ترغب بنشر مسار تعليمي؟ اضغط هنا

AstroSat/UVIT observations of IC4329A: Constraining the accretion disc inner radius

96   0   0.0 ( 0 )
 نشر من قبل Gulab C Dewangan
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present a study of far and near-ultraviolet emission from the accretion disk in a powerful Seyfert 1 galaxy IC4329A using observations performed with the Ultraviolet Imaging Telescope (UVIT) onboard AstroSat. These data provide the highest spatial resolution and deepest images of IC4329A in the far and near UV bands acquired to date. The excellent spatial resolution of the UVIT data has allowed us to accurately separate the extended emission from the host galaxy and the AGN emission in the far and near UV bands. We derive the intrinsic AGN flux after correcting for the Galactic and internal reddening, as well as for the contribution of emission lines from the broad and narrow-line regions. The intrinsic UV continuum emission shows a marked deficit compared to that expected from the standard models of the accretion disk around an estimated black hole mass of 1-2x10^8Msun when the disk extends to the innermost stable circular orbit. We find that the intrinsic UV continuum is fully consistent with the standard disk models, but only if the disk emits from distances larger than 80-150 gravitational radii.



قيم البحث

اقرأ أيضاً

We present five simultaneous UV/X-ray observations of IC4329A by AstroSat, performed over {a five-month} period. We utilize the excellent spatial resolution of the Ultra-Violet Imaging Telescope (UVIT) onboard AstroSat to reliably separate the intrin sic AGN flux from the host galaxy emission and to correct for the Galactic and internal reddening, as well as the contribution from the narrow and broad-line regions. We detect large-amplitude UV variability, which is unusual for a large black hole mass AGN, like IC4329A, over such a small period. In fact, the fractional variability amplitude is larger in the UV band than in the X-ray band. This demonstrates that the observed UV variability is intrinsic to the disk, and is not due to X-ray illumination. The joint X-ray spectral analyses of five SXT and LAXPC spectral data reveal a soft-X-ray excess component, a narrow iron-line (with no indication of a significant Compton hump), and a steepening power-law ($DeltaGammasim 0.21$) with increasing X-ray flux. The soft excess component could arise due to thermal Comptonization of the inner disk photons in a warm corona with $kT_esim 0.26$ keV. The UV emission we detect acts as the primary seed photons for the hot corona, which produces the broadband X-ray continuum. The X-ray spectral variability is well described by the cooling of this corona from $kT_esim42$ keV to $sim 32$ keV with increasing UV flux, while the optical depth remains constant at $tausim 2.3$.
We present the in-orbit performance and the first results from the ultra-violet Imaging telescope (UVIT) on ASTROSAT. UVIT consists of two identical 38cm coaligned telescopes, one for the FUV channel (130-180nm) and the other for the NUV (200-300nm) and VIS (320-550nm) channels, with a field of view of 28 $arcmin$. The FUV and the NUV detectors are operated in the high gain photon counting mode whereas the VIS detector is operated in the low gain integration mode. The FUV and NUV channels have filters and gratings, whereas the VIS channel has filters. The ASTROSAT was launched on 28th September 2015. The performance verification of UVIT was carried out after the opening of the UVIT doors on 30th November 2015, till the end of March 2016 within the allotted time of 50 days for calibration. All the on-board systems were found to be working satisfactorily. During the PV phase, the UVIT observed several calibration sources to characterise the instrument and a few objects to demonstrate the capability of the UVIT. The resolution of the UVIT was found to be about 1.4 - 1.7 $arcsec$ in the FUV and NUV. The sensitivity in various filters were calibrated using standard stars (white dwarfs), to estimate the zero-point magnitudes as well as the flux conversion factor. The gratings were also calibrated to estimate their resolution as well as effective area. The sensitivity of the filters were found to be reduced up to 15% with respect to the ground calibrations. The sensitivity variation is monitored on a monthly basis. UVIT is all set to roll out science results with its imaging capability with good resolution and large field of view, capability to sample the UV spectral region using different filters and capability to perform variability studies in the UV.
158 - Amit Kumar 2012
Ultra Violet Imaging Telescope on ASTROSAT Satellite mission is a suite of Far Ultra Violet (FUV 130 to 180 nm), Near Ultra Violet (NUV 200 to 300 nm) and Visible band (VIS 320 to 550nm) imagers. ASTROSAT is the first multi wavelength mission of INDI A. UVIT will image the selected regions of the sky simultaneously in three channels and observe young stars, galaxies, bright UV Sources. FOV in each of the 3 channels is about 28 arc-minute. Targeted angular resolution in the resulting UV images is better than 1.8 arc-second (better than 2.0 arc-second for the visible channel). Two identical co-aligned telescopes (T1, T2) of Ritchey-Chretien configuration (Primary mirror of 375 mm diameter) collect celestial radiation and feed to the detector system via a selectable filter on a filter wheel mechanism; gratings are available in filter wheels of FUV and NUV channels for slit-less low resolution spectroscopy. The detector system for each of the 3 channels is generically identical. One of the telescopes images in the FUV channel, while the other images in NUV and VIS channels. Images from VIS channel are also used for measuring drift for reconstruction of images on ground through shift and add algorithm, and to reconstruct absolute aspect of the images. Adequate baffling has been provided for reducing scattered background from the Sun, earth albedo and other bright objects. One time open-able mechanical cover on each telescope also works as a Sun-shield after deployment. We are presenting here the overall (mechanical, optical and electrical) design of the payload.
The temporal behaviour of X-rays from some AGN and microquasars is thought to arise from the rapid collapse of the hot, inner parts of their accretion discs. The collapse can occur over the radial infall timescale of the inner accretion disc. However , estimates of this timescale are hindered by a lack of knowledge of the operative viscosity in the collisionless plasma comprising the inner disc. We use published simulation results for cosmic ray diffusion through turbulent magnetic fields to arrive at a viscosity prescription appropriate to hot accretion discs. We construct simplified disc models using this viscosity prescription and estimate disc collapse timescales for 3C 120, 3C 111, and GRS 1915+105. The Shakura-Sunyaev {alpha} parameter resulting from our model ranges from 0.02 to 0.08. Our inner disc collapse timescale estimates agree well with those of the observed X-ray dips. We find that the collapse timescale is most sensitive to the outer radius of the hot accretion disc.
Ultraviolet Imaging Telescope (UVIT) is one of the payloads onboard AstroSat, Indias first multi-wavelength Astronomy mission. UVIT is primarily designed to make high resolution images in wide field, in three wavelength channels simultaneously: FUV ( 130 - 180 nm), NUV (200 - 300 nm) and VIS (320 - 550 nm). The intensified imagers used in UVIT suffer from distortions, and a correction is necessary for these to achieve good astrometry. In this article we describe the methodology and calculations used to estimate the distortions in ground calibrations.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا