Do you want to publish a course? Click here

A Multi-Channel Setup to Study Fractures in Scintillators

63   0   0.0 ( 0 )
 Added by Philippe Di Stefano
 Publication date 2016
  fields Physics
and research's language is English




Ask ChatGPT about the research

To investigate fractoluminescence in scintillating crystals used for particle detection, we have developed a multi-channel setup built around samples of double-cleavage drilled compression (DCDC) geometry in a controllable atmosphere. The setup allows the continuous digitization over hours of various parameters, including the applied load, and the compressive strain of the sample, as well as the acoustic emission. Emitted visible light is recorded with nanosecond resolution, and crack propagation is monitored using infrared lighting and camera. An example of application to Bi4Ge3O12 (BGO) is provided.



rate research

Read More

100 - A. Tantot , S. Santucci , O. Ramos 2013
Prompted by intriguing events observed in certain particle-physics searches for rare events, we study light and acoustic emission simultaneously in some inorganic scintillators subject to mechanical stress. We observe mechanoluminescence in ${Bi}_4{Ge}_{3}{O}_{12}$, ${CdWO}_{4}$ and ${ZnWO}_{4}$, in various mechanical configurations at room temperature and ambient pressure. We analyze how the light emission is correlated to acoustic emission during fracture. For ${Bi}_4{Ge}_{3}{O}_{12}$, we set a lower bound on the energy of the emitted light, and deduce that the fraction of elastic energy converted to light is at least $3 times 10^{-5}$.
102 - Jun Lu , De-An Pan , Lijie Qiao 2007
This letter presents principles and applications of a virtual multi-channel lock-in amplifier that is a simple but effective method to recover small ac signal from noise with high presison. The fundamentals of this method are based on calculation of cross-correlation function. Via this method, we successfully built up a magnetoelectric measurement system which can perform precise and versatile measurements without any analog lock-in amplifier. Using the virtual multi-channel lock-in amplifier, the output of the magnetoelectric measurement system is extensively rich in magnetoelectric coupling behaviors, including coupling strength and phase lag, under various dc bias magnetic field and ac magnetic field.
A simple method is presented for the simultaneous off-line synchronization of the digitally recorded data-streams from a multi-channel silicon telescope. The method is based both on the synchronization between the separate pairs of silicon strips and on the synchronization relative to an external timing device. Though only a reduced subset of these constraints is necessary in ideal circumstances, it is shown that this minimal set of conditions may not be sufficient for adequate synchronization in all cases. All available sources of information are therefore considered, in order to constrain the final synchronization as well as possible.
In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of the degree of similarity between the registered signals and the synchronized model signals stored in a library. The library was established for a set of well defined hit-positions along the length of the scintillator. The Mahalanobis distance was used as a measure of similarity between the two compared signals. The method was validated on the experimental data measured using two-strips J-PET prototype with dimensions of 5x9x300 mm$^3$. The obtained Time-of-Flight (TOF) and spatial resolutions amount to 325~ps (FWHM) and 25~mm (FWHM), respectively. The TOF resolution was also compared to the results of an analogous study done using Linear Fitting method. The best TOF resolution was obtained with this method at four pre-defined threshold levels which was comparable to the resolution achieved from the Mahalanobis distance at two pre-defined threshold levels. Although the algorithm of Linear Fitting method is much simpler to apply than the Mahalanobis method, the application of the Mahalanobis distance requires a lower number of applied threshold levels and, hence, decreases the costs of electronics used in PET scanner.
We propose and study a method of optical crosstalk suppression for silicon photomultipliers (SiPMs) using optical filters. We demonstrate that attaching absorptive visible bandpass filters to the SiPM can substantially reduce the optical crosstalk. Measurements suggest that the absorption of near infrared light is important to achieve this suppression. The proposed technique can be easily applied to suppress the optical crosstalk in SiPMs in cases where filtering near infrared light is compatible with the application.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا