Do you want to publish a course? Click here

The Mu3e experiment: Toward the construction of an HV-MAPS vertex detector

76   0   0.0 ( 0 )
 Added by Thomas Rudzki
 Publication date 2021
  fields Physics
and research's language is English




Ask ChatGPT about the research

The Mu3e experiment searches for the lepton flavor violating decay $mu^+~rightarrow~e^+~e^+~e^-$ with an ultimate aimed sensitivity of 1 event in $10^{16}$ decays. This goal can only be achieved by reducing the material budget per tracking layer to $X/X_0 approx 0.1 %$. High-Voltage Monolithic Active Pixel Sensors (HV-MAPS) which are thinned to $50 mu m$ serve as sensors. Gaseous helium is chosen as coolant. Results of recent studies related to the sensor prototypes, the helium cooling, and module prototyping are presented. The recent chip submission MuPix10 has proven its functionality regarding efficiency and time resolution. The helium cooling system for the inner tracker could be verified using a full-scale prototype. A complete prototype equipped with MuPix10 chips will be tested inside the Mu3e magnet in summer 2021.



rate research

Read More

111 - K. Arndt , H. Augustin , P. Baesso 2020
The Mu3e experiment aims to find or exclude the lepton flavour violating decay $mu rightarrow eee$ at branching fractions above $10^{-16}$. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of $2cdot 10^{-15}$. We present an overview of all aspects of the technical design and expected performance of the phase~I Mu3e detector. The high rate of up to $10^{8}$ muon decays per second and the low momenta of the decay electrons and positrons pose a unique set of challenges, which we tackle using an ultra thin tracking detector based on high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements.
Mu3e is a novel experiment searching for charged lepton flavor violation in the rare decay $mu^+ rightarrow e^+e^-e^+$. Decay vertex position, decay time and particle momenta have to be precisely measured in order to reject both accidental and physics background. A silicon pixel tracker based on $50,mu$m thin high voltage monolithic active pixel sensors (HV-MAPS) in a 1 T solenoidal magnetic field provides precise vertex and momentum information. The MuPix chip combines pixel sensor cells with integrated analog electronics and a periphery with a complete digital readout. The MuPix7 is the first HV-MAPS prototype implementing all functionalities of the final sensor including a readout state machine and high speed serialization with 1.25 Gbit/s data output, allowing for a streaming readout in parallel to the data taking. The observed efficiency of the MuPix7 chip including the full readout system is $geq99%$ in a high rate test beam.
A Hadron Blind Detector (HBD) has been developed, constructed and successfully operated within the PHENIX detector at RHIC. The HBD is a Cherenkov detector operated with pure CF4. It has a 50 cm long radiator directly coupled in a window- less configuration to a readout element consisting of a triple GEM stack, with a CsI photocathode evaporated on the top surface of the top GEM and pad readout at the bottom of the stack. This paper gives a comprehensive account of the construction, operation and in-beam performance of the detector.
LHCb is one of the four main experiments of the Large Hadron Collider (LHC) project, which will start at CERN in 2008. The experiment is primarily dedicated to B-Physics and hence requires precise vertex reconstruction. The silicon vertex locator (VELO) has a single hit precision of better than 10 micron and is used both off-line and in the trigger. These requirements place strict constraints on its alignment. Additional challenges for the alignment arise from the detector being retracted between each fill of the LHC and from its unique circular disc r/phi strip geometry. This paper describes the track based software alignment procedure developed for the VELO. The procedure is primarily based on a non-iterative method using a matrix inversion technique. The procedure is demonstrated with simulated events to be fast, robust and to achieve a suitable alignment precision.
A new silicon detector has been developed to provide the PHENIX experiment with precise charged particle tracking at forward and backward rapidity. The Forward Silicon Vertex Tracker (FVTX) was installed in PHENIX prior to the 2012 run period of the Relativistic Heavy Ion Collider (RHIC). The FVTX is composed of two annular endcaps, each with four stations of silicon mini-strip sensors, covering a rapidity range of $1.2<|eta|<2.2$ that closely matches the two existing PHENIX muon arms. Each station consists of 48 individual silicon sensors, each of which contains two columns of mini-strips with 75 $mu$m pitch in the radial direction and lengths in the $phi$ direction varying from 3.4 mm at the inner radius to 11.5 mm at the outer radius. The FVTX has approximately 0.54 million strips in each endcap. These are read out with FPHX chips, developed in collaboration with Fermilab, which are wire bonded directly to the mini-strips. The maximum strip occupancy reached in central Au-Au collisions is approximately 2.8%. The precision tracking provided by this device makes the identification of muons from secondary vertices away from the primary event vertex possible. The expected distance of closest approach (DCA) resolution of 200 $mu$m or better for particles with a transverse momentum of 5 GeV/$c$ will allow identification of muons from relatively long-lived particles, such as $D$ and $B$ mesons, through their broader DCA distributions.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا