Do you want to publish a course? Click here

A Novel Manufacturing Process for Glass THGEMs and First Characterisation in an Optical Gaseous Argon TPC

238   0   0.0 ( 0 )
 Added by Barney Philippou
 Publication date 2021
  fields Physics
and research's language is English




Ask ChatGPT about the research

This paper details a novel, patent pending, abrasive machining manufacturing process for the formation of sub-millimetre holes in THGEMs, with the intended application in gaseous and dual-phase TPCs. Abrasive machining favours a non-ductile substrate such as glasses or ceramics. This innovative manufacturing process allows for unprecedented versatility in THGEM substrates, electrodes, and hole geometry and pattern. Consequently, THGEMs produced via abrasive machining can be tailored for specific properties, for example: high stiffness, low total thickness variation, radiopurity, moisture absorption/outgassing and/or carbonisation resistance. This paper specifically focuses on three glass substrate THGEMs (G-THGEMs) made from Schott Borofloat 33 and Fused Silica. Circular and hexagonal hole shapes are also investigated. The G-THGEM electrodes are made from Indium Tin Oxide (ITO), with a resistivity of 150 $Omega$/Sq. All G-THGEMs were characterised in an optical (EMCCD) readout GArTPC, and compared to a traditionally manufactured FR4 THGEM, with their charging and secondary scintillation (S2) light production behaviour analysed.



rate research

Read More

Plastic scintillator detectors are widely used in particle physics thanks to the very good particle identification, tracking capabilities and time resolution. However, new experimental challenges and the need for enhanced performance require the construction of detector geometries that are complicated using the current production techniques. In this article we propose a new production technique based on additive manufacturing that aims to 3D print polystyrene-based scintillator. The production process and the results of the scintillation light output measurement of the 3D-printed scintillator are reported.
Recently a large interest has been shown for multi-ton Liquid Argon Time-Projection-Chambers (LAr-TPC). The physics issues are very challenging, but the technical problem of long drifts and adequately long life-time of free electrons are not solved at all so far. Also one should take into account the extremely large number of channels required for such large volumes. In this paper we propose an architecture for DAQ that is based on recent developments in consumer electronics that made available, at a quite interesting price, components aimed to high-resolution delta-sigma conversion. This type of ADC is not at all popular in HEP experiments where normally signals related to events, well defined in time (triggered), should be converted and recorded. In the LAr-TPC however we have to deal rather with waveforms that should be converted and recorded continuously, that is the paramount case of delta-sigma ADC application.
The CYGNO project has the goal to use a gaseous TPC with optical readout to detect dark matter and solar neutrinos with low energy threshold and directionality. The CYGNO demonstrator will consist of 1 m 3 volume filled with He:CF 4 gas mixture at atmospheric pressure. Optical readout with high granularity CMOS sensors, combined with fast light detectors, will provide a detailed reconstruction of the event topology. This will allow to discriminate the nuclear recoil signal from the background, mainly represented by low energy electron recoils induced by radioactivity. Thanks to the high reconstruction efficiency, CYGNO will be sensitive to low mass dark matter, and will have the potential to overcome the neutrino floor, that ultimately limits non-directional dark matter searches.
We have demonstrated experimentally that recently developed gaseous detectors combined with solid or gaseous photo-cathodes have exceptionally low noise and high quantum efficiency for UV photons while being solar blind. For this reason they can be used for the detection of weak UV sources in daylight conditions. These detectors are extremely robust, can operate in poor gas conditions and are cheap. We present the first results of their applications to hyper-spectroscopy and flame detection in daylight conditions.
220 - K. Mavrokoridis 2011
Future giant liquid argon (LAr) time projection chambers (TPCs) require a purity of better than 0.1 parts per billion (ppb) to allow the ionised electrons to drift without significant capture by any electronegative impurities. We present a comprehensive study of the effects of electronegative impurity on gaseous and liquid argon scintillation light, an analysis of the efficacy of various purification chemicals, as well as the Liverpool LAr setup, which utilises a novel re-circulation purification system. Of the impurities tested - Air, O_2, H_2O, N_2 and CO_2 in the range of between 0.01 ppm to 1000 ppm - H_2O was found to have the most profound effect on gaseous argon scintillation light, and N_2 was found to have the least. Additionally, a correlation between the slow component decay time and the total energy deposited with 0.01 ppm - 100 ppm O_2 contamination levels in liquid argon has been established. The superiority of molecular sieves over anhydrous complexes at absorbing Ar gas, N_2 gas and H_2O vapour has been quantified using BET isotherm analysis. The efficiency of Cu and P_2O5 at removing O_2 and H_2O impurities from 1 bar N6 argon gas at both room temperature and -130 ^oC was investigated and found to be high. A novel, highly scalable LAr re-circulation system has been developed. The complete system, consisting of a motorised bellows pump operating in liquid and a purification cartridge, were designed and built in-house. The system was operated successfully over many days and achieved a re-circulation rate of 27 litres/hour and high purity.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا