ترغب بنشر مسار تعليمي؟ اضغط هنا

Mismatch between X-ray and emission-weighted temperatures in galaxy clusters: cosmological implications

104   0   0.0 ( 0 )
 نشر من قبل Pasquale Mazzotta
 تاريخ النشر 2004
  مجال البحث فيزياء
والبحث باللغة English
 تأليف E. Rasia




اسأل ChatGPT حول البحث

The thermal properties of hydrodynamical simulations of galaxy clusters are usually compared to observations by relying on the emission-weighted temperature T_ew, instead of on the spectroscopic X-ray temperature T_spec, which is obtained by actual observational data. In a recent paper Mazzotta et al. show that, if the cluster is thermally complex, T_ew fails at reproducing T_spec, and propose a new formula, the spectroscopic-like temperature, T_sl, which approximates T_spec better than a few per cent. By analyzing a set of hydrodynamical simulations of galaxy clusters, we find that T_sl is lower than T_ew by 20-30 per cent. As a consequence, the normalization of the M-T_sl relation from the simulations is larger than the observed one by about 50 per cent. If masses in simulated clusters are estimated by following the same assumptions of hydrostatic equilibrium and beta--model gas density profile, as often done for observed clusters, then the M-T relation decreases by about 40 per cent, and significantly reduces its scatter. Based on this result, we conclude that using the observed M-T relation to infer the amplitude of the power spectrum from the X-ray temperature function could bias low sigma_8 by 10-20 per cent. This may alleviate the tension between the value of sigma_8 inferred from the cluster number density and those from cosmic microwave background and large scale structure.



قيم البحث

اقرأ أيضاً

569 - Congyao Zhang 2014
Observations reveal that the peaks of the X-ray map and the Sunyaev-Zeldovich (SZ) effect map of some galaxy clusters are offset from each other. In this paper, we perform a set of hydrodynamical simulations of mergers of two galaxy clusters to inves tigate the spatial offset between the maxima of the X-ray and the SZ surface brightness of the merging clusters. We find that significantly large SZ-X-ray offsets (>100kpc) can be produced during the major mergers of galaxy clusters. The significantly large offsets are mainly caused by a `jump effect occurred between the primary and secondary pericentric passages of the two merging clusters, during which the X-ray peak may jump to the densest gas region located near the center of the small cluster, but the SZ peak remains near the center of the large one. Our simulations show that merging systems with higher masses and larger initial relative velocities may result in larger offset sizes and longer offset time durations; and only nearly head-on mergers are likely to produce significantly large offsets. We further investigate the statistical distribution of the SZ-X-ray offset sizes and find that (1) the number distribution of the offset sizes is bimodal with one peak located at low offsets ~0 and the other at large offsets ~350-450kpc/h, but the objects with intermediate offsets are scarce; and (2) the probabilities of the clusters in the mass range higher than 2x10^{14}Msun/h that have offsets larger than 20, 50, 200, 300, and 500kpc/h are 34.0%, 11.1%, 8.0%, 6.5%, and 2.0% respectively at z=0.7. The probability is sensitive to the underlying pairwise velocity distribution and the merger rate of clusters. Future observations on the offsets for a large number of clusters may put strong constraints on the cosmic velocity fields on the cluster scale and the cluster merger rate. (Abridged)
We explore the band dependence of the inferred X-ray temperature of the intracluster medium (ICM) for 192 well-observed galaxy clusters selected from the Chandra Data Archive. If the hot ICM is nearly isothermal in the projected region of interest, t he X-ray temperature inferred from a broad-band (0.7-7.0 keV) spectrum should be identical to the X-ray temperature inferred from a hard-band (2.0-7.0 keV) spectrum. However, if unresolved cool lumps of gas are contributing soft X-ray emission, the temperature of a best-fit single-component thermal model will be cooler for the broad-band spectrum than for the hard-band spectrum. Using this difference as a diagnostic, the ratio of best-fitting hard-band and broad-band temperatures may indicate the presence of cooler gas even when the X-ray spectrum itself may not have sufficient signal-to-noise to resolve multiple temperature components. To test this possible diagnostic, we extract X-ray spectra from core-excised annular regions for each cluster in our archival sample. We compare the X-ray temperatures inferred from single-temperature fits when the energy range of the fit is 0.7-7.0 keV (broad) and when the energy range is 2.0/(1+z)-7.0 keV (hard). We find that the hard-band temperature is significantly higher, on average, than the broad-band temperature. Upon further exploration, we find this temperature ratio is enhanced preferentially for clusters which are known merging systems. In addition, cool-core clusters tend to have best-fit hard-band temperatures that are in closer agreement with their best-fit broad-band temperatures. We show, using simulated spectra, that this diagnostic is sensitive to secondary cool components (TX = 0.5-3.0 keV) with emission measures >10-30% of the primary hot component.
The original abstract significantly exceeds the space available here, so heres a brief summary. The abstract is similar to the abstract of astro-ph/0111285 (ApJ, 567, 716) which describes the X-ray galaxy cluster sample HIFLUGCS, the X-ray luminosi ty--gravitational mass relation, the cluster mass function, and the derived cosmological constraints. Additionally, the fraction of the total gravitating mass in the universe which is contained in intracluster gas is quantified. Furthermore, physical properties of the cluster sample have been studied and analyses of relations between different cluster parameters (including the gas mass fraction, gas temperature, X-ray luminosity, gas mass, gravitational mass, beta, and core radius) are discussed. Also, results from an analysis of XMM-Newton performance verification phase data of Abell 1835 are described.
54 - Daisuke Nagai 2006
X-ray observations of galaxy clusters potentially provide powerful cosmological probes if systematics due to our incomplete knowledge of the intracluster medium (ICM) physics are understood and controlled. In this paper, we present mock Chandra analy ses of cosmological cluster simulations and assess X-ray measurements of galaxy cluster properties using a model and procedure essentially identical to that used in real data analysis. We show that reconstruction of three-dimensional ICM density and temperature profiles is excellent for relaxed clusters, but still reasonably accurate for unrelaxed systems. The total ICM mass is measured quite accurately (<6%) in all clusters, while the hydrostatic estimate of the gravitationally bound mass is biased low by about 5%-20% through the virial region, primarily due to additional pressure support provided by subsonic bulk motions in the ICM, ubiquitous in our simulations even in relaxed systems. Gas fraction determinations are therefore biased high; the bias increases toward cluster outskirts and depends sensitively on its dynamical state, but we do not observe significant trends of the bias with cluster mass or redshift. We also find that different average ICM temperatures, such as the X-ray spectroscopic Tspec and gas-mass-weighted Tmg, are related to each other by a constant factor with a relatively small object-to-object scatter and no systematic trend with mass, redshift or the dynamical state of clusters. We briefly discuss direct applications of our results for different cluster-based cosmological tests.
The UV spectra of Galactic and extragalactic sightlines often show OVI absorption lines at a range of redshifts, and from a variety of sources from the Galactic circumgalactic medium to AGN outflows. Inner shell OVI absorption is also observed in X-r ay spectra (at lambda=22.03 AA), but the column density inferred from the X-ray line was consistently larger than that from the UV line. Here we present a solution to this discrepancy for the z=0 systems. The OII K-beta line ^4S^0 --> (^3D)3p ^4P at 562.40 eV (==22.04 AA) is blended with the OVI K-alpha line in X-ray spectra. We estimate the strength of this OII line in two different ways and show that in most cases the OII line accounts for the entire blended line. The small amount of OVI equivalent width present in some cases has column density entirely consistent with the UV value. This solution to the OVI discrepancy, however, does not apply to the high column density systems like AGN outflows. We discuss other possible causes to explain their UV/X-ray mismatch. The OVI and OII lines will be resolved by gratings on-board the proposed mission Arcus and the concept mission Lynx and would allow detection of weak OVI lines not just at z=0 but also at higher redshift.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا