ترغب بنشر مسار تعليمي؟ اضغط هنا

Cross-Calibration of the XMM-Newton EPIC pn & MOS On-Axis Effective Areas Using 2XMM Sources

322   0   0.0 ( 0 )
 نشر من قبل Dr. Andy Read
 تاريخ النشر 2014
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We aim to examine the relative cross-calibration accuracy of the on-axis effective areas of the XMM-Newton EPIC pn and MOS instruments. Spectra from a sample of 46 bright, high-count, non-piled-up isolated on-axis point sources are stacked together, and model residuals are examined to characterize the EPIC MOS-to-pn inter-calibration. The MOS1-to-pn and MOS2-to-pn results are broadly very similar. The cameras show the closest agreement below 1 keV, with MOS excesses over pn of 0-2% (MOS1/pn) and 0-3% (MOS2/pn). Above 3 keV, the MOS/pn ratio is consistent with energy-independent (or only mildly increasing) excesses of 7-8% (MOS1/pn) and 5-8% (MOS2/pn). In addition, between 1-2 keV there is a `silicon bump - an enhancement at a level of 2-4% (MOS1/pn) and 3-5% (MOS2/pn). Tests suggest that the methods employed here are stable and robust. The results presented here provide the most accurate cross-calibration of the effective areas of the XMM-Newton EPIC pn and MOS instruments to date. They suggest areas of further research where causes of the MOS-to-pn differences might be found, and allow the potential for corrections to and possible rectification of the EPIC cameras to be made in the future.



قيم البحث

اقرأ أيضاً

Our understanding of the background of the EPIC/pn camera onboard XMM-Newton is incomplete. This affects the study of extended sources and can influence the predictions of the background of future X-ray missions. We provide new results based on the a nalysis of the largest data set ever used. We focus on the unconcentrated component of the EPIC/pn background - supposedly related to cosmic rays interacting with the telescope. We find that the out-field of view region of the pn detector is actually exposed to the sky. After cleaning from the sky contamination, the unconcentrated background does not show significant spatial variations and its time behaviour is anti-correlated with the solar cycle. We find a very tight, linear correlation between unconcentrated backgrounds detected in the EPIC/pn and MOS2 cameras: this permits the correct evaluation of the pn unconcentrated background of each exposure on the basis of MOS2 data, avoiding the use (as usual) of the contaminated pn regions. We find a tight, linear correlation between the pn unconcentrated background and the proton flux in the 630-970 MeV energy band measured by SOHO/EPHIN. Through this relationship we quantify the contribution of cosmic ray interactions to the pn unconcentrated background and we find a second source which contributes to the pn unconcentrated background for a significant fraction (30%-70%), that does not vary with time and is roughly isotropic. Hard X-ray photons of the CXB satisfy all the known properties of this new component. Our findings provide an important observational confirmation of simulation results on ATHENA.
Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar an alysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-Newton observatory performs observations twice a year of the Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in the fast Timing and Burst modes. We present the results of this monitoring campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38 XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten years of the mission and 13 observations from the five complementary pulsars. All the data were processed with the SAS, the XMM-Newton Scientific Analysis Software, version 9.0. Epoch folding techniques coupled with chi^{2} tests were used to derive relative timing accuracies. The absolute timing accuracy was determined using the Crab data and comparing the time shift between the main X-ray and radio peaks in the phase folded light curves. The relative timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest X-ray pulse peak precedes the corresponding radio peak by 306pm9 mus, which is in agreement with other high energy observatories such as Chandra, INTEGRAL and RXTE. The derived absolute timing accuracy from our analysis is pm48 mus.
159 - Markus Kuster 2002
The EPIC pn CCD camera on board of XMM-Newton is designed to perform high throughput imaging and spectroscopy as well as high resolution timing observations in the energy range of 0.1-15 keV. A temporal resolution of milliseconds or microseconds, dep ending on the instrument mode and detector, is outstanding for CCD based X-ray cameras. In order to calibrate the different observing modes of the EPIC pn CCD, XMM-Newton observations of the pulsars PSR B1509-58, PSR B0540-69 and the Crab were performed during the calibration and performance verification phase. To determine the accuracy of the on board clock against Coordinated Universal Time (UTC), PSR B1509-58 was observed simultaneously with XMM-Newton and RXTE in addition. The paper summarizes the current status of the clock calibration.
84 - P. Ferrando 2002
The XMM-Newton observatory has the largest collecting area flown so far for an X-ray imaging system, resulting in a very high sensitivity over a broad spectral range. In order to exploit fully these performances, a very accurate calibration of the XM M-Newton instruments is required, and has led to an extensive ground and flight calibration program. We report here on the current status of the EPIC/MOS cameras calibrations, highlighting areas for which a reasonably good accuracy has been achieved, and noting points where further work is needed.
67 - J. Nevalainen 2005
We use XMM-Newton blank-sky and closed-cover background data to explore the background subtraction methods for large extended sources filling the EPIC field of view, such as nearby galaxy clusters, for which local background estimation is difficult. We find that to keep the 0.8-7.0 keV band background modeling uncertainty tolerable, one has to use a much more restrictive filter than that commonly applied. In particular, because flares have highly variable spectra, not all of them are identified by filtering the E>10 keV light curve. We tried using the outer part of the EPIC FOV for monitoring the background in a softer band (1-5 keV). We find that one needs to discard the time periods when either the hard-band or the soft-band rate exceeds the nominal value by more than 20% in order to limit the 90% CL background uncertainty to between 5% at E=4-7 keV and 20% at E=0.8-1 keV, for both MOS and PN. This compares to a 10-30% respective PN uncertainty when only the hard-band light curve is used for filtering, and to a 15-45% PN uncertainty when applying the commonly used 2-3 sigma filtering method. We illustrate our method on a nearby cluster A1795. The above background uncertainties convert into the systematic temperature uncertainties between 1% at r=3-4 arcmin and 20--25% (~1 keV for A1795) at r=10-15 arcmin. For comparison, the commonly applied 2-3 sigma clipping of the hard-band light curve misses a significant amount of flares, rendering the temperatures beyond r=10 arcmin unconstrained. Thus, the background uncertainties do not prohibit the EPIC temperature profile analysis of low-brightness regions, like outer regions of galaxy clusters, provided a conservative flare filtering such as the double filtering method with 20% limits is used.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا