ترغب بنشر مسار تعليمي؟ اضغط هنا

Hidden Photon Dark Matter in the Light of XENON1T and Stellar Cooling

139   0   0.0 ( 0 )
 نشر من قبل Lennert J. Thormaehlen
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The low-energy electronic recoil spectrum in XENON1T provides an intriguing hint for potential new physics. At the same time, observations of horizontal branch stars favor the existence of a small amount of extra cooling compared to the one expected from the Standard Model particle content. In this note, we argue that a hidden photon with a mass of $sim 2.5$ keV and a kinetic mixing of $sim 10^{-15}$ allows for a good fit to both of these excesses. In this scenario, the signal detected in XENON1T is due to the absorption of hidden photon dark matter particles, whereas the anomalous cooling of horizontal branch stars arises from resonant production of hidden photons in the stellar interior.



قيم البحث

اقرأ أيضاً

122 - Manoranjan Dutta 2021
We propose a self-interacting inelastic dark matter (DM) scenario as a possible origin of the recently reported excess of electron recoil events by the XENON1T experiment. Two quasi-degenerate Majorana fermion DM interact within themselves via a ligh t hidden sector massive gauge boson and with the standard model particles via gauge kinetic mixing. We also consider an additional long-lived singlet scalar which helps in realising correct dark matter relic abundance via a hybrid setup comprising of both freeze-in and freeze-out mechanisms. While being consistent with the required DM phenomenology along with sufficient self-interactions to address the small scale issues of cold dark matter, the model with GeV scale DM can explain the XENON1T excess via inelastic down scattering of heavier DM component into the lighter one. All these requirements leave a very tiny parameter space keeping the model very predictive for near future experiments.
90 - Debasish Borah 2021
We propose a self-interacting boosted dark matter (DM) scenario as a possible origin of the recently reported excess of electron recoil events by the XENON1T experiment. The Standard Model has been extended with two vector-like fermion singlets charg ed under a dark $U(1)_D$ gauge symmetry to describe the dark sector. While the presence of light vector boson mediator leads to sufficient DM self-interactions to address the small scale issues of cold dark matter, the model with GeV scale DM can explain the XENON1T excess via scattering of boosted DM component with electrons at the detector. The requirement of large annihilation rate of heavier DM into the lighter one for sufficient boosted DM flux leads to suppressed thermal relic abundance. A hybrid setup of thermal and non-thermal contribution from late decay of a scalar can lead to correct relic abundance. All these requirements leave a very tiny parameter space for sub-GeV DM keeping the model very predictive for near future experiments.
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target o f the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented.
We consider a novel scenario of dark photon-mediated inelastic dark matter to explain the white dwarf cooling excess suggested by its luminosity function, and the excess in electron recoil events at XENON1T. In the Sun, the dark photon $A$ is produce d mainly via thermal processes, and the heavier dark matter $chi_2$ is produced by the scattering of halo dark matter $chi_1$ with electrons. The XENON1T signal arises primarily by solar $A$ scattering, and $A$ emission by white dwarfs accommodates the extra cooling while maintaining consistency with other stellar cooling observations. A tritium component in the XENON1T detector is also required. We show for parameters that explain the XENON1T data, but not the white dwarf cooling anomaly, that a second signal peak may be buried in the XENON1T data and revealable at XENONnT. However, the parameters that give the double peak in the spectrum are incompatible with constraints from horizontal branch stars.
An excess of low-energy electronic recoil events over known backgrounds was recently observed in the XENON1T detector, where $285$ events are observed compared to an expected $232 pm 15$ events from the background-only fit to the data in the energy r ange 1-7 keV. This could be due to the beta decay of an unexpected tritium component, or possibly to new physics. One plausible new physics explanation for the excess is absorption of hidden photon dark matter relics with mass around $2.8$ keV and kinetic mixing of about $10^{-15}$, which can also explain cooling excesses in horizontal-branch (HB) stars. Such small gauge boson masses and couplings can naturally arise from type-IIB low scale string theory. We provide a fit of the XENON1T excess in terms of a minimal low scale type-IIB string theory parameter space and present some benchmark points which provide a good fit to the data. It is also demonstrated how the required transformation properties of the massless spectrum are obtained in intersecting D-brane models.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا