ﻻ يوجد ملخص باللغة العربية
Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-Newton observatory performs observations twice a year of the Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in the fast Timing and Burst modes. We present the results of this monitoring campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38 XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten years of the mission and 13 observations from the five complementary pulsars. All the data were processed with the SAS, the XMM-Newton Scientific Analysis Software, version 9.0. Epoch folding techniques coupled with chi^{2} tests were used to derive relative timing accuracies. The absolute timing accuracy was determined using the Crab data and comparing the time shift between the main X-ray and radio peaks in the phase folded light curves. The relative timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest X-ray pulse peak precedes the corresponding radio peak by 306pm9 mus, which is in agreement with other high energy observatories such as Chandra, INTEGRAL and RXTE. The derived absolute timing accuracy from our analysis is pm48 mus.
Our understanding of the background of the EPIC/pn camera onboard XMM-Newton is incomplete. This affects the study of extended sources and can influence the predictions of the background of future X-ray missions. We provide new results based on the a
The EPIC pn CCD camera on board of XMM-Newton is designed to perform high throughput imaging and spectroscopy as well as high resolution timing observations in the energy range of 0.1-15 keV. A temporal resolution of milliseconds or microseconds, dep
We aim to examine the relative cross-calibration accuracy of the on-axis effective areas of the XMM-Newton EPIC pn and MOS instruments. Spectra from a sample of 46 bright, high-count, non-piled-up isolated on-axis point sources are stacked together,
The X-Ray Telescope (XRT) on board Swift was mainly designed to provide detailed position, timing and spectroscopic information on Gamma-Ray Burst (GRB) afterglows. During the mission lifetime the fraction of observing time allocated to other types o
Starting from XMM-Newton EPIC-PN data, we present the X-ray variability characteristics of PKS 2155-304 using a simple analysis of the excess variance, xs, and of the fractional rms variability amplitude, fvar. The scatter in xs and fvar, calculated