Digital control of optics experiments has many advantages over analog control systems, specifically in terms of scalability, cost, flexibility, and the integration of system information into one location. We present a digital control system, freely available for download online, specifically designed for quantum optics experiments that allows for automatic and sequential re-locking of optical components. We show how the inbuilt locking analysis tools, including a white-noise network analyzer, can be used to help optimize individual locks, and verify the long term stability of the digital system. Finally, we present an example of the benefits of digital locking for quantum optics by applying the code to a specific experiment used to characterize optical Schrodinger cat states.



قيم البحث

اقرأ أيضاً

By applying a high-reflectivity dielectric coating on both sides of a commercial plano-convex lens, we produce a stable monolithic Fabry-Perot cavity suitable for use as a narrow band filter in quantum optics experiments. The resonant frequency is se lected by means of thermal expansion. Owing to the long term mechanical stability, no optical locking techniques are required. We characterize the cavity performance as an optical filter, obtaining a 45 dB suppression of unwanted modes while maintaining a transmission of 60%.
High precision, high numerical aperture mirrors are desirable for mediating strong atom-light coupling in quantum optics applications and can also serve as important reference surfaces for optical metrology. In this work we demonstrate the fabricatio n of highly-precise hemispheric mirrors with numerical aperture NA = 0.996. The mirrors were fabricated from aluminum by single-point diamond turning using a stable ultra- precision lathe calibrated with an in-situ white-light interferometer. Our mirrors have a diameter of 25 mm and were characterized using a combination of wide-angle single- shot and small-angle stitched multi-shot interferometry. The measurements show root- mean-square (RMS) form errors consistently below 25 nm. The smoothest of our mirrors has a RMS error of 14 nm and a peak-to-valley (PV) error of 88 nm, which corresponds to a form accuracy of $lambda$=50 for visible optics.
We describe a general purpose digital servo optimized for feedback control of lasers in atomic, molecular, and optical (AMO) physics experiments. The servo is capable of feedback bandwidths up to roughly 1~MHz (limited by the 320~ns total latency); l oop filter shapes up to fifth order; multiple-input, multiple-output control; and automatic lock acquisition. The configuration of the servo is controlled via a graphical user interface, which also provides a rudimentary software oscilloscope and tools for measurement of system transfer functions. We illustrate the functionality of the digital servo by describing its use in two example scenarios: frequency control of the laser used to probe the narrow clock transition of $^{27}$Al$^+$ in an optical atomic clock, and length control of a cavity used for resonant frequency doubling of a laser.
A 33.6 ps LSB Time-to-Digital converter was designed in 130 nm BiCMOS technology. The core of the converter is a differential 9-stage ring oscillator, based on a multi-path architecture. A novel version of this design is proposed, along with an analy tical model of linearity. The model allowed us to understand the source of the performance superiority (in terms of linearity) of our design and to predict further improvements. The oscillator is integrated in a event-by-event self-calibration system that allows avoiding any PLL-based synchronization. For this reason and for the compactness and simplicity of the architecture, the proposed TDC is suitable for applications in which a large number of converters and a massive parallelization are required such as High-Energy Physics and medical imaging detector systems. A test chip for the TDC has been fabricated and tested. The TDC shows a DNL$leq$1.3 LSB, an INL$leq$2 LSB and a single-shot precision of 19.5 ps (0.58 LSB). The chip dissipates a power of 5.4 mW overall.
We present the first experimental confirmation of the so-called self-phaselocked delay interferometry. This laser frequency stabilization technique consists basically in comparing the prompt laser signal with a delayed version of itself that has been reflected in another LISA satellite 5 million km away. In our table-top experiment, the phase of a voltage-controlled oscillator is stabilized by means of a control loop based on this technique. In agreement with the theory, the measured unity gain frequency is not limited by the inverse of the used delay (1.6 microseconds). In the time domain, the system also behaves as predicted, including the appearance of a quasi-periodic ringing just after the lock acquisition, which decays exponentially. Its initial amplitude is smaller when the loop gain is slowly ramped up instead of suddenly switched on.