ترغب بنشر مسار تعليمي؟ اضغط هنا

Hysteretic ac loss of superconducting strips simultaneously exposed to ac transport current and phase-different ac magnetic field

229   0   0.0 ( 0 )
 نشر من قبل Yasunori Mawatari
 تاريخ النشر 2006
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A simple analytical expression is presented for hysteretic ac loss $Q$ of a superconducting strip simultaneously exposed to an ac transport current $I_0cosomega t$ and a phase-different ac magnetic field $H_0cos(omega t+theta_0)$. On the basis of Beans critical state model, we calculate $Q$ for small current amplitude $I_0ll I_c$, for small magnetic field amplitude $H_0ll I_c/2pi a$, and for arbitrary phase difference $theta_0$, where $I_c$ is the critical current and $2a$ is the width of the strip. The resulting expression for $Q=Q(I_0,H_0,theta_0)$ is a simple biquadratic function of both $I_0$ and $H_0$, and $Q$ becomes maximum (minimum) when $theta_0=0$ or $pi$ ($theta_0=pi/2$).



قيم البحث

اقرأ أيضاً

The hysteretic ac loss of a current-carrying conductor in which multiple superconducting strips are polygonally arranged around a cylindrical former is theoretically investigated as a model of superconducting cables. Using the critical state model, w e analytically derive the ac loss $Q_n$ of a total of $n$ strips. The normalized loss $Q_n/Q_1$ is determined by the number of strips $n$ and the ratio of the strip width $2w$ to the diameter $2R$ of the cylindrical former. When $n>> 1$ and $w/R<< 1$, the behavior of $Q_n$ is similar to that of an infinite array of coplanar strips.
99 - E. Pardo , F. Gomory , J. Souc 2005
The case of ac transport at in-phase alternating applied magnetic fields for a superconducting rectangular strip with finite thickness has been investigated. The applied magnetic field is considered perpendicular to the current flow. We present numer ical calculations assuming the critical state model of the current distribution and ac loss for various values of aspect ratio, transport current and applied field amplitude. A rich phenomenology is obtained due to the metastable nature of the critical state. We perform a detailed comparison with the analytical limits and we discuss their applicability for the actual geometry of superconducting conductors. We also define a loss factor which allow a more detailed analysis of the ac behavior than the ac loss. Finally, we compare the calculations with experiments, showing a significant qualitative and quantitative agreement without any fitting parameter.
This paper presents the analytical and numerical analysis of fluctuational dynamics of ac hysteretic SQUID. It has been demonstrated, that the most important parameter for the improvement of the hysteretic SQUID sensitivity is the ratio between the p ump and the characteristic frequencies but not their absolute values. The resonant behavior of signal-to-noise ratio as function of the pump frequency has been observed and the narrow area for the optimal pump frequency range is indicated.
152 - Yu.A. Genenko , H. Rauh 2009
Hysteretic ac losses in a thin, current-carrying superconductor strip located between two flat magnetic shields of infinite permeability are calculated using Beans model of the critical state. For the shields oriented parallel to the plane of the str ip, penetration of the self-induced magnetic field is enhanced, and the current dependence of the ac loss resembles that in an isolated superconductor slab, whereas for the shields oriented perpendicular to the plane of the strip, penetration of the self-induced magnetic field is impaired, and the current dependence of the ac loss is similar to that in a superconductor strip flanked by two parallel superconducting shields. Thus, hysteretic ac losses can strongly augment or, respectively, wane when the shields approach the strip.
170 - Y. A. Genenko , H. Rauh , S. Kurdi 2015
Numerical simulations of hysteretic ac losses in a tubular superconductor/paramagnet heterostructure subject to an oscillating transverse magnetic field are performed within the quasistatic approach, calling upon the COMSOL finite-element software pa ckage and exploiting magnetostatic-electrostatic analogues. It is shown that one-sided magnetic shielding of a thin, type-II superconducting tube by a coaxial paramagnetic support results in a slight increase of hysteretic ac losses as compared to those for a vacuum environment, when the support is placed inside; a spectacular shielding effect with a possible reduction of hysteretic ac losses by orders of magnitude, however, ensues, depending on the magnetic permeability and the amplitude of the applied magnetic field, when the support is placed outside.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا