ترغب بنشر مسار تعليمي؟ اضغط هنا

The RHESSI Microflare Height Distribution

190   0   0.0 ( 0 )
 نشر من قبل Steven Christe
 تاريخ النشر 2011
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present the first in-depth statistical survey of flare source heights observed by RHESSI. Flares were found using a flare-finding algorithm designed to search the 6-10 keV count-rate when RHESSIs full sensitivity was available in order to find the smallest events (Christe et al., 2008). Between March 2002 and March 2007, a total of 25,006 events were found. Source locations were determined in the 4-10 keV, 10-15 keV, and 15-30 keV energy ranges for each event. In order to extract the height distribution from the observed projected source positions, a forward-fit model was developed with an assumed source height distribution where height is measured from the photosphere. We find that the best flare height distribution is given by g(h) propto exp(-h/{lambda}) where {lambda} = 6.1pm0.3 Mm is the scale height. A power-law height distribution with a negative power-law index, {gamma} = 3.1 pm 0.1 is also consistent with the data. Interpreted as thermal loop top sources, these heights are compared to loops generated by a potential field model (PFSS). The measured flare heights distribution are found to be much steeper than the potential field loop height distribution which may be a signature of the flare energization process.



قيم البحث

اقرأ أيضاً

We present X-ray imaging and spectral analysis of all microflares the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) observed between March 2002 and March 2007, a total of 25,705 events. These microflares are small flares, from low GOE S C Class to below A Class (background subtracted) and are associated with active regions. They were found by searching the 6-12 keV energy range during periods when the full sensitivity of RHESSIs detectors was available (see paper I). Each microflare is automatically analyzed at the peak time of the 6-12 keV emission: the thermal source size is found by forward-fitting the complex visibilities for 4-8 keV, and the spectral parameters (temperature, emission measure, power-law index) are found by forward fitting a thermal plus non-thermal model. The combination of these parameters allows us to present the first statistical analysis of the thermal and non-thermal energy at the peak times of microflares.
Investigate particle acceleration and heating in a solar microflare. In a microflare with non-thermal emission to remarkably high energies ($>50$ keV), we investigate the hard X-rays with RHESSI imaging and spectroscopy and the resulting thermal emis sion seen in soft X-rays with Hinode/XRT and in EUV with TRACE. The non-thermal footpoints observed with RHESSI spatially and temporally match bright footpoint emission in soft X-rays and EUV. There is the possibility that the non-thermal spectrum extends down to 4 keV. The hard X-ray burst clearly does not follow the expected Neupert effect, with the time integrated hard X-rays not matching the soft X-ray time profile. So although this is a simple microflare with good X-ray observation coverage it does not fit the standard flare model.
298 - G.G. Motorina , E.P. Kontar 2015
To solve a number of problems in solar physics related to mechanisms of energy release in solar corona parameters of hot coronal plasma are required, such as energy distribution, emission measure, differential emission measure, and their evolution wi th time. Of special interest is the distribution of solar plasma by energies, which can evolve from a nearly Maxwellian distribution to a distribution with a more complex structure during a solar flare. The exact form of this distribution for low-energy particles, which receive the bulk of flare energy, is still poorly known; therefore, detailed investigations are required. We present a developed method of simultaneous fitting of data from two spacecrafts Solar Dynamics Observatory/Atmospheric Imaging Assembly (SDO/AIA) and Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI), using a differential emission measure and a thin target model for the August 14, 2010 flare event.
The Spectrometer/Telescope for Imaging X-rays (STIX) is the HXR instrument onboard Solar Orbiter designed to observe solar flares over a broad range of flare sizes, between 4-150 keV. We report the first STIX observations of microflares recorded duri ng the instrument commissioning phase in order to investigate the STIX performance at its detection limit. This first result paper focuses on the temporal and spectral evolution of STIX microflares occuring in the AR12765 in June 2020, and compares the STIX measurements with GOES/XRS, SDO/AIA, and Hinode/XRT. For the observed microflares of the GOES A and B class, the STIX peak time at lowest energies is located in the impulsive phase of the flares, well before the GOES peak time. Such a behavior can either be explained by the higher sensitivity of STIX to higher temperatures compared to GOES, or due to the existence of a nonthermal component reaching down to low energies. The interpretation is inconclusive due to limited counting statistics for all but the largest flare in our sample. For this largest flare, the low-energy peak time is clearly due to thermal emission, and the nonthermal component seen at higher energies occurs even earlier. This suggests that the classic thermal explanation might also be favored for the majority of the smaller flares. In combination with EUV and SXR observations, STIX corroborates earlier findings that an isothermal assumption is of limited validity. Future diagnostic efforts should focus on multi-wavelength studies to derive differential emission measure distributions over a wide range of temperatures to accurately describe the energetics of solar flares. Commissioning observations confirm that STIX is working as designed. As a rule of thumb, STIX detects flares as small as the GOES A class. For flares above the GOES B class, detailed spectral and imaging analyses can be performed.
100 - C. Kuckein 2017
We study small-scale brightenings in Ca II 8542 AA line-core images to determine their nature and effect on localized heating and mass transfer in active regions. High-resolution 2D spectroscopic observations of an active region in the Ca II 8542 AA line were acquired with the GFPI attached to the 1.5-meter GREGOR telescope.