INTEGRAL IBIS/ISGRI energy calibration in OSA 10


Abstract in English

We present the new energy calibration of the ISGRI detector onboard INTEGRAL, that has been implemented in the Offline Scientific Analysis (OSA) version 10. With the previous OSA 9 version, a clear departure from stability of both W and 22Na background lines was observed after MJD 54307 (revolution ~583). To solve this problem, the energy correction in OSA 10 uses: 1) a new description for the gain depending on the time and the pulse rise time, 2) an improved temperature correction per module, and 3) a varying shape of the low threshold, corrected for the change in energy resolution. With OSA 10, both background lines show a remarkably stable behavior with a relative energy variation below 1% around the nominal position (>6% in OSA 9), and the energy reconstruction at low energies is more stable compared to previous O

Download