Do you want to publish a course? Click here

Insensitivity of Ion Motional Heating Rate to Trap Material over a Large Temperature Range

128   0   0.0 ( 0 )
 Added by John Chiaverini
 Publication date 2013
  fields Physics
and research's language is English




Ask ChatGPT about the research

We present measurements of trapped-ion motional-state heating rates in niobium and gold surface-electrode ion traps over a range of trap-electrode temperatures from approximately 4 K to room temperature (295 K) in a single apparatus. Using the sideband-ratio technique after resolved-sideband cooling of single ions to the motional ground state, we find low-temperature heating rates more than two orders of magnitude below the room-temperature values and approximately equal to the lowest measured heating rates in similarly-sized cryogenic traps. We find similar behavior in the two very different electrode materials, suggesting that the anomalous heating process is dominated by non-material-specific surface contaminants. Through precise control of the temperature of cryopumping surfaces, we also identify conditions under which elastic collisions with the background gas can lead to an apparent steady heating rate, despite rare collisions.



rate research

Read More

391 - C.D. Bruzewicz , J.M. Sage , 2014
We present measurements of the motional heating rate of a trapped ion at different trap frequencies and temperatures between $sim$0.6 and 1.5 MHz and $sim$4 and 295 K. Additionally, we examine the possible effect of adsorbed surface contaminants with boiling points below $sim$105$^{circ}$C by measuring the ion heating rate before and after locally baking our ion trap chip under ultrahigh vacuum conditions. We compare the heating rates presented here to those calculated from available electric-field noise models. We can tightly constrain a subset of these models based on their expected frequency and temperature scaling interdependence. Discrepancies between the measured results and predicted values point to the need for refinement of theoretical noise models in order to more fully understand the mechanisms behind motional trapped-ion heating.
We have measured motional heating rates of trapped atomic ions, a factor that can influence multi-ion quantum logic gate fidelities. Two simplified techniques were developed for this purpose: one relies on Raman sideband detection implemented with a single laser source, while the second is even simpler and is based on time-resolved fluorescence detection during Doppler recooling. We applied these methods to determine heating rates in a microfrabricated surface-electrode trap made of gold on fused quartz, which traps ions 40 microns above its surface. Heating rates obtained from the two techniques were found to be in reasonable agreement. In addition, the trap gives rise to a heating rate of 300 plus or minus 30 per second for a motional frequency of 5.25 MHz, substantially below the trend observed in other traps.
We present a technique based on high resolution imaging to measure the absolute temperature and the heating rate of a single ion trapped at the focus of a deep parabolic mirror. We collect the fluorescence light scattered by the ion during laser cooling and image it onto a camera. Accounting for the size of the point-spread function and the magnification of the imaging system, we determine the spatial extent of the ion, from which we infer the mean phonon occupation number in the trap. Repeating such measurements and varying the power or the detuning of the cooling laser, we determine the anomalous heating rate. In contrast to other established schemes for measuring the heating rate, one does not have to switch off the cooling but the ion is always maintained in a state of thermal equilibrium at temperatures close to the Doppler limit.
We employ spin-dependent optical dipole forces to characterize the transverse center-of-mass (COM) motional mode of a two-dimensional Wigner crystal of hundreds of $^9$Be$^+$. By comparing the measured spin dephasing produced by the spin-dependent force with the predictions of a semiclassical dephasing model, we obtain absolute mode temperatures in excellent agreement with both the Doppler laser cooling limit and measurements obtained from a previously published technique (B. C. Sawyer et al. Phys. Rev. Lett. textbf{108}, 213003 (2012)). Furthermore, the structure of the dephasing histograms allows for discrimination between initial thermal and coherent states of motion. We also apply the techniques discussed here to measure, for the first time, the ambient heating rate of the COM mode of a 2D Coulomb crystal in a Penning trap. This measurement places an upper limit on the anomalous single-ion heating rate due to electric field noise from the trap electrode surfaces of $frac{dbar{n}}{dt}sim 5$ s$^{-1}$ for our trap at a frequency of 795 kHz, where $bar{n}$ is the mean occupation of quantized COM motion in the axial harmonic well.
134 - G. Shu , G. Vittorini , C. Volin 2014
We measure ion heating following transport throughout a Y-junction surface-electrode ion trap. By carefully selecting the trap voltage update rate during adiabatic transport along a trap arm, we observe minimal heating relative to the anomalous heating background. Transport through the junction results in an induced heating between 37 and 150 quanta in the axial direction per traverse. To reliably measure heating in this range, we compare the experimental sideband envelope, including up to fourth-order sidebands, to a theoretical model. The sideband envelope method allows us to cover the intermediate heating range inaccessible to the first-order sideband and Doppler recooling methods. We conclude that quantum information processing in this ion trap will likely require sympathetic cooling in order to support high fidelity gates after junction transport.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا