Do you want to publish a course? Click here

Noise suppression in inverse weak value based phase detection

366   0   0.0 ( 0 )
 Added by Kevin Lyons
 Publication date 2017
  fields Physics
and research's language is English




Ask ChatGPT about the research

We examine the effect of different sources of technical noise on inverse weak value-based precision phase measurements. We find that this type of measurement is similarly robust to technical noise as related experiments in the weak value regime. In particular, the measurements considered here are robust to additive Gaussian white noise and angular jitter noise commonly encountered in optical experiments. Additionally, we show the same techniques used for precision phase measurement can be used with the same technical advantages for optical frequency measurements.



rate research

Read More

We improve the precision of the interferometric weak-value-based beam deflection measurement by introducing a power recycling mirror, creating a resonant cavity. This results in emph{all} the light exiting to the detector with a large deflection, thus eliminating the inefficiency of the rare postselection. The signal-to-noise ratio of the deflection is itself magnified by the weak value. We discuss ways to realize this proposal, using a transverse beam filter and different cavity designs.
We present an interferometric technique for measuring ultra-small tilts. The information of a tilt in one of the mirrors of a modified Sagnac interferometer is carried by the phase difference between the counter propagating laser beams. Using a small misalignment of the interferometer, orthogonal to the plane of the tilt, a bimodal (or two-fringe) pattern is induced in the beams transverse power distribution. By tracking the mean of such a distribution, using a split detector, a sensitive measurement of the phase is performed. With 1.2 mW of continuous-wave laser power, the technique has a shot noise limited sensitivity of 56 frad/$sqrt{mbox{Hz}}$, and a measured noise floor of 200 frad/$sqrt{mbox{Hz}}$ for tilt frequencies above 2 Hz. A tilt of 200 frad corresponds to a differential displacement of 4.0 fm in our setup. The novelty of the protocol relies on signal amplification due to the misalignment, and on good performance at low frequencies. A noise floor of about 70 prad/$sqrt{mbox{Hz}}$ is observed between 2 and 100 mHz.
In a quantum-noise limited system, weak-value amplification using post-selection normally does not produce more sensitive measurements than standard methods for ideal detectors: the increased weak value is compensated by the reduced power due to the small post-selection probability. Here we experimentally demonstrate recycled weak-value measurements using a pulsed light source and optical switch to enable nearly deterministic weak-value amplification of a mirror tilt. Using photon counting detectors, we demonstrate a signal improvement by a factor of $4.4 pm 0.2$ and a signal-to-noise ratio improvement of $2.10 pm 0.06$, compared to a single-pass weak-value experiment, and also compared to a conventional direct measurement of the tilt. The signal-to-noise ratio improvement could reach around 6 for the parameters of this experiment, assuming lower loss elements.
Recent advances in micro- and nanofabrication techniques have led to corresponding improvement in the performance of optomechanical systems, which provide a promising avenue towards quantum-limited metrology and the study of quantum behavior in macroscopic mechanical objects. One major impediment to reaching the quantum regime is thermal excitation, which can be overcome for sufficiently high mechanical quality factor Q. Here, we propose a method for increasing the effective Q of a mechanical resonator by stiffening it via the optical spring effect exhibited by linear optomechanical systems, and show how the associated quantum radiation pressure noise can be evaded by sensing and feedback control. In a parameter regime that is attainable with current technology, this method allows for realistic quantum cavity optomechanics in a frequency band well below that which has been realized thus far.
121 - Mu Yang , Qiang Li , Zheng-Hao Liu 2019
Weak measurement has been shown to play important roles in the investigation of both fundamental and practical problems. Anomalous weak values are generally believed to be observed only when post-selection is performed, i.e, only a particular subset of the data is considered. Here, we experimentally demonstrated an anomalous weak value can be obtained without discarding any data by performing a sequential weak measurement on a single-qubit system. By controlling the blazing density of the hologram on a spatial light modulator, the measurement strength can be conveniently controlled. Such an anomalous phenomenon disappears when the measurement strength becomes strong. Moreover, we find that the anomalous weak value can not be observed without post-selection when the sequential measurement is performed on each of the components of a two-qubit system, which confirms that the observed anomalous weak value is based on sequential weak measurement of two noncommutative operators.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا