ترغب بنشر مسار تعليمي؟ اضغط هنا

Test of pulse shape analysis using single Compton scattering events

168   0   0.0 ( 0 )
 نشر من قبل Xiang Liu
 تاريخ النشر 2007
  مجال البحث
والبحث باللغة English




اسأل ChatGPT حول البحث

Compton scattering is one of the dominant interaction processes in germanium for photons with an energy of around two MeV. If a photon scatters only once inside a germanium detector, the resulting event contains only one electron which normally deposits its energy within a mm range. Such events are similar to Ge-76 neutrinoless double beta-decay events with just two electrons in the final state. Other photon interactions like pair production or multiple scattering can result in events composed of separated energy deposits. One method to identify the multiple energy deposits is the use of timing information contained in the electrical response of a detector or a segment of a detector. The procedures developed to separate single- and multiple-site events are tested with specially selected event samples provided by an 18-fold segmented prototype germanium detector for Phase II of the GERmanium Detector Array, GERDA. The single Compton scattering, i.e. single-site, events are tagged by coincidently detecting the scattered photon with a second detector positioned at a defined angle. A neural network is trained to separate such events from events which come from multi-site dominated samples. Identification efficiencies of ~80% are achieved for both single- and multi-site events.



قيم البحث

اقرأ أيضاً

Events near the cathode and anode surfaces of a coplanar grid CdZnTe detector are identifiable by means of the interaction depth information encoded in the signal amplitudes. However, the amplitudes cannot be used to identify events near the lateral surfaces. In this paper a method is described to identify lateral surface events by means of their pulse shapes. Such identification allows for discrimination of surface alpha particle interactions from more penetrating forms of radiation, which is particularly important for rare event searches. The effectiveness of the presented technique in suppressing backgrounds due to alpha contamination in the search for neutrinoless double beta decay with the COBRA experiment is demonstrated.
The method of pulse-shape analysis (PSA) for particle identification (PID) was applied to a double-sided silicon strip detector (DSSD) with a strip pitch of 300 {mu}m. We present the results of test measurements with particles from the reactions of a 70 MeV 12C beam impinging on a mylar target. Good separation between protons and alpha particles down to 3 MeV has been obtained when excluding the interstrip events of the DSSD from the analysis.
The unprecedented capabilities of state-of-the-art segmented germanium-detector arrays, such as AGATA and GRETA, derive from the possibility of performing pulse-shape analysis. The comparison of the net- and transient-charge signals with databases vi a grid-search methods allows the identification of the $gamma$-ray interaction points within the segment volume. Their precise determination is crucial for the subsequent reconstruction of the $gamma$-ray paths within the array via tracking algorithms, and hence the performance of the spectrometer. In this paper the position uncertainty of the deduced interaction point is investigated using the bootstrapping technique applied to $^{60}$Co radioactive-source data. General features of the extracted position uncertainty are discussed as well as its dependence on various quantities, e.g. the deposited energy, the number of firing segments and the segment geometry.
We report on the highest precision yet achieved in the measurement of the polarization of a low energy, $mathcal{O}$(1 GeV), electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall~C at Jefferson Lab. A number of technical innovations were necessary, including a novel method for precise control of the laser polarization in a cavity and a novel diamond micro-strip detector which was able to capture most of the spectrum of scattered electrons. The data analysis technique exploited track finding, the high granularity of the detector and its large acceptance. The polarization of the $180~mu$A, $1.16$~GeV electron beam was measured with a statistical precision of $<$~1% per hour and a systematic uncertainty of 0.59%. This exceeds the level of precision required by the qweak experiment, a measurement of the vector weak charge of the proton. Proposed future low-energy experiments require polarization uncertainty $<$~0.4%, and this result represents an important demonstration of that possibility. This measurement is also the first use of diamond detectors for particle tracking in an experiment.
69 - Y. Ashida , H. Nagata , Y. Koshio 2018
Fast neutrons are a large background to measurements of gamma-rays emitted from excited nuclei, such that detectors which can efficiently distinguish between the two are essential. In this paper we describe the separation of gamma-rays from neutrons with the pulse shape information of the CsI(Tl) scintillator, using a fast neutron beam and several gamma-ray sources. We find that a figure of merit optimized for this separation takes on large and stable values (nearly 4) between 5 and 10 MeV of electron equivalent deposited energy, the region of most interest to the study of nuclear de-excitation gamma-rays. Accordingly this work demonstrates the ability of CsI(Tl) scintillators to reject neutron backgrounds to gamma-ray measurements at these energies.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا