Cracks are considered important defects in concrete elements, it was noticed after constructing the reinforced concrete walls related to the Foundation, that after a short time after the hardening of concrete and without any overloading on the wall, there have been vertical cracks of regular distances along each wall we noticed this phenomenon it had happened in many construction projects. We have described the situation, we have also explained, analyzed it by examining its reasons. By a thorough study of three projects carried out in lattakia including scale decanter, building of a tourist hotel and a trade centre, which crack width ranging from 1.25 mm to 3 mm, the height differed in each case studied. Ultimately we have found the practical solutions to avoid this phenomenon including adoption of longitudinal joints for reinforced concrete walls, spacing is about thirty times the wall thickness in order to avoid cracks caused by shrinkage and thermal stress where the depth of joint about 20 mm and the width ranging between 15 mm to 20 mm implemented on both sides of the wall internal and external. After hardening of concrete and lifting the wooden template fill the joints with filler flexible materials.