ترغب بنشر مسار تعليمي؟ اضغط هنا

Muon deficit in air shower simulations estimated from AGASA muon measurements

135   0   0.0 ( 0 )
 نشر من قبل Flavia Gesualdi
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

In this work, direct measurements of the muon density at $1000,textrm{m}$ from the shower axis obtained by the Akeno Giant Air Shower Array (AGASA) are analysed. The selected events have zenith angles $theta leq 36^{textrm{o}}$ and reconstructed energies in the range $18.83,leq,log_{10}(E_{R}/textrm{eV}),leq,19.46$. These are compared to the predictions corresponding to proton, iron, and mixed composition scenarios obtained by using the high-energy hadronic interaction models EPOS-LHC, QGSJetII-04, and Sibyll2.3c. The mass fractions of the mixed composition scenarios are taken from the fits to the depth of the shower maximum distributions performed by the Pierre Auger Collaboration. The cross-calibrated energy scale from the Spectrum Working Group [D. Ivanov, for the Pierre Auger Collaboration and the Telescope Array Collaboration, PoS(ICRC2017) 498 (2017)] is used to combine results from different experiments. The analysis shows that the AGASA data are compatible with a heavier composition with respect to the one predicted by the mixed composition scenarios. Interpreting this as a muon deficit in air shower simulations, the incompatibility is quantified. The muon density obtained from AGASA data is greater than that of the mixed composition scenarios by a factor of $1.49pm0.11,textrm{(stat)}pm0.18,textrm{(syst)}$, $1.54pm0.12,textrm{(stat)}pm0.18,textrm{(syst)}$, and $1.66pm0.13,textrm{(stat)}pm0.20,textrm{(syst)}$ for EPOS-LHC, Sibyll2.3c, and QGSJetII-04, respectively.



قيم البحث

اقرأ أيضاً

We present a meta-analysis of recent muon density measurements made by eight air shower experiments which cover shower energies ranging from PeV to tens of EeV regarding the muon puzzle in extensive air showers. Some experimental analyses reported de viations between recorded and simulated muon densities in extensive air showers, and others reported no discrepancies. Comparisons between experiments were made using a universal reference scale based on the relative difference to simulated proton and iron initiated air showers. We have applied a cross-calibration of energy scales between experiments based on the isotropic flux of cosmic rays as a reference. Above 10 PeV, most experimental data show a muon excess with respect to simulated air showers, including those performed with the recent post-LHC high-energy interaction models. The discrepancy increases with the shower energy with a slope 8 sigma away from the predictions by EPOS-LHC and QGSJet-II.04. The effect of measurements being made at different zenith angles and energy threshold of muons across different experiments will be addressed.
Over the last two decades, various experiments have measured muon densities in extensive air showers over several orders of magnitude in primary energy. While some experiments observed differences in the muon densities between simulated and experimen tally measured air showers, others reported no discrepancies. We will present an update of the meta-analysis of muon measurements from nine air shower experiments, covering shower energies between a few PeV and tens of EeV and muon threshold energies from a few 100 MeV to about 10 GeV. In order to compare measurements from different experiments, their energy scale was cross-calibrated and the experimental data has been compared using a universal reference scale based on air shower simulations. Above 10 PeV, we find a muon excess with respect to simulations for all hadronic interaction models, which is increasing with shower energy. For EPOS-LHC and QGSJet-II.04 the significance of the slope of the increase is analyzed in detail under different assumptions of the individual experimental uncertainties.
The number of muons in extensive air showers predicted using LHC-tuned hadronic interaction models, such as EPOS-LHC and QGSJetII-04, is smaller than observed in showers recorded by leading cosmic ray experiments. In this paper, we present a new meth od to derive muon rescaling factors by analyzing reconstructions of simulated showers. The z-variable used (difference of initially simulated and reconstructed total signal in detectors) is connected to the muon signal and is roughly independent of the zenith angle but depends on the mass of primary cosmic ray. The performance of the method is tested using Monte Carlo shower simulations for the hybrid detector of the Pierre Auger Observatory. Having an individual z-value from each simulated hybrid event, the corresponding signal at 1000 m from the shower axis, and using a parametrization of the muon fraction in simulated showers, we can calculate the multiplicative rescaling parameters of the muon signals in the ground detector even for an individual event. We can also study its dependence as a function of zenith angle and the mass of primary cosmic ray. This gives a possibility not only to test/calibrate the hadronic interaction models, but also to derive the $beta$-exponent, describing an increase of the number of muons as a function of primary energy and mass of the cosmic ray. Detailed simulations show dependence of the $beta$-exponent on hadronic interaction properties, thus the determination of this parameter is important for understanding the muon deficit problem.
At ground level, the azimuthal distribution of muons in inclined Extensive Air Showers (EAS) is asymmetric, mainly due to geometric effects. Several EAS observables sensitive to the primary particle mass, are constructed after mapping the density of secondary particles from the ground plane to the shower plane (perpendicular to the shower axis). A simple orthogonal projection of the muon coordinates onto this plane distorts the azimuthal symmetry in the shower plane. Using CORSIKA simulations, we correct for this distortion by projecting each muon onto the normal plane following its incoming direction, taking also into account the attenuation probability. We show that besides restoring the azimuthal symmetry of muons density around the shower axis, the application of this procedure has a significant impact on the reconstruction of the distribution of the muon production depth and of its maximum, $X_{rm max}^{mu}$, which is an EAS observable sensitive to the primary particle mass. Our results qualitatively suggest that not including it in the reconstruction process of $X_{rm max}^{mu}$ may introduce a bias in the results obtained by analyzing the actual data on the basis of Monte Carlo simulations.
Despite the significant experimental effort made in the last decades, the origin of the ultra-high energy cosmic rays is still largely unknown. Key astrophysical information to identify where these energetic particles come from is provided by their c hemical composition. It is well known that a very sensitive tracer of the primary particle type is the muon content of the showers generated by the interaction of the cosmic rays with air molecules. We introduce a likelihood function to reconstruct particle densities using segmented detectors with time resolution. As an example of this general method, we fit the muon distribution at ground level using an array of counters like AMIGA, one of the Pierre Auger Observatory detectors. For this particular case we compare the reconstruction performance against a previous method. With the new technique, more events can be reconstructed than before. In addition the statistical uncertainty of the measured number of muons is reduced, allowing for a better discrimination of the cosmic ray primary mass.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا