ترغب بنشر مسار تعليمي؟ اضغط هنا

On the Calibration of Full-polarization 86GHz Global VLBI Observations

127   0   0.0 ( 0 )
 نشر من قبل Iv\\'an Mart\\'i-Vidal Dr.
 تاريخ النشر 2012
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We report the development of a semi-automatic pipeline for the calibration of 86 GHz full-polarization observations performed with the Global Millimeter-VLBI array (GMVA) and describe the calibration strategy followed in the data reduction. Our calibration pipeline involves non-standard procedures, since VLBI polarimetry at frequencies above 43 GHz is not yet well established. We also present, for the first time, a full-polarization global-VLBI image at 86 GHz (source 3C 345), as an example of the final product of our calibration pipeline, and discuss the effect of instrumental limitations on the fidelity of the polarization images. Our calibration strategy is not exclusive for the GMVA, and could be applied on other VLBI arrays at millimeter wavelengths. The use of this pipeline will allow GMVA observers to get fully-calibrated datasets shortly after the data correlation.



قيم البحث

اقرأ أيضاً

The calibration and analysis of polarization observations in Very Long Baseline Interferometry (VLBI) requires the use of specific algorithms that suffer from several limitations, closely related to assumptions in the data properties that may not hol d in observations taken with new-generation VLBI equipment. Nowadays, the instantaneous bandwidth achievable with VLBI backends can be as high as several GHz, covering several radio bands simultaneously. In addition, the sensitivity of VLBI observations with state-of-the-art equipment may reach dynamic ranges of tens of thousands, both in total intensity and in polarization. In this paper, we discuss the impact of the limitations of common VLBI polarimetry algorithms on narrow-field observations taken with modern VLBI arrays (from the VLBI Global Observing System, VGOS, to the Event Horizon Telescope, EHT) and present new software that overcomes these limitations. In particular, our software is able to perform a simultaneous fit of multiple calibrator sources, include non-linear terms in the model of the instrumental polarization and use a self-calibration approach for the estimate of the polarization leakage in the antenna receivers.
Heterodyne receivers register the sky signal on either a circular polarization basis (where it is split into left-hand and right-hand circular polarization) or a linear polarization basis (where it is split into horizontal and vertical linear polariz ation). We study the problem of interferometric observations performed with telescopes that observe on different polarization bases, hence producing visibilities that we call mixed basis (i.e., linear in one telescope and circular in the other). We present novel algorithms for the proper calibration and treatment of such interferometric observations and test our algorithms with both simulations and real data. The use of our algorithms will be important for the optimum calibration of forthcoming observations with the Atacama Large mm/submm Array (ALMA) in very-long-baseline interferometry (VLBI) mode. Our algorithms will also allow us to optimally calibrate future VLBI observations at very high data rates (i.e., wide bandwidths), where linear-polarization feeds will be preferable at some stations, to overcome the polarimetric limitations due to the use of quarter-wave plates.
We present a detailed description of the special procedures for calibration and quality assurance of Atacama Large Millimeter/submillimeter Array (ALMA) observations in Very Long Baseline Interferometry (VLBI) mode. These procedures are required to t urn the phased ALMA array into a fully calibrated VLBI station. As an illustration of these methodologies, we present full-polarization observations carried out with ALMA as a phased array at 3mm (Band 3) and 1.3mm (Band 6) as part of Cycle-4. These are the first VLBI science observations conducted with ALMA and were obtained during a 2017 VLBI campaign in concert with other telescopes worldwide as part of the Global mm-VLBI Array (GMVA, April 1-3) and the Event Horizon Telescope (EHT, April 5-11) in ALMA Bands 3 and 6, respectively.
With the forthcoming release of high precision polarization measurements, such as from the Planck satellite, the metrology of polarization needs to improve. In particular, it is crucial to take into account full knowledge of the noise properties when estimating polarization fraction and angle, which suffer from well-known biases. While strong simplifying assumptions have usually been made in polarization analysis, we present a method for including the full covariance matrix of the Stokes parameters in estimates for the distributions of the polarization fraction and angle. We thereby quantify the impact of the noise properties on the biases in the observational quantities. We derive analytical expressions for the pdf of these quantities, taking into account the full complexity of the covariance matrix, including the Stokes I intensity components. We perform simulations to explore the impact of the noise properties on the statistical variance and bias of the polarization fraction and angle. We show that for low variations of the effective ellipticity between the Q and U components around the symmetrical case the covariance matrix may be simplified as is usually done, with negligible impact on the bias. For S/N on intensity lower than 10 the uncertainty on the total intensity is shown to drastically increase the uncertainty of the polarization fraction but not the relative bias, while a 10% correlation between the intensity and the polarized components does not significantly affect the bias of the polarization fraction. We compare estimates of the uncertainties affecting polarization measurements, addressing limitations of estimates of the S/N, and we show how to build conservative confidence intervals for polarization fraction and angle simultaneously. This study is the first of a set of papers dedicated to the analysis of polarization measurements.
The Anti Coincidence Shield (ACS) of the INTEGRAL SPI instrument provides an excellent sensitivity for the detection of Gamma Ray Bursts (GRBs) above ~ 75keV, but no directional and energy information is available. We studied the ACS response by usin g GRBs with known localizations and good spectral information derived by other satellites. We derived a count rate to flux conversion factor for different energy ranges and studied its dependence on the GRB direction and spectral hardness. For a typical GRB spectrum, we found that 1 ACS count corresponds on average to ~ 1E-10 erg/cm^2 in the 75keV-1MeV range, for directions orthogonal to the satellite pointing axis. This is broadly consistent with the ACS effective area derived from the Monte Carlo simulations, but there is some indication that the latter slightly overestimates the ACS sensitivity, especially for directions close to the instrument axis.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا