A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was used to evaluate in detail the performance of two Timepix hybrid pixel assemblies; a standard planar 300 micron thick sensor, and 285 micron thick double sided 3D sensor. This paper describes a detailed charge calibration study of the pixel devices, which allows the true charge to be extracted, and reports on measurements of the charge collection characteristics and Landau distributions. The planar sensor achieved a best resolution of 4.0 micron for angled tracks, and resolutions of between 4.4 and 11 micron for perpendicular tracks, depending on the applied bias voltage. The double sided 3D sensor, which has significantly less charge sharing, was found to have an optimal resolution of 9.0 micron for angled tracks, and a resolution of 16.0 micron for perpendicular tracks. Based on these studies it is concluded that the Timepix ASIC shows an excellent performance when used as a device for charged particle tracking.



قيم البحث

اقرأ أيضاً

The Timepix particle tracking telescope has been developed as part of the LHCb VELO Upgrade project, supported by the Medipix Collaboration and the AIDA framework. It is a primary piece of infrastructure for the VELO Upgrade project and is being used for the development of new sensors and front end technologies for several upcoming LHC trackers and vertexing systems. The telescope is designed around the dual capability of the Timepix ASICs to provide information about either the deposited charge or the timing information from tracks traversing the 14 x 14mm matrix of 55 x 55 um pixels. The rate of reconstructed tracks available is optimised by taking advantage of the shutter driven readout architecture of the Timepix chip, operated with existing readout systems. Results of tests conducted in the SPS North Area beam facility at CERN show that the telescope typically provides reconstructed track rates during the beam spills of between 3.5 and 7.5 kHz, depending on beam conditions. The tracks are time stamped with 1 ns resolution with an efficiency of above 98% and provide a pointing resolution at the centre of the telescope of 1.6 um . By dropping the time stamping requirement the rate can be increased to 15 kHz, at the expense of a small increase in background. The telescope infrastructure provides CO2 cooling and a flexible mechanical interface to the device under test, and has been used for a wide range of measurements during the 2011-2012 data taking campaigns.
In the context of the 2013 APS-DPF Snowmass summer study conducted by the U.S. HEP community, this white paper outlines a roadmap for further development of Micro-pattern Gas Detectors for tracking and muon detection in HEP experiments. We briefly di scuss technical requirements and summarize current capabilities of these detectors with a focus of operation in experiments at the energy frontier in the medium-term to long-term future. Some key directions for future R&D on Micro-pattern Gas Detectors in the U.S. are suggested.
We present the first proof-of-concept simulations of detectors using biomaterials to detect particle interactions. The essential idea behind a DNA detector involves the attachment of a forest of precisely-sequenced single or double-stranded nucleic a cids from a thin holding layer made of a high-density material. Incoming particles break a series of strands along a roughly co-linear chain of interaction sites and the severed segments then fall to a collection area. Since the sequences of base pairs in nucleic acid molecules can be precisely amplified and measured using polymerase chain reaction (PCR), the original spatial position of each broken strand inside the detector can be reconstructed with nm precision. Motivated by the potential use as a low-energy directional particle tracker, we perform the first Monte Carlo simulations of particle interactions inside a DNA detector. We compare the track topology as a function of incoming direction, energy, and particle type for a range of ionising particles. While particle identification and energy reconstruction might be challenging without a significant scale-up, the excellent potential angular and spatial resolution ($lesssim 25^circ$ axial resolution for a keV-scale particles and nm-scale track segments) are clear advantages of this concept. We conclude that a DNA detector could be a cost-effective, portable, and powerful new particle detection technology. We outline the outstanding experimental challenges, and suggest directions for future laboratory tests.
358 - Li Zhang 2020
We present the design principle and test results of a data transmitting ASIC, GBS20, for particle physics experiments. The goal of GBS20 will be an ASIC that employs two serializers each from the 10.24 Gbps lpGBT SerDes, sharing the PLL also from lpG BT. A PAM4 encoder plus a VCSEL driver will be implemented in the same die to use the same clock system, eliminating the need of CDRs in the PAM4 encoder. This way the transmitter module, GBT20, developed using the GBS20 ASIC, will have the exact lpGBT data interface and transmission protocol, with an output up to 20.48 Gbps over one fiber. With PAM4 embedded FPGAs at the receiving end, GBT20 will halve the fibers needed in a system and better use the input bandwidth of the FPGA. A prototype, GBS20v0 is fabricated using a commercial 65 nm CMOS technology. This prototype has two serializers and a PAM4 encoder sharing the lpGBT PLL, but no user data input. An internal PRBS generator provides data to the serializers. GBS20v0 is tested barely up to 20.48 Gbps. With lessons learned from this prototype, we are designing the second prototype, GBS20v1, that will have 16 user data input channels each at 1.28 Gbps. We present the design concept of the GBS20 ASIC and the GBT20 module, the preliminary test results, and lessons learned from GBS20v0 and the design of GBS20v1 which will be not only a test chip but also a user chip with 16 input data channels.
The results obtained in laboratory tests, using scintillator bars read by silicon photomultipliers are reported. The present approach is the first step for designing a precision tracking system to be placed inside a free magnetized volume for the cha rge identification of low energy crossing particles. The devised system is demonstrated able to provide a spatial resolution better than 2 mm.