ترغب بنشر مسار تعليمي؟ اضغط هنا

Mechanics of mineralized collagen fibrils upon transient loads

162   0   0.0 ( 0 )
 نشر من قبل Mario Milazzo
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Collagen is a key structural protein in the human body, which undergoes mineralization during the formation of hard tissues. Earlier studies have described the mechanical behavior of bone at different scales highlighting material features across hierarchical structures. Here we present a study that aims to understand the mechanical properties of mineralized collagen fibrils upon tensile/compressive transient loads, investigating how the kinetic energy propagates and it is dissipated at the molecular scale, thus filling a gap of knowledge in this area. These specific features are the mechanisms that Nature has developed to passively dissipate stress and prevent structural failures. In addition to the mechanical properties of the mineralized fibrils, we observe distinct nanomechanical behaviors for the two regions (i.e., overlap and gap) of the D-period to highlight the effect of the mineralization. We notice decreasing trends for both wave speeds and Young s moduli over input velocity with a marked strengthening effect in the gap region due to the accumulation of the hydroxyapatite. In contrast, the dissipative behavior is not affected by either loading conditions or the mineral percentage, showing a stronger dampening effect upon faster inputs compatible to the bone behavior at the macroscale. Our results improve the understanding of mineralized collagen composites unveiling the energy dissipative behavior of such materials. This impacts, besides the physiology, the design and characterization of new bioinspired composites for replacement devices (e.g., prostheses for sound transmission or conduction) and for optimized structures able to bear transient loads, e.g., impact, fatigue, in structural applications.



قيم البحث

اقرأ أيضاً

Bone is mineralized tissue constituting the skeletal system, supporting and protecting body organs and tissues. At the molecular level, mineralized collagen fibril is the basic building block of bone tissue, and hence, understanding bone properties d own to fundamental tissue structures enables to better identify the mechanisms of structural failures and damages. While efforts have focused on the study of the micro- and macro-scale viscoelasticity related to bone damage and healing based on creep, mineralized collagen has not been explored on a molecular level. We report a study that aims at systematically exploring the viscoelasticity of collagenous fibrils with different mineralization levels. We investigate the dynamic mechanical response upon cyclic and impulsive loads to observe the viscoelastic phenomena from either shear or extensional strains via molecular dynamics. We perform a sensitivity analysis with several key benchmarks: intrafibrillar mineralization percentage, hydration state, and external load amplitude. Our results show a growth of the dynamic moduli with an increase of mineral percentage, pronounced at low strains. When intrafibrillar water is present, the material softens the elastic component but considerably increases its viscosity, especially at high frequencies. This behaviour is confirmed from the material response upon impulsive loads, in which water drastically reduces the relaxation times throughout the input velocity range by one order of magnitude, with respect to the dehydrated counterparts. We find that upon transient loads, water has a major impact on the mechanics of mineralized fibrillar collagen, being able to improve the capability of the tissue to passively and effectively dissipate energy, especially after fast and high-amplitude external loads.
Collagen is the key protein of connective tissue (i.e., skin, tendons and ligaments, cartilage, among others) accounting for 25% to 35% of the whole-body protein content, and entitled of conferring mechanical stability. This protein is also a fundame ntal building block of bone due to its excellent mechanical properties together with carbonated hydroxyapatite minerals. While the mechanical resilience and viscoelasticity have been studied both in vitro and in vivo from the molecule to tissue level, wave propagation properties and energy dissipation have not yet been deeply explored, in spite of being crucial to understand the vibration dynamics of collagenous structures (e.g., eardrum, cochlear membranes) upon impulsive loads. By using a bottom-up atomistic modelling approach, here we study a collagen peptide under two distinct impulsive displacement loads, including longitudinal and transversal inputs. Using a one-dimensional string model as a model system, we investigate the roles of hydration and load direction on wave propagation along the collagen peptide and the related energy dissipation. We find that wave transmission and energy-dissipation strongly depend on the loading direction. Also, the hydrated collagen peptide can dissipate five times more energy than dehydrated one. Our work suggests a distinct role of collagen in term of wave transmission of different tissues such as tendon and eardrum. This study can step towards understanding the mechanical behaviour of collagen upon transient loads, impact loading and fatigue, and designing biomimetic and bio-inspired materials to replace specific native tissues such as the tympanic membrane.
In medicolegal situations, the consequences of a stabbing incident are described in terms that are qualitative without being quantitative. Here, the mechanical variables involved in knife-tissue penetration events are used to determine the parameters needed to be controlled in a measurement device. They include knife geometry, in-plane mechanical stress state of skin, angle and speed of knife penetration, and underlying fascia. Four household knives with different geometries were used. Synthetic materials were used to simulate the response of skin, fat and cartilage: polyurethane, foam, and ballistic soap, respectively. The force and energy applied by the blade and the skin displacement were used to identify skin penetration. The skin tension is shown to have a direct effect on the force and energy for knife penetration and on the depth of displacement of the simulant prior to penetration: larger levels of in-plane tension in the skin are associated with lower penetration forces, energies and displacements. Less force and energy are required for puncture when the blade is parallel to a direction of greater skin tension than when perpendicular. Surprisingly, evidence suggests that the quality control processes used to manufacture knives fail to produce consistently uniform blade points in nominally identical knives, leading to penetration forces which can vary widely.
We consider the problem of the nonlinear response of a Rayleigh beam to the passage of a train of forces moving with stochastic velocity. The Fourier transform and the theory of residues is used to estimate the mean-square amplitude of the beam, whil e the stochastic averaging method gives the stationary probability density function of the oscillations amplitude. The analysis shows that the effect of the load random velocities is highly nonlinear, leading to a nonmonotonic behavior of the mean amplitude versus the intensity of the stochastic term and of the load weight. The analytic approach is also checked with numerical simulations. The effect of loads number on the system response is numerically investigated.
134 - Kai Wu , Diqing Su , Renata Saha 2020
Magnetic particle spectroscopy (MPS), also called magnetization response spectroscopy, is a novel measurement tool derived from magnetic particle imaging (MPI). It can be interpreted as a zero-dimensional version of MPI scanner. MPS was primarily des igned for characterizing superparamagnetic iron oxide nanoparticles (SPIONs) regarding their applicability for MPI. In recent years, it has evolved into an independent, versatile, highly sensitive, inexpensive platform for biological and biomedical assays, cell labeling and tracking, and blood analysis. MPS has also developed into an auxiliary tool for magnetic imaging and hyperthermia by providing high spatial and temporal mappings of temperature and viscosity. Furthermore, other MPS-based applications are being explored such as magnetic fingerprints for product tracking and identification in supply chains. There are a variety of novel MPS-based applications being reported and demonstrated by many groups. In this short review, we highlighted some of the representative applications based on MPS platform, thereby providing a roadmap of this technology and our insights for researchers in this area.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا