اسأل ChatGPT حول البحث

This contribution investigates a prototype of a TPC readout with a highly pixelated CMOS ASIC, which is an option for charged particles tracking of the ILC. A triple GEM stack was joined with a TimePix and MediPix2 chip (pixel size of 55$times$55 $mu m^2$) and its readout properties were investigated with 5 GeV electrons. The spatial resolution of the cluster center reconstruction was determined as a function of drift distance using different cluster alhoritms and compared with Monte Carlo predictions.



قيم البحث

اقرأ أيضاً

421 - A. Alexandrov 2017
SHiP (Search for Hidden Particles) is a beam dump experiment proposed at the CERN SPS aiming at the observation of long lived particles very weakly coupled with ordinary matter mostly produced in the decay of charmed hadrons. The beam dump facility o f SHiP is also a copious factory of neutrinos of all three kinds and therefore a dedicated neutrino detector is foreseen in the SHiP apparatus. The neutrino detector exploits the Emulsion Cloud Chamber technique with a modular structure, alternating walls of target units and planes of electronic detectors providing the time stamp to the event. GEM detectors are one of the possible choices for this task. This paper reports the results of the first exposure to a muon beam at CERN of a new hybrid chamber, obtained by coupling a GEM chamber and an emulsion detector. Thanks to the micrometric accuracy of the emulsion detector, the position resolution of the GEM chamber as a function of the particle inclination was evaluated in two configurations, with and without the magnetic field
Controlled etching of copper electrodes in Gas Electron Multiplier foils allows a reduction of the material budget by more than a factor of two for a triple-GEM detector. Detectors making use of thinned foils provide performances similar to those obt ained with standard devices: a gain above 10^4 for a double-GEM, with energy resolution of 27 % fwhm for 5.9 keV X-rays.
At NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are performed. The method and test results are presented.
336 - Y.L. Zhang , H.R. Qi , Z.W. Wen 2017
A triple-GEM detector with two-dimensional readout is developed. The detector provides high position resolution for powder diffraction experiments at synchrotron radiation. Spatial resolution of the detector is measured in the lab using a 55Fe X-ray source. A resolution of about 110 um FWHM is achieved. The energy resolution is better than 27% for 5.9 keV X-rays. The detectors validity under illumination of photons in particular energy range is verified using a Cu X-ray tube. Imaging of the head of a wire stripper with X-ray tube demonstrates its imaging ability. A diffraction imaging experiment using the sample of powder SiO2 is successfully carried out at 1W2B laboratory of Beijing Synchrotron Radiation Facility (BSRF). Different diffraction rings are clearly seen under various X-ray energies.