Do you want to publish a course? Click here

Super-resolution ghost imaging via compressive sampling reconstruction

123   0   0.0 ( 0 )
 Added by Gong Wenlin
 Publication date 2009
  fields Physics
and research's language is English




Ask ChatGPT about the research

For ghost imaging, pursuing high resolution images and short acquisition times required for reconstructing images are always two main goals. We report an image reconstruction algorithm called compressive sampling (CS) reconstruction to recover ghost images. By CS reconstruction, ghost imaging with both super-resolution and a good signal-to-noise ratio can be obtained via short acquisition times. Both effect influencing and approaches further improving the resolution of ghost images via CS reconstruction, relationship between ghost imaging and CS theory are also discussed.



rate research

Read More

188 - Wenlin Gong , , Shensheng Han 2009
Much more image details can be resolved by improving the systems imaging resolution and enhancing the resolution beyond the systems Rayleigh diffraction limit is generally called super-resolution. By combining the sparse prior property of images with the ghost imaging method, we demonstrated experimentally that super-resolution imaging can be nonlocally achieved in the far field even without looking at the object. Physical explanation of super-resolution ghost imaging via compressive sampling and its potential applications are also discussed.
209 - Wenlin Gong , , Shensheng Han 2010
Based on compressive sampling techniques and short exposure imaging, super-resolution imaging with thermal light is experimentally demonstrated exploiting the sparse prior property of images for standard conventional imaging system. Differences between super-resolution imaging demonstrated in this letter and super-resolution ghost imaging via compressive sampling (arXiv. Quant-ph/0911.4750v1 (2009)), and methods to further improve the imaging quality are also discussed.
118 - Wenlin Gong , , Shensheng Han 2009
Both ghost imaging (GI) and ghost imaging via compressive sampling (GICS) can nonlocally image an object. We report the influence of spatial transverse coherence property of a thermal source on GI and GICS and show that, using the same acquisition numbers, the signal-to-noise ratio (SNR) of images recovered by GI will be reduced while the quality of reconstructed images will be enhanced for GICS as the spatial transverse coherence lengths located on the object plane are decreased. Differences between GI and GICS, methods to further improve the quality and image extraction efficiency of GICS, and its potential applications are also discussed.
109 - Xiao-Peng Jin 2021
Mid-wave infrared (MWIR) cameras for large number pixels are extremely expensive compared with their counterparts in visible light, thus, super-resolution imaging (SRI) for MWIR by increasing imaging pixels has always been a research hotspot in recent years. Over the last decade, with the extensively investigation of the compressed sensing (CS) method, focal plane array (FPA) based compressive imaging in MWIR developed rapidly for SRI. This paper presents a long-distance super-resolution FPA compressive imaging in MWIR with improved calibration method and imaging effect. By the use of CS, we measure and calculate the calibration matrix of optical system efficiently and precisely, which improves the imaging contrast and signal-to-noise ratio(SNR) compared with previous work. We also achieved the 4x4 times super-resolution reconstruction of the long-distance objects which reaches the limit of the system design in our experiment.
As one of important analysis tools, microscopes with high spatial resolution are indispensable for scientific research and medical diagnosis, and much attention is always focused on the improvement of resolution. Over the past decade, a novel technique called ghost imaging has been developed that may provide a new approach toward increasing the resolution of an imaging system. In this paper, we introduce this technique into microscopes for the first time and report a proof-of-principle experimental demonstration of a microscope scheme based on ghost imaging.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا