Do you want to publish a course? Click here

Investigation of potential ultra-low $Q$-value $beta$-decay candidates $^{89}$Sr and $^{139}$Ba using Penning trap mass spectrometry

99   0   0.0 ( 0 )
 Added by Rachel Sandler
 Publication date 2019
  fields
and research's language is English




Ask ChatGPT about the research

Background: Ultra-low $Q$-value $beta$-decays are interesting processes to study with potential applications to nuclear $beta$-decay theory and neutrino physics. While a number of potential ultra-low $Q$-value $beta$-decay candidates exist, improved mass measurements are necessary to determine which are energetically allowed. Method: Penning trap mass spectrometry was used to determine the atomic mass of $^{89}$Y and $^{139}$La, from which $beta$-decay $Q$-values for $^{89}$Sr and $^{139}$Ba were obtained to determine if there could be an ultra-low $Q$-value decay branch in the $beta$-decay of $^{89}$Sr $rightarrow$ $^{89}$Y or $^{139}$Ba $rightarrow$ $^{139}$La. Results: The $^{89}$Sr $rightarrow$ $^{89}$Y and $^{139}$Ba $rightarrow$ $^{139}$La $beta$-decay $Q$-values were measured to be $Q_{rm{Sr}}$ = 1502.20(0.35) keV and $Q_{rm{Ba}}$ = 2308.37(68) keV. These were compared to energies of excited states in $^{89}$Y at 1507.4(1) keV, and in $^{139}$La at 2310(19) keV and 2313(1) keV to determine $Q$-values of -5.20(37) keV for the potential ultra-low $beta$-decay branch of $^{89}$Sr and -1.6(19.0) keV and -4.6(1.2) keV for those of $^{139}$Ba. Conclusion: The potential ultra-low $Q$-value decay branch of $^{89}$Sr to the $^{89}$Y (3/2$^-$, 1507.4 keV) state is energetically forbidden and has been ruled out. The potential ultra-low $Q$-value decay branch of $^{139}$Ba to the 2313 keV state in $^{139}$La with unknown J$^{pi}$ has also been ruled out at the 4$sigma$ level, while more precise energy level data is needed for the $^{139}$La (1/2$^+$, 2310 keV) state to determine if an ultra-low $Q$-value $beta$-decay branch to this state is energetically allowed.



rate research

Read More

Background: The understanding and description of forbidden decays provides interesting challenges for nuclear theory. These calculations could help to test underlying nuclear models and interpret experimental data. Purpose: Compare a direct measurement of the $^{138}$La $beta$-decay $Q$ value with the $beta$-decay spectrum end-point energy measured by Quarati et al. using LaBr$_3$ detectors [Appl. Radiat. Isot. 108, 30 (2016)]. Use new precise measurements of the $^{138}$La $beta$-decay and electron capture (EC) $Q$ values to improve theoretical calculations of the $beta$-decay spectrum and EC probabilities. Method: High-precision Penning trap mass spectrometry was used to measure cyclotron frequency ratios of $^{138}$La, $^{138}$Ce and $^{138}$Ba ions from which $beta$-decay and EC $Q$ values for $^{138}$La were obtained. Results: The $^{138}$La $beta$-decay and EC $Q$ values were measured to be $Q$ = 1052.42(41) keV and $Q_{EC}$ = 1748.41(34) keV, improving the precision compared to the values obtained in the most recent atomic mass evaluation [Wang, et al., Chin. Phys. C 41, 030003 (2017)] by an order of magnitude. These results are used for improved calculations of the $^{138}$La $beta$-decay shape factor and EC probabilities. New determinations for the $^{138}$Ce 2EC $Q$ value and the atomic masses of $^{138}$La, $^{138}$Ce, and $^{138}$Ba are also reported. Conclusion: The $^{138}$La $beta$-decay $Q$ value measured by Quarati et al. is in excellent agreement with our new result, which is an order of magnitude more precise. Uncertainties in the shape factor calculations for $^{138}$La beta-decay using our new $Q$ value are reduced by an order of magnitude. Uncertainties in the EC probability ratios are also reduced and show improved agreement with experimental data.
186 - G. Eitel , M. Block , A. Czasch 2009
A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from a Penning trap are described. This will allow for a precise monitoring of the state of ion motion in the trap.
Penning trap measurements using mixed beams of 100Mo - 100Ru and 76Ge - 76Se have been utilized to determine the double-beta decay Q-values of 100Mo and 76Ge with uncertainties less than 200 eV. The value for 76Ge, 2039.04(16) keV is in agreement with the published SMILETRAP value. The new value for 100Mo, 3034.40(17) keV is 30 times more precise than the previous literature value, sufficient for the ongoing neutrinoless double-beta decay searches in 100Mo. Moreover, the precise Q-value is used to calculate the phase-space integrals and the experimental nuclear matrix element of double-beta decay.
93 - P. Belli 2011
A search for double beta processes in 190Pt and 198Pt was realized with the help of ultra-low background HP Ge 468 cm^3 gamma spectrometer in the underground Gran Sasso National Laboratories of the INFN (Italy). After 1815 h of data taking with 42.5 g platinum sample, T_{1/2} limits on 2beta processes in 190Pt (epsilonbeta^+ and 2epsilon) have been established on the level of 10^{14}-10^{16} yr, 3 to 4 orders of magnitude higher than those known previously. In particular, a possible resonant double electron capture in 190Pt was restricted on the level of 2.9 times 10^{16} yr at 90% C.L. In addition, T_{1/2} limit on 2 beta^- decay of 198Pt (2 u+0 u) to the 2^+_1 excited level of 198Hg has been set at the first time: T_{1/2}>3.5 times 10^{18} yr. The radiopurity level of the used platinum sample is reported.
74 - T. Eronen 2005
Masses of the radioactive isotopes 62Ga, 62Zn and 62Cu have been measured at the JYFLTRAP facility with a relative precision of better than 18 ppb. A Q_EC value of (9181.07 +- 0.54) keV for the superallowed decay of 62Ga is obtained from the measured cyclotron frequency ratios of 62Ga-62Zn, 62Ga-62Ni and 62Zn-62Ni ions. The resulting Ft-value supports the validity of the conserved vector current hypothesis (CVC). The mass excess values measured were (-51986.5 +-1.0) keV for 62Ga, (-61167.9 +- 0.9) keV for 62Zn and (-62787.2 +- 0.9) keV for 62Cu.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا