ترغب بنشر مسار تعليمي؟ اضغط هنا

Measurements of the Secondary Electron Emission from Rare Gases at 4.2K

124   0   0.0 ( 0 )
 نشر من قبل Frederic Le Pimpec
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Dependence of the secondary electron yield (SEY) from the primary beam incident energy and the coverage has been measured for neon, argon, krypton and xenon condensed on a target at 4.2K. The beam energy ranged between 100 eV and 3 keV, the maximal applied coverage have made up 12000, 4700, 2500 and 1400 monolayers correspondingly for neon, argon, krypton and xenon. The SEY results for these coverages can be considered as belonging only to investigated gases without influence of the target material. The SEY dependencies versus the primary beam energy for all gases comprise only an ascending part and therefore, the maximal measured SEY values have been obtained for the beam energy of 3keV and have made up 62, 73, 60.5 and 52 for neon, argon, krypton and xenon correspondingly. Values of the first cross-over have made up 21 eV for neon, 14 eV for argon, 12.5 eV for krypton and 10.5 eV for xenon. An internal field appearing across a film due to the beam impact can considerably affect the SEY measurements that demanded the beam current to be reduced till 9.0E-10A. Duration of the beam impact varied between 500 mu sec and 250 mu sec. It was found that reliable SEY measurements can also be taken on a charged surface if the charge was acquired due to beam impact with electrons of higher energy. All SEY measurements for once applied coverage have been carried out for whole range of incident energies from 3 keV down to 100 eV without renewing the film. Developing of pores inside of a deposited film can significantly increase the SEY as it was observed during warming up the target.



قيم البحث

اقرأ أيضاً

Charging up the surface of an insulator after beam impact can lead either to reverse sign of field between the surface and collector of electrons for case of thick sample or appearance of very high internal field for thin films. Both situations disca rd correct measurements of secondary electron emission (SEE) and can be avoided via reducing the beam dose. The single pulse method with pulse duration of order of tens microseconds has been used. The beam pulsing was carried out by means of an analog switch introduced in deflection plate circuit which toggles its output between beam on and beam off voltages depending on level of a digital pulse. The error in measuring the beam current for insulators with high value of SEE was significantly reduced due to the use for this purpose a titanium sample having low value of the SEE with DC method applied. Results obtained for some not coated insulators show considerable increase of the SEE after baking out at 3500C what could be explained by the change of work function. Titanium coatings on alumina exhibit results close to the ones for pure titanium and could be considered as an effective antimultipactor coating.
In the beam pipe of the positron damping ring of the Next Linear Collider, electrons will be created by beam interaction with the surrounding vacuum chamber wall and give rise to an electron cloud. Several solutions are possible for avoiding the elec tron cloud, without changing the bunch structure or the diameter of the vacuum chamber. Some of the currently available solutions for preventing this spurious electron load include reducing residual gas ionization by the beam, minimizing beam photon-induced electron production, and lowering the secondary electron yield (SEY) of the chamber wall. We will report on recent SEY measurements performed at SLAC on TiN coatings and TiZrV non-evaporable getter thin films.
Secondary electron emission (SEE) from solids plays an important role in many areas of science and technology.1 In recent years, there has been renewed interest in the experimental and theoretical studies of SEE. A recent study proposed that the refl ectivity of very low energy electrons from solid surface approaches unity in the limit of zero electron energy2,3,4, If this was indeed the case, this effect would have profound implications on the formation of electron clouds in particle accelerators,2-4 plasma measurements with electrostatic Langmuir probes, and operation of Hall plasma thrusters for spacecraft propulsion5,6. It appears that, the proposed high electron reflectivity at low electron energies contradicts to numerous previous experimental studies of the secondary electron emission7. The goal of this note is to discuss possible causes of these contradictions.
We discuss the progress made on a new installation in Fermilabs Main Injector that will help investigate the electron cloud phenomenon by making direct measurements of the secondary electron yield (SEY) of samples irradiated in the accelerator. In th e Project X upgrade the Main Injector will have its beam intensity increased by a factor of three compared to current operations. This may result in the beam being subject to instabilities from the electron cloud. Measured SEY values can be used to further constrain simulations and aid our extrapolation to Project X intensities. The SEY test-stand, developed in conjunction with Cornell and SLAC, is capable of measuring the SEY from samples using an incident electron beam when the samples are biased at different voltages. We present the design and manufacture of the test-stand and the results of initial laboratory tests on samples prior to installation.
In the beam pipe of the positron Main Damping Ring (MDR) of the Next Linear Collider (NLC), ionization of residual gases and secondary electron emission give rise to an electron cloud which can cause the loss of the circulating beam. One path to avoi d the electron cloud is to ensure that the vacuum wall has low secondary emission yield and, therefore, we need to know the secondary emission yield (SEY) for candidate wall coatings. We report on SEY measurements at SLAC on titanium nitride (TiN) and titanium-zirconium-vanadium (TiZrV) thin sputter-deposited films, as well as describe our experimental setup.