Performance of the ReD TPC, a novel double-phase LAr detector with Silicon Photomultiplier Readout

152   0   0.0 ( 0 )
 Added by Luciano Pandola
 Publication date 2021
  fields Physics
and research's language is English




Ask ChatGPT about the research

A double-phase argon Time Projection Chamber (TPC), with an active mass of 185 g, has been designed and constructed for the Recoil Directionality (ReD) experiment. The aim of the ReD project is to investigate the directional sensitivity of argon-based TPCs via columnar recombination to nuclear recoils in the energy range of interest (20-200 keV$_{nr}$) for direct dark matter searches. The key novel feature of the ReD TPC is a readout system based on cryogenic Silicon Photomultipliers, which are employed and operated continuously for the first time in an argon TPC. Over the course of six months, the ReD TPC was commissioned and characterised under various operating conditions using $gamma$-ray and neutron sources, demonstrating remarkable stability of the optical sensors and reproducibility of the results. The scintillation gain and ionisation amplification of the TPC were measured to be $g_1 = (0.194 pm 0.013)$ PE/photon and $g_2 = (20.0 pm 0.9)$ PE/electron, respectively. The ratio of the ionisation to scintillation signals (S2/S1), instrumental for the positive identification of a candidate directional signal induced by WIMPs, has been investigated for both nuclear and electron recoils. At a drift field of 183 V/cm, an S2/S1 dispersion of 12% was measured for nuclear recoils of approximately 60-90 keV$_{nr}$, as compared to 18% for electron recoils depositing 60 keV of energy. The detector performance reported here meets the requirements needed to achieve the principal scientific goals of the ReD experiment in the search for a directional effect due to columnar recombination. A phenomenological parameterisation of the recombination probability in LAr is presented and employed for modeling the dependence of scintillation quenching and charge yield on the drift field for electron recoils between 50-500 keV and fields up to 1000 V/cm.



rate research

Read More

In this paper we describe the design, construction, and operation of a first large area double-phase liquid argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). The detector has a maximum drift length of 60 cm and the readout consists of a $40times 76$ cm$^2$ LEM and 2D projective anode to multiply and collect drifting charges. Scintillation light is detected by means of cryogenic PMTs positioned below the cathode. To record both charge and light signals, we have developed a compact acquisition system, which is scalable up to ton-scale detectors with thousands of charge readout channels. The acquisition system, as well as the design and the performance of custom-made charge sensitive preamplifiers, are described. The complete experimental setup has been operated for a first time during a period of four weeks at CERN in the cryostat of the ArDM experiment, which was equipped with liquid and gas argon purification systems. The detector, exposed to cosmic rays, recorded events with a single-channel signal-to-noise ratio in excess of 30 for minimum ionising particles. Cosmic muon tracks and their $delta$-rays were used to assess the performance of the detector, and to estimate the liquid argon purity and the gain at different amplification fields.
ARGONTUBE is a liquid argon time projection chamber (TPC) with an electron drift length of up to 5 m equipped with cryogenic charge-sensitive preamplifiers. In this work, we present results on its performance including a comparison of the new cryogenic charge-sensitive preamplifiers with the previously used room-temperature-operated charge preamplifiers.
The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two channels for fibers at the Fermilab NICADD facility. Each fiber end is read out by a 2*2 mm^2 silicon photomultiplier. The signals were amplified and digitized by a custom-made front-end electronics board. Combinations of 5*2 cm^2 and 6*2 cm^2 extrusion profiles with 1.4 and 1.8 mm diameter fibers were tested. The design is intended for the cosmic-ray veto detector for the Mu2e experiment at Fermilab. The light yield as a function of the transverse and longitudinal position of the beam will be given.
134 - T. Lux 2018
For the future neutrino oscillation experiment DUNE, liquid argon time projections chambers with a fiducial mass of 10 kton each are foreseen. The dual phase concept is one of the two implementations considered, wherein electrons produced by ionization in the liquid are extracted to a gaseous region above the liquid where they are amplified. For the amplification, large electron multipliers will be used. The technology was tested in various prototypes, most recently with a 3 x 1 x 1 m$^3$ large setup. An even larger prototype of 6 x 6 x 6 m$^3$ is currently being constructed and will start operation in 2019. An intensive R&D program was carried out with the focus on achieving an effective gain of at least 20. In the simulation study here presented for the first time not only the electron signal is considered but also the ion backflow and the expected production of secondary scintillation light is studied, because the latter might limit the capability of the detector to trigger on low energetic no-beam physics. It is found that the ion backflow and the light yield can be expected to be very large. The results for the effective gain show a discrepancy with experimental data, both in size and shape of the gain curve. Based on literature studies, it is argued that photon feedback contributes to the gain in detectors filled with pure noble gases, especially in the case of pure argon.
667 - H.Chen , J.Evans , J.Fried 2018
Short Baseline Near Detector (SBND), which is a 260-ton LAr TPC as near detector in Short Baseline Neutrino (SBN) program, consists of 11,264 TPC readout channels. As an enabling technology for noble liquid detectors in neutrino experiments, cold electronics developed for extremely low temperature (77K - 89K) decouples the electrode and cryostat design from the readout design. With front-end electronics integrated with detector electrodes, the noise is independent of the fiducial volume and about half as with electronics at room temperature. Digitization and signal multiplexing to high speed serial links inside cryostat result in large reduction in the quantity of cables (less outgassing) and the number of feed-throughs, therefore minimize the penetration and simplify the cryostat design. Being considered as an option for the TPC readout, several Commercial-Off-The-Shelf (COTS) ADC chips have been identified as good candidates for operation in cryogenic temperature after initial screening test. Because Hot Carrier Effects (HCE) degrades CMOS device lifetime, one candidate, ADI AD7274 fabricated in TSMC 350nm CMOS technology, of which lifetime at cryogenic temperature is studied. The lifetime study includes two phases, the exploratory phase and the validation phase. This paper describes the test method, test setup, observations in the exploratory phase and the validation phase. Based on the current test data, the preliminary lifetime projection of AD7274 is about 6.1 $times$ $10^6$ years at 2.5V operation at cryogenic temperature, which means the HCE degradation is negligible during the SBND service life.