ترغب بنشر مسار تعليمي؟ اضغط هنا

Cryogenic micro-calorimeters for mass spectrometric identification of neutral molecules and molecular fragments

132   0   0.0 ( 0 )
 نشر من قبل Oldrich Novotny
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We have systematically investigated the energy resolution of a magnetic micro-calorimeter (MMC) for atomic and molecular projectiles at impact energies ranging from $Eapprox13$ to 150 keV. For atoms we obtained absolute energy resolutions down to $Delta E approx 120$ eV and relative energy resolutions down to $Delta E/Eapprox10^{-3}$. We also studied in detail the MMC energy-response function to molecular projectiles of up to mass 56 u. We have demonstrated the capability of identifying neutral fragmentation products of these molecules by calorimetric mass spectrometry. We have modeled the MMC energy-response function for molecular projectiles and conclude that backscattering is the dominant source of the energy spread at the impact energies investigated. We have successfully demonstrated the use of a detector absorber coating to suppress such spreads. We briefly outline the use of MMC detectors in experiments on gas-phase collision reactions with neutral products. Our findings are of general interest for mass spectrometric techniques, particularly for those desiring to make neutral-particle mass measurements.



قيم البحث

اقرأ أيضاً

We describe a macroscopic beam splitter for polar neutral molecules. A complex electrode structure is required for the beam splitter which would be very difficult to produce with traditional manufacturing methods. Instead, we make use of a nascent ma nufacturing technique: 3D printing of a plastic piece, followed by electroplating. This fabrication method opens a plethora of avenues for research, since 3D printing imposes practically no limitations on possible shapes, and the plating produces chemically robust, conductive construction elements with an almost free choice of surface material; it has the added advantage of dramatically reduced production cost and time. Our beam splitter is an electrostatic hexapole guide that smoothly transforms into two bent quadrupoles. We demonstrate the correct functioning of this device by separating a supersonic molecular beam of ND3 into two correlated fractions. It is shown that this device can be used to implement experiments with differential detection wherein one of the fractions serves as a probe and the other as a reference. Reverse operation would allow to merging of two beams of neutral polar molecules.
Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $alpha-alpha$ delayed coincidences in $^{232}$Th and $^{238}$U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the $alpha$ decay position.
We have selected and spatially separated the two conformers of 3-aminophenol (C$_6$H$_7$NO) present in a molecular beam. Analogous to the separation of ions based on their mass-to-charge ratios in a quadrupole mass filter, the neutral conformers are separated based on their different mass-to-dipole-moment ratios in an ac electric quadrupole selector. For a given ac frequency, the individual conformers experience different focusing forces, resulting in different transmissions through the selector. These experiments demonstrate that conformer-selected samples of large molecules can be prepared, offering new possibilities for the study of gas-phase biomolecules.
The energy threshold of a cryogenic calorimeter can be lowered by reducing its size. This is of importance since the resulting increase in signal rate enables new approaches in rare-event searches, including the detection of MeV mass dark matter and coherent scattering of reactor or solar neutrinos. A scaling law for energy threshold vs. detector size is given. We analyze the possibility of lowering the threshold of a gram-scale cryogenic calorimeter to the few eV regime. A prototype 0.5 g Al$_2$O$_3$ device achieved an energy threshold of (${19.7pm0.1}$) eV, the lowest value reported for a macroscopic calorimeter.
The BOUND program calculates the bound states of a complex formed from two interacting particles using coupled-channel methods. It is particularly suitable for the bound states of atom-molecule and molecule-molecule Van der Waals complexes and for th e near-threshold bound states that are important in ultracold physics. It uses a basis set for all degrees of freedom except $R$, the separation of the centres of mass of the two particles. The Schrodinger equation is expressed as a set of coupled equations in $R$. Solutions of the coupled equations are propagated outwards from the classically forbidden region at short range and inwards from the classically forbidden region at long range, and matched at a point in the central region. Built-in coupling cases include atom + rigid linear molecule, atom + vibrating diatom, atom + rigid symmetric top, atom + asymmetric or spherical top, rigid diatom + rigid diatom, and rigid diatom + asymmetric top. Both programs provide an interface for plug-in routines to specify coupling cases (Hamiltonians and basis sets) that are not built in. With appropriate plug-in routines, BOUND can take account of the effects of external electric, magnetic and electromagnetic fields, locating bound-state energies at fixed values of the fields. The related program FIELD uses the same plug-in routines and locates values of the fields where bound states exist at a specified energy. As a special case, it can locate values of the external field where bound states cross scattering thresholds and produce zero-energy Feshbach resonances. Plug-in routines are supplied to handle the bound states of a pair of alkali-metal atoms with hyperfine structure in an applied magnetic field.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا