A hybrid pixel detector based on the concept of simultaneous charge integration and photon counting will be presented. The second generation of a counting and integrating X-ray prototype CMOS chip (CIX) has been operated with different direct converting sensor materials (CdZnTe and CdTe) bump bonded to its 8x8 pixel matrix. Photon counting devices give excellent results for low to medium X-ray fluxes but saturate at high rates while charge integration allows the detection of very high fluxes but is limited at low rates by the finite signal to noise ratio. The combination of both signal processing concepts therefore extends the resolvable dynamic range of the X-ray detector. In addition, for a large region of the dynamic range, where counter and integrator operate simultaneously, the mean energy of the detected X-ray spectrum can be calculated. This spectral information can be used to enhance the contrast of the X-ray image. The advantages of the counting and integrating signal processing concept and the performance of the imaging system will be reviewed. The properties of the system with respect to dynamic range and sensor response will be discussed and examples of imaging with additional spectral information will be presented.
The performance of hybrid GaAs pixel detectors as X-ray imaging sensors were investigated at room temperature. These hybrids consist of 300 mu-m thick GaAs pixel detectors, flip-chip bonded to a CMOS Single Photon Counting Chip (PCC). This chip consi
We present the current status of our project of developing a photon counting detector for medical imaging. An example motivation lays in producing a monitoring and dosimetry device for boron neutron capture therapy, currently not commercially availab
A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present study is op
A prototype Gas Electron Multiplier (GEM) detector is under construction for medical imaging purposes. A single thick GEM of size 10x10 cm^2 is assembled inside a square shaped air-tight box which is made of Perspex glass. In order to ionize gas insi
We describe the concept of a new gamma ray scintronic detector targeting a time resolution of the order of 25 ps FWHM, with millimetric volume reconstruction and high detection efficiency. Its design consists of a monolithic large PbWO4 scintillating