Do you want to publish a course? Click here

Displacement power spectrum measurement of a macroscopic optomechanical system at thermal equilibrium

35   0   0.0 ( 0 )
 Publication date 2006
  fields Physics
and research's language is English




Ask ChatGPT about the research

The mirror relative motion of a suspended Fabry-Perot cavity is studied in the frequency range 3-10 Hz. The experimental measurements presented in this paper, have been performed at the Low Frequency Facility, a high finesse optical cavity 1 cm long suspended to a mechanical seismic isolation system identical to that one used in the VIRGO experiment. The measured relative displacement power spectrum is compatible with a system at thermal equilibrium within its environmental. In the frequency region above 3 Hz, where seismic noise contamination is negligible, the measurement distribution is stationary and Gaussian, as expected for a system at thermal equilibrium. Through a simple mechanical model it is shown that: applying the fluctuation dissipation theorem the measured power spectrum is reproduced below 90 Hz and noise induced by external sources are below the measurement.



rate research

Read More

An exact and analytical solution of four dimensional vacuum General Relativity representing a system of two static black holes at equilibrium is presented. The metric is completely regular outside the event horizons, both from curvature and conical singularities. The balance between the two Schwarzschild sources is granted by an external gravitational field, without the need of extra matter fields besides gravity, nor strings or struts. The geometry of the solution is analysed. The Smarr law, the first and the second law of black hole thermodynamics are discussed.
This paper shows a novel method to precisely measure the laser power using an optomechanical system. By measuring a mirror displacement caused by the reflection of an amplitude modulated laser beam, the number of photons in the incident continuous-wave laser can be precisely measured. We have demonstrated this principle by means of a prototype experiment uses a suspended 25 mg mirror as an mechanical oscillator coupled with the radiation pressure and a Michelson interferometer as the displacement sensor. A measurement of the laser power with an uncertainty of less than one percent (1 sigma) is achievable.
We report on experimental observation of radiation-pressure induced effects in a high-power optical cavity. These effects play an important role in next generation gravitational wave (GW) detectors, as well as in quantum non-demolition (QND) interferometers. We measure the properties of an optical spring, created by coupling of an intense laser field to the pendulum mode of a suspended mirror; and also the parametric instability (PI) that arises from the nonlinear coupling between acoustic modes of the cavity mirrors and the cavity optical mode. Specifically, we measure an optical rigidity of $K = 3 times 10^4$ N/m, and PI value $R = 3$.
78 - Ru Ling , Hao Xu , Yen Chin Ong 2021
It is commonly known in the literature that large black holes in anti-de Sitter spacetimes (with reflective boundary condition) are in thermal equilibrium with their Hawking radiation. Focusing on black holes with event horizon of toral topology, we study a simple model to understand explicitly how this thermal equilibrium is reached under Hawking evaporation. It is shown that it is possible for a large toral black hole to evolve into a small (but stable) one.
We achieved for the first time a direct measurement of the thermal fluctuation of a pendulum in an off-resonant region using a laser interferometric gravitational wave detector. These measurements have been well identified for over one decade by an agreement with a theoretical prediction, which was derived by a fluctuation-dissipation theorem. Thermal fluctuation is dominated by the contribution of resistances in coil-magnet actuator circuits. When we tuned these resistances, the noise spectrum also changed according to a theoretical prediction. The measured thermal noise level corresponds to a high quality factor on the order of 10^5 of the pendulum.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا