Thoracic endovascular aortic repair (TEVAR) has become the standard treatment of a variety of aortic pathologies. The objective of this study is to evaluate the hemodynamic effects of stent-graft introducer sheath during TEVAR. Three idealized representative diseased aortas of aortic aneurysm, coarctation of the aorta, and aortic dissection were designed. Computational fluid dynamics studies were performed in the above idealized aortic geometries. An introducer sheath routinely used in the clinic was virtually-delivered into diseased aortas. Comparative analysis was carried out to evaluate the hemodynamic effects of the introducer sheath. Results show that the blood flow to the supra-aortic branches would increase above 9% due to the obstruction of the introducer sheath. The region exposed to high endothelial cell activation potential (ECAP) expands in the scenarios of coarctation of the aorta and aortic dissection, which indicates that the probability of thrombus formation may increase during TEVAR. The pressure magnitude in peak systole shows an obvious rise and a similar phenomenon is not observed in early diastole. The blood viscosity in the aortic arch and descending aorta is remarkably altered by the introducer sheath. The uneven viscosity distribution confirms the necessity of using non-Newtonian models and high viscosity region with high ECAP further promotes thrombosis. Our results highlight the hemodynamic effects of stent-graft introducer sheath during TEVAR, which may associate with perioperative complications.
Thoracic endovascular aortic repair (TEVAR) has developed to be the most effective treatment for aortic diseases. The objective of this study is to evaluate the biomechanical implications of the implanted endograft after TEVAR. We present a novel image-based, patient-specific, fluid-structure computational framework. The geometries of blood, endograft, and aortic wall were reconstructed based on clinical images. Patient-specific measurement data was collected to determine the parameters of the three-element Windkessel. We designed three postoperative scenarios with rigid wall assumption, blood-wall interaction, blood-endograft-wall interplay, respectively, where a two-way fluid-structure interaction (FSI) method was applied to predict the deformation of the composite stent-wall. Results show that flow energy loss (EL) during a cardiac cycle is underestimated by the rigid wall assumption. The complete storage and release process of blood flow energy, which consists of four phases is firstly captured. The implantation of the endograft would weaken the buffer function of the aorta and reduce mean EL by 19.1%. The closed curve area of wall pressure and aortic volume could indicate the EL caused by the interaction between blood flow and wall deformation. Both the FSI and endograft have a slight effect on wall shear stress-related-indices. The deformability of the composite stent-wall region is remarkably limited by the endograft. Our results highlight the importance of considering both the FSI method and the biomechanical implications of endograft to acquire physiologically-accurate hemodynamics in post-TEVAR computational studies and that neglecting the effect of the endograft would overestimate the blood flow EL and aortic deformability.
Endovascular sealing is a new technique for the repair of abdominal aortic aneurysms. Commercially available in Europe since~2013, it takes a revolutionary approach to aneurysm repair through minimally invasive techniques. Although aneurysm sealing may be thought as more stable than conventional endovascular stent graft repairs, post-implantation movement of the endoprosthesis has been described, potentially leading to late complications. The paper presents for the first time a model, which explains the nature of forces, in static and dynamic regimes, acting on sealed abdominal aortic aneurysms, with references to real case studies. It is shown that elastic deformation of the aorta and of the endoprosthesis induced by static forces and vibrations during daily activities can potentially promote undesired movements of the endovascular sealing structure.
Peripheral nerve injuries are difficult to treat due to limited axon regeneration; brief electrical stimulation of injured nerves is an emerging therapy that can relieve pain and enhance regeneration. We report an original wireless stimulator based on a metal loop (diameter ~1 mm) that is powered by a transcranial magnetic stimulator (TMS). The loop can be integrated in a chitosan scaffold that functions as a graft when applied onto transected nerves (graft-antenna). The graft-antenna was bonded to rat sciatic nerves by a laser without sutures; it did not migrate after implantation and was able to trigger steady compound muscle action potentials for 12 weeks (CMAP ~1.3 mV). Eight weeks post-operatively, axon regeneration was facilitated in transected nerves that were repaired with the graft-antenna and stimulated by the TMS for 1 hour/week. The graft-antenna is an innovative and minimally-invasive device that functions concurrently as a wireless stimulator and adhesive scaffold for nerve repair.
Tracking and characterizing the blood uptake process within solid pancreatic tumors and the subsequent spatio-temporal distribution of red blood cells are critical to the clinical diagnosis of the cancer. This systematic computational study of physical factors, affecting the percolation and penetration of blood into a solid tumor, can assist in the development of a new objective clinical diagnosis approach and a framework for personalized targeted drugs.
The SARS-CoV-2 virus is primarily transmitted through virus-laden fluid particles ejected from the mouth of infected people. Face covers can mitigate the risk of virus transmission but their outward effectiveness is not fully ascertained. Objective: by using a background oriented schlieren technique, we aim to investigate the air flow ejected by a person while quietly and heavily breathing, while coughing, and with different face covers. Results: we found that all face covers without an outlet valve reduce the front flow through by at least 63% and perhaps as high as 86% if the unfiltered cough jet distance was resolved to the anticipated maximum distance of 2-3 m. However, surgical and handmade masks, and face shields, generate significant leakage jets that may present major hazards. Conclusions: the effectiveness of the masks should mostly be considered based on the generation of secondary jets rather than on the ability to mitigate the front throughflow.