Different clinical elastography devices show different liver-stiffness values in the same subject, hindering comparison of values and establishment of system-independent thresholds for disease detection. Therefore, authorities request standardized phantoms that address the viscosity-related dispersion of stiffness over frequency. A linear polymerized polyacrylamide phantom (PAAm) was calibrated to the viscoelastic properties of healthy human liver in vivo. Shear-wave speed as a surrogate of stiffness was quantified between 5 Hz and 3000 Hz frequency-range by shear rheometry, ultrasound-based time-harmonic elastography, clinical MR elastography (MRE), and tabletop MRE. Imaging parameters for ultrasound were close to those of liver in vivo. Reproducibility, aging behavior and temperature dependency were assessed and fulfilled requirements for quantitative elastography. In addition, the phantom was used to characterize the frequency bandwidth of shear-wave speed of several clinical elastography methods. The liquid-liver phantom has favorable properties for standardization and development of liver elastography: first, it can be used across clinical and experimental elastography devices in ultrasound and MRI. Second, being a liquid, it can easily be adapted in size and shape to specific technical requirements, and by adding inclusions and scatterers. Finally, since the phantom is based on non-crosslinked linear PAA constituents, it is easy to produce, indicating potential widespread use among researchers and vendors to standardize liver-stiffness measurements.
In the framework of algebraic inversion, Magnetic Resonance Elastography (MRE) repeatability, reproducibility and robustness were evaluated on extracted shear velocities (or elastic moduli). The same excitation system was implemented at two sites equ
Objective: Realistic tissue-mimicking phantoms are essential for the development, the investigation and the calibration of medical imaging techniques and protocols. Because it requires taking both mechanical and imaging properties into account, the d
Segmentation of medical images is a challenging task owing to their complexity. A standard segmentation problem within Magnetic Resonance Imaging (MRI) is the task of labeling voxels according to their tissue type. Image segmentation provides volumet
The invasive measurement of the hepatic venous pressure gradient is still considered as the reference method to assess the severity of portal hypertension. Even though previous studies have shown that the liver stiffness measured by elastography coul
The quantification of liver fat as a diagnostic assessment of steatosis remains an important priority for noninvasive imaging systems. We derive a framework in which the unknown fat volume percentage can be estimated from a pair of ultrasound measure