ترغب بنشر مسار تعليمي؟ اضغط هنا

Position uncertainties of AGATA pulse-shape analysis estimated via the boostrapping method

136   0   0.0 ( 0 )
 نشر من قبل Marco Siciliano
 تاريخ النشر 2021
  مجال البحث
والبحث باللغة English




اسأل ChatGPT حول البحث

The unprecedented capabilities of state-of-the-art segmented germanium-detector arrays, such as AGATA and GRETA, derive from the possibility of performing pulse-shape analysis. The comparison of the net- and transient-charge signals with databases via grid-search methods allows the identification of the $gamma$-ray interaction points within the segment volume. Their precise determination is crucial for the subsequent reconstruction of the $gamma$-ray paths within the array via tracking algorithms, and hence the performance of the spectrometer. In this paper the position uncertainty of the deduced interaction point is investigated using the bootstrapping technique applied to $^{60}$Co radioactive-source data. General features of the extracted position uncertainty are discussed as well as its dependence on various quantities, e.g. the deposited energy, the number of firing segments and the segment geometry.



قيم البحث

اقرأ أيضاً

Compton scattering is one of the dominant interaction processes in germanium for photons with an energy of around two MeV. If a photon scatters only once inside a germanium detector, the resulting event contains only one electron which normally depos its its energy within a mm range. Such events are similar to Ge-76 neutrinoless double beta-decay events with just two electrons in the final state. Other photon interactions like pair production or multiple scattering can result in events composed of separated energy deposits. One method to identify the multiple energy deposits is the use of timing information contained in the electrical response of a detector or a segment of a detector. The procedures developed to separate single- and multiple-site events are tested with specially selected event samples provided by an 18-fold segmented prototype germanium detector for Phase II of the GERmanium Detector Array, GERDA. The single Compton scattering, i.e. single-site, events are tagged by coincidently detecting the scattered photon with a second detector positioned at a defined angle. A neural network is trained to separate such events from events which come from multi-site dominated samples. Identification efficiencies of ~80% are achieved for both single- and multi-site events.
The method of pulse-shape analysis (PSA) for particle identification (PID) was applied to a double-sided silicon strip detector (DSSD) with a strip pitch of 300 {mu}m. We present the results of test measurements with particles from the reactions of a 70 MeV 12C beam impinging on a mylar target. Good separation between protons and alpha particles down to 3 MeV has been obtained when excluding the interstrip events of the DSSD from the analysis.
186 - L.Bardelli , M.Bini , P.G.Bizzeti 2007
The light output, $alpha/beta$ ratio, and pulse shape have been investigated at $-25^circ$ C with PbWO$_4$ crystal scintillators undoped, and doped by F, Eu, Mo, Gd and S. The fast $0.01-0.06 mu$s and middle $0.1-0.5 mu$s components of scintillation decay were observed for all the samples. Slow components of scintillation signal with the decay times $1-3 mu$s and $13-28 mu$s with the total intensity up to $approx50%$ have been recognized for several samples doped by Molybdenum. We found some indications of a pulse-shape discrimination between $alpha$ particles and $gamma$ quanta with PbWO$_4$ (Mo doped) crystal scintillators.
Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator detector, and a BaF2 detector was used to collect waveforms with a 100 Ms/s, 14 bit sampling ADC. Three identical ADCs were combined to increase the sampling frequency to 300 Ms/s. Four different digital pulse-shape analysis algorithms were developed and compared to each other and to data obtained with an analogue neutron-gamma discrimination unit. Two of the digital algorithms were based on the charge comparison method, while the analogue unit and the other two digital algorithms were based on the zero-crossover method. Two different figure-of-merit parameters, which quantify the neutron-gamma discrimination properties, were evaluated for all four digital algorithms and for the analogue data set. All of the digital algorithms gave similar or better figure-of-merit values than what was obtained with the analogue setup. A detailed study of the discrimination properties as a function of sampling frequency and bit resolution of the ADC was performed. It was shown that a sampling ADC with a bit resolution of 12 bits and a sampling frequency of 100 Ms/s is adequate for achieving an optimal neutron-gamma discrimination for pulses having a dynamic range for deposited neutron energies of 0.3-12 MeV. An investigation of the influence of the sampling frequency on the time resolution was made. A FWHM of 1.7 ns was obtained at 100 Ms/s.
Events near the cathode and anode surfaces of a coplanar grid CdZnTe detector are identifiable by means of the interaction depth information encoded in the signal amplitudes. However, the amplitudes cannot be used to identify events near the lateral surfaces. In this paper a method is described to identify lateral surface events by means of their pulse shapes. Such identification allows for discrimination of surface alpha particle interactions from more penetrating forms of radiation, which is particularly important for rare event searches. The effectiveness of the presented technique in suppressing backgrounds due to alpha contamination in the search for neutrinoless double beta decay with the COBRA experiment is demonstrated.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا