ترغب بنشر مسار تعليمي؟ اضغط هنا

Gamma-ray Polarimetry with Compton Telescope

339   0   0.0 ( 0 )
 نشر من قبل Hiroyasu Tajima
 تاريخ النشر 2004
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Compton telescope is a promising technology to achieve very high sensitivity in the soft gamma-ray band (0.1-10 MeV) by utilizing Compton kinematics. Compton kinematics also enables polarization measurement which will open new windows to study gamma-ray production mechanism in the universe. CdTe and Si semiconductor technologies are key technologies to realize the Compton telescope in which their high energy resolution is crucial for high angular resolution and background rejection capability. We have assembled a prototype module using a double-sided silicon strip detector and CdTe pixel detectors. In this paper, we present expected polarization performance of a proposed mission (NeXT/SGD). We also report results from polarization measurements using polarized synchrotron light and validation of EGS4 MC simulation.



قيم البحث

اقرأ أيضاً

The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is the first realization of a liquid xenon time projection chamber for Compton imaging of MeV gamma-ray sources in astrophysics. By measuring the energy deposit and the three spatial coordinates of individual gamma-ray scattering points, the location of the source in the sky is inferred with Compton kinematics reconstruction. The angular resolution is determined by the detectors energy and spatial resolutions, as well as by the separation in space between the first and second scattering. The imaging response of LXeGRIT was established with gamma-rays from radioactive sources, during calibration and integration at the Columbia Astrophysics Laboratory, prior to the 2000 balloon flight mission. In this paper we describe in detail the various steps involved in imaging sources with LXeGRIT and present experimental results on angular resolution and other parameters which characterize its performance as a Compton telescope.
112 - A.A. Moiseev 2015
The gamma-ray energy range from a few hundred keV to a few hundred MeV has remained largely unexplored, mainly due to the challenging nature of the measurements, since the pi- oneering, but limited, observations by COMPTEL on the Compton Gamma-Ray Ob servatory (1991-2000). This energy range is a transition region between thermal and nonthermal processes, and accurate measurements are critical for answering a broad range of astrophysical questions. We are developing a MIDEX-scale wide-aperture discovery mission, ComPair (Compton-Pair Production Space Telescope), to investigate the energy range from 200 keV to > 500 MeV with high energy and angular resolution and with sensitivity approaching a factor of 20-50 better than COMPTEL. This instrument will be equally capable to detect both Compton-scattering events at lower energy and pair-production events at higher energy. ComPair will build on the her- itage of successful space missions including Fermi LAT, AGILE, AMS and PAMELA, and will utilize well-developed space-qualified detector technologies including Si-strip and CdZnTe-strip detectors, heavy inorganic scintillators, and plastic scintillators.
133 - Mark Pearce 2011
The physical processes postulated to explain the high-energy emission mechanisms of compact astrophysical sources often yield polarised soft gamma rays (X-rays). PoGOLite is a balloon-borne polarimeter operating in the 25-80 keV energy band. The pola risation of incident photons is reconstructed using Compton scattering and photoelectric absorption in an array of phoswich detector cells comprising plastic and BGO scintillators, surrounded by a BGO side anticoincidence shield. The polarimeter is aligned to observation targets using a custom attitude control system. The maiden balloon flight is scheduled for summer 2011 from the Esrange Space Centre with the Crab and Cygnus X-1 as the primary observational targets.
Astrophysical polarization measurements in the soft gamma-ray band are becoming more feasible as detectors with high position and energy resolution are deployed. Previous work has shown that the minimum detectable polarization (MDP) of an ideal Compt on polarimeter can be improved by $sim 21%$ when an unbinned, maximum likelihood method is used instead of the standard approach of fitting a sinusoid to a histogram of azimuthal scattering angles. Here we outline a procedure for implementing this maximum likelihood approach for real, non-ideal polarimeters. As an example, we use the recent observation of GRB 160530A with the Compton Spectrometer and Imager. We find that the MDP for this observation is reduced by $20%$ when the maximum likelihood method is used instead of the standard method.
The future space-based GAMMA-400 gamma-ray telescope will operate onboard the Russian astrophysical observatory in a highly elliptic orbit during 7 years to observe Galactic plane, Galactic Center, Fermi Bubbles, Crab, Vela, Cygnus X, Geminga, Sun, a nd other regions and measure gamma- and cosmic-ray fluxes. Observations will be performed in the point-source mode continuously for a long time (~100 days). GAMMA-400 will have the unprecedented angular and energy resolutions better than the space-based and ground-based gamma-ray telescopes by a factor of 5-10. Excellent separation of gamma rays from cosmic-ray background, as well as electrons + positrons from protons will allow us to measure gamma rays in the energy range from ~20 MeV to several TeV and cosmic-ray electrons + positrons up to several tens TeV. GAMMA-400 observations will permit to resolve gamma rays from annihilation or decay of dark matter particles, identify many discrete sources, clarify the structure of extended sources, specify the data on cosmic-ray electron + positron spectra.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا