Because of the importance of water hummer and it’s big impact in pumping pipes, an analytical study of water hummer resulting from the pumping station abruptly stopped working (due to a power outage on water pipe line that conveys water from ground open tank to three overhead open tanks was conducted, and without means of protection from water hummer . maximum and minimum pressure values and the location of each of them in the network have been identified. It was found that the pump trip caused a transient state with negative pressure along the pipe system. The values of maximum pressure were less than the pressure tube run.