For the development of charged particle detectors based on straw tubes operating in vacuum, a special measurement technique is required for the evaluation of their mechanical properties. A summary of the known equations that govern straw behavior under internal pressure is provided, and a new experimental method of a strained pressurized straw tube study is presented in this paper. The Poissons ratio of the straw wall, which defines the stability conditions of a built-in tube, is measured for the NA62 spectrometer straw, and its minimum pre-tension is estimated.