ترغب بنشر مسار تعليمي؟ اضغط هنا

Fast X-ray detector system with simultaneous measurement of timing and energy for a single photon

76   0   0.0 ( 0 )
 نشر من قبل Takahiko Masuda Dr.
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We developed a fast X-ray detector system for nuclear resonant scattering (NRS) experiments. Our system employs silicon avalanche photo-diode (Si-APD) as a fast X-ray sensor. The system is able to acquire both timing and energy of a single X-ray photon simultaneously in a high rate condition, $10^6$ counts per second for one Si-APD. The performance of the system was investigated in SPring-8, a synchrotron radiation facility in Japan. Good time resolution of SI{120}{ps} (FWHM) was achieved with a slight tail distribution in the time spectrum by a level of $10^{-9}$ at 1 ns apart from the peak. Using this system, we successfully observed the NRS from the 26.27-keV level of mercury-201, which has a half-life of $630 pm 50$ ps. We also demonstrated the reduction of background events caused by radioactive decays in a radioactive sample by discriminating photon energy.



قيم البحث

اقرأ أيضاً

66 - X. Zhang , Q. Wang , 2016
We fabricated a superconducting single X-ray photon detector based on W0.8Si0.2, and we characterized its basic detection performance for keV-photons at different temperatures. The detector has a critical temperature of 4.97 K, and it is able to be o perated up to 4.8 K, just below the critical temperature. The detector starts to react to X-ray photons at relatively low bias currents, less than 1% of Ic at T = 1.8 K, and it shows a saturated count rate dependence on bias current at all temperatures, indicating that the optimum internal quantum efficiency can always be reached. Dark counts are negligible up to the highest investigated bias currents (99% of Ic) and operating temperature (4.8 K). The latching effect affects the detector performance at all temperatures due to the fast recovery of the bias current; however, further modifications of the device geometry are expected to reduce the tendency for latching.
151 - H. Kruger , J. Fink , E. Kraft 2008
A hybrid pixel detector based on the concept of simultaneous charge integration and photon counting will be presented. The second generation of a counting and integrating X-ray prototype CMOS chip (CIX) has been operated with different direct convert ing sensor materials (CdZnTe and CdTe) bump bonded to its 8x8 pixel matrix. Photon counting devices give excellent results for low to medium X-ray fluxes but saturate at high rates while charge integration allows the detection of very high fluxes but is limited at low rates by the finite signal to noise ratio. The combination of both signal processing concepts therefore extends the resolvable dynamic range of the X-ray detector. In addition, for a large region of the dynamic range, where counter and integrator operate simultaneously, the mean energy of the detected X-ray spectrum can be calculated. This spectral information can be used to enhance the contrast of the X-ray image. The advantages of the counting and integrating signal processing concept and the performance of the imaging system will be reviewed. The properties of the system with respect to dynamic range and sensor response will be discussed and examples of imaging with additional spectral information will be presented.
For radiography applications using fast neutrons simultaneously with gammas we have developed a detector with 16 stilbene crystals in a 4$times$4 2D array with a 5~mm pitch and a depth of 25~mm. The crystal array is read out by Silicon photomultiplie rs and custom signal processing electronics. The detector prototype was tested using a custom D-D fast neutron generator at the Paul Scherrer Institute. By applying a pulse shape discrimination algorithm the detector is able to detect and distinguish fast neutrons and gammas simultaneously. Various attenuating samples placed between the source and detector with different materials and thicknesses were tested and the measured macroscopic fast neutron cross sections were compared to what was expected. Deviations were studied with the help of detailed Geant4 simulations. The detection efficiency for D-D fast neutrons was measured to be around 10%.
The hyperspectral X-ray imaging has been long sought in various fields from material analysis to medical diagnosis. Here we propose a new semiconductor detector structure to realize energy-resolved imaging at potentially low cost. The working princip le is based on the strong energy-dependent absorption of X-ray in solids. Namely, depending on the energy, X-ray photons experience dramatically different attenuation. An array or matrix of semiconductor cells is to map the X-ray intensity along its trajectory. The X-ray spectrum could be extracted from a Laplace like transform or even a supervised machine learning. We demonstrated an energy-resolved X-ray detection with a regular silicon camera.
212 - P. Abreu , S. Andringa , P. Assis 2017
A new concept for the direct measurement of muons in air showers is presented. The concept is based on resistive plate chambers (RPCs), which can directly measure muons with very good space and time resolution. The muon detector is shielded by placin g it under another detector able to absorb and measure the electromagnetic component of the showers such as a water-Cherenkov detector, commonly used in air shower arrays. The combination of the two detectors in a single, compact detector unit provides a unique measurement that opens rich possibilities in the study of air showers.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا