ترغب بنشر مسار تعليمي؟ اضغط هنا

A Neutron Multiplicity Meter for Deep Underground Muon-Induced High Energy Neutron Measurements

41   0   0.0 ( 0 )
 نشر من قبل Raul Hennings-Yeomans
 تاريخ النشر 2006
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present the design of an instrument capable of measuring the high energy ($>$60 MeV) muon-induced neutron flux deep underground. The instrument is based on applying the Gd-loaded liquid-scintillator technique to measure the rate of high-energy neutrons underground based on the neutron multiplicity induced in a Pb target. We present design studies based on Monte Carlo simulations that show that an apparatus consisting of a Pb target of 200 cm by 200 cm area by 60 cm thickness covered by a 60 cm thick Gd-loaded liquid scintillator (0.5% Gd content) detector could measure, at a depth of 2000 meters of water equivalent, a rate of $70pm8$ (stat) events/year. Based on these studies, we also discuss the benefits of using a neutron multiplicity meter as a component of active shielding in such experiments.



قيم البحث

اقرأ أيضاً

175 - A.E. Lovell , I. Stetcu , P. Talou 2019
We propose a novel method to extract the prompt neutron multiplicity distribution, $P( u)$, in fission reactions based on correlations between prompt neutrons, $gamma$ rays, and fragment kinetic energy arising from energy conservation. In this approa ch, only event-by-event measurements of the total $gamma$-ray energy released as a function of the total kinetic energy (TKE) of the fission fragments are performed, and no neutron detection is required. Using the $texttt{CGMF}$ fission event generator, we illustrate the method and explore the accuracy of extracting the neutron multiplicity distribution when taking into account the energy resolution and calibration of the energy measurements. We find that a TKE resolution of under 2 MeV produces reasonably accurate results, independent of typical $gamma$-ray energy measurement resolution.
Solar-, geo-, and supernova neutrino experiments are subject to muon-induced radioactive background. China Jinping Underground Laboratory (CJPL), with its unique advantage of 2400 m rock coverage and distance from nuclear power plants, is ideal for M eV-scale neutrino experiments. Using a 1-ton prototype detector of the Jinping Neutrino Experiment (JNE), we detected 343 high-energy cosmic-ray muons and (6.24$ pm $3.66) muon-induced neutrons from an 820.28-day dataset at the first phase of CJPL (CJPL-I). Based on the muon induced neutrons, we measured the corresponding neutron yield in liquid scintillator to be $(3.13 pm 1.84_{rm stat.}pm 0.70_{rm syst.})times 10^{-4}mu ^{-1}rm g^{-1}cm^{2}$ at an average muon energy of 340 GeV. This study provides the first measurement for this kind of neutron background at CJPL. A global fit including this measurement shows a power-law coefficient of (0.75$ pm $0.02) for the dependence of the neutron yield at liquid scintillator on muon energy.
Absolute measurements of neutron fluence are an essential prerequisite of neutron-induced cross section measurements, neutron beam lines characterization and dosimetric investigations. The H(n,p) elastic scattering cross section is a very well known standard used to perform precise neutron flux measurements in high precision measurements. The use of this technique, with proton recoil detectors, is not straightforward below incident neutron energy of 1 MeV, due to a high background in the detected proton spectrum. Experiments have been carried out at the AIFIRA facility to investigate such background and to determine its origin and components. Based on these investigations, a gaseous proton-recoil detector has been designed with a reduced low energy background. A first test of this detector has been carried out at the AIFIRA facility, and first results will be presented.
64 - P. Marini , L. Mathieu , M. Aiche 2019
Absolute measurements of neutron flux are an essential prerequisite of neutron-induced cross section measurements, neutron beam lines characterization and dosimetric investigations. A new gaseous detector has been developed for measurements of 0.2 to 2 MeV neutron flux based on proton-recoil process. The detector, consisting of two segmented ionization chambers read by Micromegas technology, has beed conceived to provide quasi-absolute neutron flux measurements with an accuracy of simeq3%. The gas pressure flexibility makes the telescope non sensitive to {gamma} and electrons background, and therefore advantageous over semi-conductor materials as a neutron flux instrument. The adjustable gas pressure and H-sample thickness, the use of Micromegas technology and the tracking capabilities allows the detection of neutrons on a large dynamical range and down to 200 keV with a good rejection of scattered neutron events and random background
114 - Xi Yuan , Xing Zhang , Xufei Xie 2013
A neutron detector based on EJ301 liquid scintillator has been employed at EAST to measure the neutron energy spectrum for D-D fusion plasma. The detector was carefully characterized in different quasi-monoenergetic neutron fields generated by a 4.5 MV Van de Graaff accelerator. In recent experimental campaigns, due to the low neutron yield at EAST, a new shielding device was designed and located as close as possible to the tokamak to enhance the count rate of the spectrometer. The fluence of neutrons and gamma-rays was measured with the liquid neutron spectrometer and was consistent with 3He proportional counter and NaI (Tl) gamma-ray spectrometer measurements. Plasma ion temperature values were deduced from the neutron spectrum in discharges with lower hybrid wave injection and ion cyclotron resonance heating. Scattered neutron spectra were simulated by the Monte Carlo transport Code, and they were well verified by the pulse height measurements at low energies.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا