Characterization of high aspect ratio TiAu TES X-ray microcalorimeters array using the X-IFU Frequency Domain Multiplexing readout

84   0   0.0 ( 0 )
 Added by Emanuele Taralli
 Publication date 2021
  fields Physics
and research's language is English




Ask ChatGPT about the research

We are developing X-ray microcalorimeters as a backup option for the baseline detectors in the X-IFU instrument on board the ATHENA space mission led by ESA and to be launched in the early 2030s.5$times$5 mixed arrays with TiAu transition-edge sensor (TES), which have different high aspect ratios and thus high resistances, have been designed and fabricated to meet the energy resolution requirement of the X-IFU instrument. Such arrays can also be used to optimise the performance of the Frequency Domain Multiplexing (FDM) readout and lead to the final steps for the fabrication of a large detector array. In this work we present the experimental results from tens of the devices with an aspect ratio (length-to-width) ranging from 1-to-1 up to 6-to-1, measured in a single-pixel mode with a FDM readout system developed at SRON/VTT. We observed a nominal energy resolution of about 2.5 eV at 5.9 keV at bias frequencies ranging from 1 to 5 MHz. These detectors are proving to be the best TES microcalorimeters ever reported in Europe, being able to meet not only the requirements of the X-IFU instrument, but also those of other future challenging X-ray space missions, fundamental physics experiments, plasma characterization and material analysis.



rate research

Read More

The Transition-Edge Sensor (TES) is an extremely sensitive device which is used to measure the energy of individual X-ray photons. For astronomical spectrometry applications, SRON develops a Frequency Domain Multiplexing (FDM) read-out system for kilopixel arrays of such TESs. Each TES is voltage biased at a specific frequency in the range 1 to 5 MHz. Isolation between the individual pixels is obtained through very narrow-band (high-Q) lithographic LC resonators. To prevent energy resolution degradation due to intermodulation line noise, the bias frequencies are distributed on a regular grid. The requirements on the accuracy of the LC resonance frequency are very high. The deviation of the resonance frequencies due to production tolerances is significant with respect to the bandwidth, and a controller is necessary to compensate for the LC series impedance. We present two such controllers: a simple orthogonal proportional-integrating (PI) controller and a more complex impedance estimator. Both controllers operate in baseband and try to make the TES current in-phase with the bias voltage, effectively operating as phase-locked loops (PLL). They allow off-LC-resonance operation of the TES pixels, while preserving TES thermal response and energy resolution. Extensive experimental results -- published in a companion paper recently -- with the proposed methods, show that these controllers allow the preservation of single pixel energy resolution in multiplexed operation.
We demonstrate the code-division multiplexed (CDM) readout of eight transition-edge sensor microcalorimeters. The energy resolution is 3.0 eV (full width at half-maximum) or better at 5.9 keV, with a best resolution of 2.3 eV and a mean of 2.6 eV over the seven modulated detectors. The flux-summing CDM system is described and compared with similar time-division multiplexed (TDM) readout. We show that the sqrt(Npixels) multiplexing disadvantage associated with TDM is not present in CDM. This demonstration establishes CDM as both a simple route to higher performance in existing TDM microcalorimetric experiments and a long-term approach to reaching higher multiplexing factors.
In the frequency-domain multiplexing (FDM) scheme, transition-edge sensors (TES) are individually coupled to superconducting LC filters and AC biased at MHz frequencies through a common readout line. To make efficient use of the available readout bandwidth and to minimize the effect of non-linearities, the LC resonators are usually designed to be on a regular grid. The lithographic processes however pose a limit on the accuracy of the effective filter resonance frequencies. Off-resonance bias carriers could be used to suppress the impact of intermodulation distortions, which nonetheless would significantly affect the effective bias circuit and the detector spectral performance. In this paper we present a frequency shift algorithm (FSA) to allow off-resonance readout of TESs while preserving the on-resonance bias circuit and spectral performance, demonstrating its application to the FDM readout of a X-ray TES microcalorimeter array. We discuss the benefits in terms of mitigation of the impact of intermodulation distortions at the cost of increased bias voltage and the scalability of the algorithm to multi-pixel FDM readout. We show that with FSA, in multi-pixel and frequencies shifted on-grid, the line noises due to intermodulation distortion are placed away from the sensitive region in the TES response and the X-ray performance is consistent with the single-pixel, on-resonance level.
Transition-edge sensor X-ray microcalorimeters are usually calibrated empirically, as the most widely-used calibration metric, optimal filtered pulse height (OFPH), in general has an unknown dependance on photon energy, $E_{gamma}$. Because the calibration function can only be measured at specific points where photons of a known energy can be produced, this unknown dependence of OFPH on $E_{gamma}$ leads to calibration errors and the need for time-intensive calibration measurements and analysis. A calibration metric that is nearly linear as a function of $E_{gamma}$ could help alleviate these problems. In this work, we assess the linearity of a physically motivated calibration metric, $E_{Joule}$. We measure calibration pulses in the range 4.5 keV$<$$E_{gamma}$$<$9.6 keV with detectors optimized for 6 keV photons to compare the linearity properties of $E_{Joule}$ to OFPH. In these test data sets, we find that $E_{Joule}$ fits a linear function an order of magnitude better than OFPH. Furthermore, calibration functions using $E_{J}$, an optimized version of $E_{Joule}$, are linear within the 2-3 eV noise of the data.
225 - T. Lanting , M. Dobbs , H. Spieler 2009
We have designed and demonstrated a Superconducting Quantum Interference Device (SQUID) array linearized with cryogenic feedback. To achieve the necessary loop gain a 300 element series array SQUID is constructed from three monolithic 100-element series arrays. A feedback resistor completes the loop from the SQUID output to the input coil. The short feedback path of this Linearized SQUID Array (LISA) allows for a substantially larger flux-locked loop bandwidth as compared to a SQUID flux-locked loop that includes a room temperature amplifier. The bandwidth, linearity, noise performance, and dynamic range of the LISA are sufficient for its use in our target application: the multiplexed readout of transition-edge sensor bolometers.