In this research, a novel contact resistance model for the flat panel display (FPD) packaging based on the within layer parallel and between layers series resistance concepts was proposed. The FJ2530 anisotropic conductive films (ACF) by Sony Inc. containing the currently smallest 3micron conductive particles was used to conduct the experiments to verify the accuracy of the proposed model. Calculated resistance of the chip-on-glass (COG) packaging by the proposed model is 0.163Omega. It is found that the gold bump with 0.162Omega resistance play the major role of the overall resistance. Although the predicted resistance by the proposed model is only one third of the experimentally measured value, it has been three-fold improvement compared to the existing models.
A novel open waveguide cavity resonator is presented for the combined variable frequency microwave curing of bumps, underfills and encapsulants, as well as the alignment of devices for fast flip-chip assembly, direct chip attach (DCA) or wafer-scale level packaging (WSLP). This technology achieves radio frequency (RF) curing of adhesives used in microelectronics, optoelectronics and medical devices with potential simultaneous micron-scale alignment accuracy and bonding of devices. In principle, the open oven cavity can be fitted directly onto a flip-chip or wafer scale bonder and, as such, will allow for the bonding of devices through localised heating thus reducing the risk to thermally sensitive devices. Variable frequency microwave (VFM) heating and curing of an idealised polymer load is numerically simulated using a multi-physics approach. Electro-magnetic fields within a novel open ended microwave oven developed for use in micro-electronics manufacturing applications are solved using a de icated Yee scheme finite-difference time-domain (FDTD) solver. Temperature distribution, degree of cure and thermal stresses are analysed using an Unstructured Finite Volume method (UFVM) multi-physics package. The polymer load was meshed for thermophysical analysis, whilst the microwave cavity - encompassing the polymer load - was meshed for microwave irradiation. The two solution domains are linked using a cross-mapping routine. The principle of heating using the evanescent fringing fields within the open-end of the cavity is demonstrated. A closed loop feedback routine is established allowing the temperature within a lossy sample to be controlled. A distribution of the temperature within the lossy sample is obtained by using a thermal imaging camera.
A new Room Temperature (RT) 0-level vacuum package is demonstrated in this work, using amorphous silicon (aSi) as sacrificial layer and SiO2 as structural layer. The process is compatible with most of MEMS resonators and Resonant Suspended-Gate MOSFET [1] fabrication processes. This paper presents a study on the influence of releasing hole dimensions on the releasing time and hole clogging. It discusses mass production compatibility in terms of packaging stress during back-end plastic injection process. The packaging is done at room temperature making it fully compatible with IC-processed wafers and avoiding any subsequent degradation of the active devices.
This work relates to a novel piezoelectric transformer to be used in an autonomous sensor unit, possibly in conjunction with a RF-MEMS retro-modulator.
We performed resonant and nonresonant x-ray diffraction studies of a Nd0.5Sr0.5MnO3 thin film that exhibits a clear first-order transition. Lattice parameters vary drastically at the metal-insulator transition at 170K (=T_MI), and superlattice reflections appear below 140K (=T_CO). The electronic structure between T_MI and T_CO is identified as A-type antiferromagnetic with the d_{x2-y2} ferroorbital ordering. Below T_CO, a new type of antiferroorbital ordering emerges. The accommodation of the large lattice distortion at the first-order phase transition and the appearance of the novel orbital ordering are brought about by the anisotropy in the substrate, a new parameter for the phase control.
The present study presents a new micro electromagnetic actuator utilizing a PDMS membrane with a magnet. The actuator is integrated with micro coils to electromagnetically actuate the membrane and results in a large deflection. The micro electromagnetic actuator proposed in this study is easily fabricated and is readily integrated with existing bio-medical chips due to its planar structure.
Gou-Jen Wang
,Yi-Chin Lin
,Gwo-Sen Lin
.
(2007)
.
"A Novel Contact Resistance Model of Anisotropic Conductive Film for FPD Packaging"
.
EDA Publishing Association
هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا