The microwave cavity perturbation method is often used to determine material parameters (electric permittivity and magnetic permeability) at high frequencies and it relies on measurement of the resonator parameters. We present a method to determine the $Q$-factor and resonance frequency of microwave resonators which is conceptually simple but provides a sensitivity for these parameters which overcomes those of existing methods by an order of magnitude. The microwave resonator is placed in a feedback resonator setup, where the output of an amplifier is connected to its own input with the resonator as a band pass filter. After reaching steady-state oscillation, the feedback circuit is disrupted by a fast microwave switch and the transient signal, which emanates from the resonator, is detected using down-conversion. The Fourier transform of the resulting time-dependent signal yields directly the resonance profile of the resonator. Albeit the method is highly accurate, this comes with a conceptual simplicity, ease of implementation and lower circuit cost. We compare existing methods for this type of measurement to explain the sensitivity of the present technique and we also make a prediction for the ultimate sensitivity for the resonator $Q$ and $f_0$ determination.



قيم البحث

اقرأ أيضاً

Thermodynamic fluctuations in mechanical resonators cause uncertainty in their frequency measurement, fundamentally limiting performance of frequency-based sensors. Recently, integrating nanophotonic motion readout with micro- and nano-mechanical res onators allowed practical chip-scale sensors to routinely operate near this limit in high-bandwidth measurements. However, the exact and general expressions for either thermodynamic frequency measurement uncertainty or efficient, real-time frequency estimators are not well established, particularly for fast and weakly-driven resonators. Here, we derive, and numerically validate, the Cramer-Rao lower bound (CRLB) and an efficient maximum-likelihood estimator for the frequency of a classical linear harmonic oscillator subject to thermodynamic fluctuations. For a fluctuating oscillator without external drive, the frequency Allan deviation calculated from simulated resonator motion data agrees with the derived CRLB $sigma_f = {1 over 2pi}sqrt{Gamma over 2tau}$ for averaging times $tau$ below, as well as above, the relaxation time $1overGamma$. The CRLB approach is general and can be extended to driven resonators, non-negligible motion detection imprecision, as well as backaction from a continuous linear quantum measurement.
Absorbed power of nanoparticles during magnetic hyperthermia can be well determined from changes in the quality factor ($Q$ factor) of a resonator, in which the radiofrequency (RF) absorbent is placed. We present an order of magnitude improvement in the $Q$ factor measurement accuracy over conventional methods by studying the switch-on and off transient signals of the resonators. A nuclear magnetic resonance (NMR) console is ideally suited to acquire the transient signals and it also allows to employ the so-called pulse phase-cycling to remove transient artifacts. The improved determination of the absorbed power is demonstrated on various resonators in the 1-30 MHz range including standard solenoids and also a birdcage resonator. This leads to the possibility to detect minute amounts of ferrite nanoparticles which are embedded in the body and also the amount of the absorbed power. We demonstrate this capability on a phantom study, where the exact location of an embedded ferrite is clearly detected.
The trade-off between radiation efficiency and antenna bandwidth, expressed in terms of Q-factor, for small antennas is formulated as a multi-objective optimization problem in current distributions of predefined support. Variants on the problem are c onstructed to demonstrate the consequences of requiring a self-resonant current as opposed to one tuned by an external reactance. The resulting Pareto-optimal sets reveal the relative cost of valuing low radiation Q-factor over high efficiency, the cost in efficiency to require a self-resonant current, the effects of lossy parasitic loading, and other insights.
We report on the first experimental demonstration of terahertz (THz) whispering-gallery modes (WGMs) with an ultra high quality (Q) factor of $1.5 times {10}^{4}$ at 0.62THz. The WGMs are observed in a high resistivity float zone silicon (HRFZ-Si) sp herical resonator coupled to a sub-wavelength silica waveguide. A detailed analysis of the coherent continuous wave (CW) THz spectroscopy measurements combined with a numerical model based on Mie-Debye-Aden-Kerker (MDAK) theory allows to unambiguously identify the observed higher order radial THz WGMs.
Recent demonstrations of ultracoherent nanomechanical resonators introduce the prospect of new protocols for solid state sensing applications. Here, we propose to use two coupled ultracoherent resonator modes on a Si$_3$N$_4$ membrane for the detecti on of small nuclear spin ensembles. To this end, we employ parametric frequency conversion between nondegenerate modes. The nondegenerate modes result from coupled degenerate resonators, and the parametric conversion is mediated by periodic