Do you want to publish a course? Click here

NICER Detects a Soft X-ray Kilohertz Quasi-periodic Oscillation in 4U 0614+09

70   0   0.0 ( 0 )
 Added by Peter Bult
 Publication date 2018
  fields Physics
and research's language is English




Ask ChatGPT about the research

We report on the detection of a kilohertz quasi-periodic oscillation (QPO) with the Neutron Star Interior Composition Explorer (NICER). Analyzing approximately 165 ks of NICER exposure on the X-ray burster 4U 0614+09, we detect multiple instances of a single-peak upper kHz QPO, with centroid frequencies that range from 400 Hz to 750 Hz. We resolve the kHz QPO as a function of energy, and measure, for the first time, the QPO amplitude below 2 keV. We find the fractional amplitude at 1 keV is on the order of 2% rms, and discuss the implications for the QPO emission process in the context of Comptonization models.

rate research

Read More

113 - M. Linares 2012
Thermonuclear bursts from slowly accreting neutron stars (NSs) have proven difficult to detect, yet they are potential probes of the thermal properties of the neutron star interior. During the first year of a systematic all-sky search for X-ray bursts using the Gamma-ray Burst Monitor (GBM) aboard the Fermi Gamma-ray Space Telescope we have detected 15 thermonuclear bursts from the NS low-mass X-ray binary 4U 0614+09, when it was accreting at nearly 1% of the Eddington limit. We measured an average burst recurrence time of 12+/-3 d (68% confidence interval) between March 2010 and March 2011, classified all bursts as normal duration bursts and placed a lower limit on the recurrence time of long/intermediate bursts of 62 d (95% confidence level). We discuss how observations of thermonuclear bursts in the hard X-ray band compare to pointed soft X-ray observations, and quantify such bandpass effects on measurements of burst radiated energy and duration. We put our results for 4U 0614+09 in the context of other bursters and briefly discuss the constraints on ignition models. Interestingly, we find that the burst energies in 4U 0614+09 are on average between those of normal duration bursts and those measured in long/intermediate bursts. Such a continuous distribution in burst energy provides a new observational link between normal and long/intermediate bursts. We suggest that the apparent bimodal distribution that defined normal and long/intermediate duration bursts during the last decade could be due to an observational bias towards detecting only the longest and most energetic bursts from slowly accreting NSs.
(abridged) We studied the energy and frequency dependence of the Fourier time lags and intrinsic coherence of the kHz QPOs in the NS LMXBs 4U 1608-52 and 4U 1636-53 using RXTE data. In both sources we confirmed energy-dependent soft lags of 10-100 mu s for the lower kHz QPO. We also found that the time lags of the upper kHz QPO are independent of energy and inconsistent with the soft lags of the lower kHz QPO. The intrinsic coherence of the lower kHz QPO remains constant at 0.6 from 5 to 12 keV, and then drops to zero, while for the upper kHz QPO the intrinsic coherence is consistent with zero across the full energy range. The intrinsic coherence of the upper kHz QPO is consistent with zero over the full frequency range of the QPO, except in 4U 1636-53 at ~780 Hz where it increases to 0.13. In 4U 1636-53, for the lower kHz QPO the 4-12 keV photons lag the 12-20 keV ones by 25 mu s in the QPO frequency range 500-850 Hz, with the lags decreasing to 15 mu s at higher frequencies. In 4U 1608-52 the soft lags of the lower kHz QPO remain constant at 40 mu s. In 4U 1636-53, for the upper kHz QPO the 12-20 keV photons lag the 4-12 keV ones by 11 +/- 3 mu s, independent of QPO frequency; we found consistent results for the time lags of the upper kHz QPO in 4U 1608-52. The intrinsic coherence of the lower kHz QPO increases from ~0-0.4 at 600 Hz to 1 and 0.6 at 800 Hz in 4U 1636-53 and 4U 1608-52, respectively. In 4U 1636-53 it decreases to 0.5 at 920 Hz, while in 4U 1608-52 we do not have data above 800 Hz. We discuss our results in the context of scenarios in which the soft lags are either due to reflection off the accretion disc or up-/down-scattering in a hot medium close to the neutron star. We finally explore the connection between, on one hand the time lags and the intrinsic coherence of the kHz QPOs, and on the other the QPOs amplitude and quality factor in these two sources.
A kilohertz quasi-periodic oscillation (kHz QPO) is an observationally robust high-frequency timing feature detected from neutron star low-mass X-ray binaries (LMXBs). This feature can be very useful to probe the superdense core matter of neutron stars, and the strong gravity regime. However, although many models exist in the literature, the physical origin of kHz QPO is not known, and hence this feature cannot be used as a tool yet. The energy dependence of kHz QPO fractional rms amplitude is an important piece of the jigsaw puzzle to understand the physical origin of this timing feature. It is known that the fractional rms amplitude increases with energy at lower energies. At higher energies, the amplitude is usually believed to saturate, although this is not established. We combine tens of lower kHz QPOs from a neutron star LMXB 4U 1728-34 in order to improve the signal-to-noise-ratio. Consequently, we, for the first time to the best of our knowledge, find a significant and systematic decrease of the fractional rms amplitude with energy at higher photon energies. Assuming an energy spectrum model, blackbody+powerlaw, we explore if the sinusoidal variation of a single spectral parameter can reproduce the above mentioned fractional rms amplitude behavior. Our analysis suggests that the oscillation of any single blackbody parameter is favored over the oscillation of any single powerlaw parameter, in order to explain the measured amplitude behavior. We also find that the quality factor of a lower kHz QPO does not plausibly depend on photon energy.
We present the discovery of a low-frequency $approx 5.7$ Hz quasi-periodic oscillation (QPO) feature in observations of the black hole X-ray binary MAXI J1535-571 in its soft-intermediate state, obtained in September-October 2017 by the Neutron Star Interior Composition Explorer (NICER). The feature is relatively broad (compared to other low-frequency QPOs; quality factor $Qapprox 2$) and weak (1.9% rms in 3-10 keV), and is accompanied by a weak harmonic and low-amplitude broadband noise. These characteristics identify it as a weak Type A/B QPO, similar to ones previously identified in the soft-intermediate state of the transient black hole X-ray binary XTE J1550-564. The lag-energy spectrum of the QPO shows increasing soft lags towards lower energies, approaching 50 ms at 1 keV (with respect to a 3-10 keV continuum). This large phase shift has similar amplitude but opposite sign to that seen in Rossi X-ray Timing Explorer data for a Type B QPO from the transient black hole X-ray binary GX 339-4. Previous phase-resolved spectroscopy analysis of the Type B QPO in GX 339-4 pointed towards a precessing jet-like corona illuminating the accretion disk as the origin of the QPO signal. We suggest that this QPO in MAXI J1535-571 may have the same origin, with the different lag sign depending on the scale height of the emitting region and the observer inclination angle.
129 - Andrea Sanna 2012
We analysed all archival RXTE observations of the neutron-star low-mass X-ray binary 4U 1636-53 up to May 2010. In 528 out of 1280 observations we detected kilohertz quasi-periodic oscillations (kHz QPOs), with ~ 65% of these detections corresponding to the so-called lower kHz QPO. Using this QPO we measured, for the first time, the rate at which the QPO frequency changes as a function of QPO frequency. For this we used the spread of the QPO frequency over groups of 10 consecutive measurements, sampling timescales between 320 and 1600 s, and the time derivative of the QPO frequency over timescales of 32 to 160 s. We found that: (i) Both the QPO-frequency spread and the QPO time derivative decrease by a factor ~ 3 as the QPO frequency increases. (ii) The average value of the QPO time derivative decreases by a factor of ~ 2 as the timescale over which the derivative is measured increases from less than 64 s to 160 s. (iii) The relation between the absolute value of the QPO time derivative and the QPO frequency is consistent with being the same both for the positive and negative QPO-frequency derivative. We show that, if either the lower or the upper kHz QPO reflects the Keplerian frequency at the inner edge of the accretion disc, these results support a scenario in which the inner part of the accretion disc is truncated at a radius that is set by the combined effect of viscosity and radiation drag.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا