Do you want to publish a course? Click here

Characterization of neutron transmutation doped (NTD) Ge for low temperature sensor development

107   0   0.0 ( 0 )
 Added by S Mathimalar
 Publication date 2014
  fields Physics
and research's language is English




Ask ChatGPT about the research

Development of NTD Ge sensors has been initiated for low temperature (mK) thermometry in The India-based Tin detector (TIN.TIN). NTD Ge sensors are prepared by thermal neutron irradiation of device grade Ge samples at Dhruva reactor, BARC, Mumbai. Detailed measurements have been carried out in irradiated samples for estimating the carrier concentration and fast neutron induced defects. The Positron Annihilation Lifetime Spectroscopy (PALS) measurements indicated monovacancy type defects for all irradiated samples, while Channeling studies employing RBS with 2 MeV alpha particles, revealed no significant defects in the samples exposed to fast neutron fluence of $sim 4times10^{16}/cm^2$. Both PALS and Channeling studies have shown that vacuum annealing at 600 $^circ$C for $sim2$ hours is sufficient to recover the damage in the irradiated samples, thereby making them suitable for the sensor development.

rate research

Read More

A new time projection chamber (TPC) was developed for neutron lifetime measurement using a pulsed cold neutron spallation source at the Japan Proton Accelerator Research Complex (J-PARC). Managing considerable background events from natural sources and the beam radioactivity is a challenging aspect of this measurement. To overcome this problem, the developed TPC has unprecedented features such as the use of polyether-ether-ketone plates in the support structure and internal surfaces covered with $^6$Li-enriched tiles to absorb outlier neutrons. In this paper, the design and performance of the new TPC are reported in detail.
Neutrinoless double-$beta$ decay of $^{76}$Ge is searched for with germanium detectors where source and detector of the decay are identical. For the success of future experiments it is important to increase the mass of the detectors. We report here on the characterization and testing of five prototype detectors manufactured in inverted coaxial (IC) geometry from material enriched to 88% in $^{76}$Ge. IC detectors combine the large mass of the traditional semi-coaxial Ge detectors with the superior resolution and pulse shape discrimination power of point contact detectors which exhibited so far much lower mass. Their performance has been found to be satisfactory both when operated in vacuum cryostat and bare in liquid argon within the GERDA setup. The measured resolutions at the Q-value for double-$beta$ decay of $^{76}$Ge (Q$_{betabeta}$ = 2039 keV) are about 2.1 keV full width at half maximum in vacuum cryostat. After 18 months of operation within the ultra-low background environment of the GERmanium Detector Array (GERDA) experiment and an accumulated exposure of 8.5 kg$cdot$yr, the background index after analysis cuts is measured to be $4.9^{+7.3}_{-3.4}times 10^{-4}$ counts /(keV$cdot$kg$cdot$yr) around Q$_{betabeta}$. This work confirms the feasibility of IC detectors for the next-generation experiment LEGEND.
We have experimentally characterized the light-output response of a deuterated trans-stilbene (stilbene-d12) crystal to quasi-monoenergetic neutrons in the 0.8 to 4.4 MeV energy range. These data allowed us to perform neutron spectroscopy measurements of a DT 14.1 MeV source and a PuBe-239 source by unfolding the impinging neutron spectrum from the measured light-output response. The stilbene-d12 outperforms a H1-stilbene of similar size when comparing the shape of the unfolded spectra and the reference ones. These results confirm the viability of non-hygroscopic stilbene-d12 crystal for direct neutron spectroscopy without need for time-of-flight measurements. This capability makes stilbene-d12 a well suited detector for fast-neutron spectroscopy in many applications including nuclear reaction studies, radiation protection, nuclear non-proliferation, and space travel.
Absolute measurements of neutron fluence are an essential prerequisite of neutron-induced cross section measurements, neutron beam lines characterization and dosimetric investigations. The H(n,p) elastic scattering cross section is a very well known standard used to perform precise neutron flux measurements in high precision measurements. The use of this technique, with proton recoil detectors, is not straightforward below incident neutron energy of 1 MeV, due to a high background in the detected proton spectrum. Experiments have been carried out at the AIFIRA facility to investigate such background and to determine its origin and components. Based on these investigations, a gaseous proton-recoil detector has been designed with a reduced low energy background. A first test of this detector has been carried out at the AIFIRA facility, and first results will be presented.
This paper presents the results of neutron flux measurements at two irradiation facilities of the TRIGA Mark II reactor at ENEA Casaccia Research Center, Italy. The goal of these measurements is to provide a complete characterization of neutron irradiation facilities for accurate and precise dose evaluation in radiation damage tests and, more generally, for all applications that need a good knowledge of neutron flux in terms of intensity, energy spectrum and spatial distribution. The neutron activation technique is used to measure the activation rates of several reactions, chosen so to cover the whole energy range of neutron flux spectrum. A multi-group neutron flux measurement is obtained through an unfolding algorithm based on a Bayesian statistical model. The obtained results prove that this experimental method allows to measure the total neutron flux within 2% statistical uncertainty, and to get at the same time a good description of its energy spectrum and spatial distribution.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا