The behavior of the generation efficiency and radiation spectrum of a three-cavity axial vircator versus the radius of the injected electron beam, its impedance and energy homogeneity is studied. This paper establishes that for each geometry of a three-cavity resonator, there exist the optimal (maximizing the generation efficiency) values of these parameters and determines the range within which they may vary without losing the efficiency of generation.