Chemical Inhibition for Steel Corrosion In Acidic Media, Using Vanillin


Abstract in English

The corrosion inhibition of transmision steel in 1M HCl solution in the presence of Vanillin at temperature (20,30,40,50,60)°C at concentration between (100-500) ppm for two hours were studied using weight loss method.

References used

POPOV B, 2015 Evaluation of corrosion Corrosion Engineering ,Elsevier B.V. , Columbia , 1-28
POPOV B, 2015. Thermodynamics in the Electrochemical Reactions of Corrosion, Corrosion Engineering ,Elsevier B.V. , Columbia , 29
FARHAN A , et al. , 2014 A Study Of Corrosion Behavior Of Low Carbon Steel In Acidic And Basic Washing Water Of Crude Oil Solution At Different Temperatures J. Baghdad for Sci,Vol.11(4) , 1510-1518