as a WIMP signature. Therefore, a detailed understanding of the individual recoil behaviour in terms of phonon generation and scintillation light emission due to scattering on Ca, O or W nuclei, respectively, is mandatory. The only setup which allows to perform such measurements at the operating temperature of the CRESST detectors has been installed at the Maier-Leibnitz-Accelerator Laboratory in Garching and is presently being commissioned. The design of this neutron scattering facility is such that it can also be used for other target materials, e.g. $mathrm{ZnWO_4}$, $mathrm{PbWO_4}$ and others as foreseen in the framework of the future multitarget tonne-scale experiment EURECA (European Underground Rare Event Calorimeter Array).
At present the results in the field of direct dark matter search are in tension: the positive claim of DAMA/LIBRA versus null results from other experiments. However, the comparison of the results of different experiments involves model dependencies, in particular because of the different target materials in use. The COSINUS R&D project aims to operate NaI as a cryogenic calorimeter. Such a detector would not only allow for a direct comparison to DAMA/LIBRA, but would also provide a low(er) nuclear recoil threshold and particle discrimination.