Do you want to publish a course? Click here

Study of Beam Energy Spectrum Measurement in the NLC Extraction Line

92   0   0.0 ( 0 )
 Added by Yuri Nosochkov
 Publication date 2001
  fields Physics
and research's language is English




Ask ChatGPT about the research

The NLC extraction line provides a secondary focal point with a low beta function and 2 cm dispersion which can be used for measurement of the beam energy spectrum. In this study, tracking simulations were performed to transport the 0.5 TeV electron beam from the Interaction Point (IP) to the secondary focus (SF), ``measure the resultant transverse beam profile and reconstruct the disrupted IP energy spread. In the simulation, the obtained energy spectrum reproduced the initial IP spread reasonably well, especially with the vertical dispersion at SF which provides larger ratio of dispersion to the betatron beam size.



rate research

Read More

In this note, we briefly review the current lattice of the NLC extraction line which was designed for the nominal NLC beam parameters. Then we describe the beam parameters for the high luminosity option with larger beam disruption parameter and discuss its effect on beam loss in the extraction line. Finally, we present a summary of the optics study aimed at minimizing the beam loss with high disruption beams.
Properties of the disrupted NLC beam at the Interaction Point (IP) and particle loss in the extraction line are analyzed as a function of beam-to-beam position and angular offset at IP. The simulations show that disruption and beam loss maximize when the vertical beam separation at IP is about 20 times the rms vertical beam size. The horizontal offset does not increase the disruption and the beam loss. The angular offsets cause particle loss in the extraction line mainly because of the beam orbit oscillations.
We explore the NLC linac optics compatible with a low energy scenario where initially only part of the full linac is installed. Optics modification suitable for a low energy beam running and upgrade to the nominal energy is discussed. Linac parameters and beam tolerances in the modified lattice are compared to the nominal design.
Extensive beam-based feedback systems are planned as an integral part of the Next Linear Collider (NLC) control system. Wakefield effects are a significant influence on the feedback design, imposing both architectural and algorithmic constraints. Studies are in progress to assure the optimal selection of devices and to refine and confirm the algorithms for the system design. We show the results of initial simulations, along with evaluations of system response for various conditions of ground motion and other operational disturbances.
Realistic calculation of NLC luminosity has been performed using particle tracking in DIMAD and beam-beam simulations in GUINEA-PIG code for various values of beam emittance, energy and beta functions at the Interaction Point (IP). Results of the simulations are compared with analytic luminosity calculations. The optimum range of IP beta functions for high luminosity was identified.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا