Do you want to publish a course? Click here

Magnetic Particle Spectroscopy (MPS) with One-stage Lock-in Implementation for Magnetic Bioassays with Improved Sensitivities

163   0   0.0 ( 0 )
 Added by Vinit Chugh
 Publication date 2021
and research's language is English




Ask ChatGPT about the research

In recent years, magnetic particle spectroscopy (MPS) has become a highly sensitive and versatile sensing technique for quantitative bioassays. It relies on the dynamic magnetic responses of magnetic nanoparticles (MNPs) for the detection of target analytes in liquid phase. There are many research studies reporting the application of MPS for detecting a variety of analytes including viruses, toxins, and nucleic acids, etc. Herein, we report a modified version of MPS platform with the addition of a one-stage lock-in design to remove the feedthrough signals induced by external driving magnetic fields, thus capturing only MNP responses for improved system sensitivity. This one-stage lock-in MPS system is able to detect as low as 781 ng multi-core Nanomag50 iron oxide MNPs (micromod Partikeltechnologie GmbH) and 78 ng single-core SHB30 iron oxide MNPs (Ocean NanoTech). In addition, using a streptavidin-biotin binding system as a proof-of-concept, we show that these single-core SHB30 MNPs can be used for Brownian relaxation-based bioassays while the multi-core Nanomag50 cannot be used. The effects of MNP amount on the concentration dependent response profiles for detecting streptavidin was also investigated. Results show that by using lower concentration/amount of MNPs, concentration-response curves shift to lower concentration/amount of target analytes. This lower concentrationresponse indicates the possibility of improved bioassay sensitivities by using lower amounts of MNPs.



rate research

Read More

Nowadays, there is an increasing demand for more accessible routine diagnostics for patients with respect to high accuracy, ease of use, and low cost. However, the quantitative and high accuracy bioassays in large hospitals and laboratories usually require trained technicians and equipment that is both bulky and expensive. In addition, the multi-step bioassays and long turnaround time could severely affect the disease surveillance and control especially in pandemics such as influenza and COVID-19. In view of this, a portable, quantitative bioassay device will be valuable in regions with scarce medical resources and help relieve burden on local healthcare systems. Herein, we introduce the MagiCoil diagnostic device, an inexpensive, portable, quantitative and rapid bioassay platform based on magnetic particle spectrometer (MPS) technique. MPS detects the dynamic magnetic responses of magnetic nanoparticles (MNPs) and uses the harmonics from oscillating MNPs as metrics for sensitive and quantitative bioassays. This device does not require trained technicians to operate and employs a fully automatic, one-step, wash-free assay with user friendly smartphone interface. Using a streptavidin-biotin binding system as a model, we show that the detection limit of the current portable device for streptavidin is 64 nM (equal to 5.12 pmole). In addition, this MPS technique is very versatile and allows for the detection of different diseases just by changing the surface modifications on MNPs.
303 - Kai Wu , Jinming Liu , Renata Saha 2019
Magnetic nanoparticles (MNPs) with proper surface functionalization have been extensively applied as labels for magnetic immunoassays, carriers for controlled drug/gene delivery, tracers and contrasts for magnetic imaging, etc. Here, we introduce a new biosensing scheme based on magnetic particle spectroscopy (MPS) and the self-assembly of MNPs to quantitatively detect H1N1 nucleoprotein molecules. MPS monitors the harmonics of oscillating MNPs as a metric for the freedom of rotational motion, thus indicating the bound states of MNPs. These harmonics can be readily collected from nanogram quantities of iron oxide nanoparticles within 10 s. H1N1 nucleoprotein molecule hosts multiple different epitopes that forms binding sites for many IgG polyclonal antibodies. Anchoring IgG polyclonal antibodies onto MNPs triggers the cross-linking between MNPs and H1N1 nucleoprotein molecules, thereby forming MNP self-assemblies. Using MPS and the self-assembly of MNPs, we achieved the sensitivity of 44 nM (442 pmole) for detecting H1N1 nucleoprotein. In addition, the morphologies and the hydrodynamic sizes of the MNP self-assemblies are characterized to verify the MPS results. Different MNP self-assembly models such as classical cluster, open ring tetramer, chain model as well as multimers (from dimer to pentamer) are proposed in this paper. Herein, we claim the feasibility of using MPS and the self-assembly of MNPs as a new biosensing scheme for detecting ultralow concentrations of target biomolecules, which can be employed as rapid, sensitive, and wash-free magnetic immunoassays.
134 - Kai Wu , Diqing Su , Renata Saha 2020
Magnetic particle spectroscopy (MPS), also called magnetization response spectroscopy, is a novel measurement tool derived from magnetic particle imaging (MPI). It can be interpreted as a zero-dimensional version of MPI scanner. MPS was primarily designed for characterizing superparamagnetic iron oxide nanoparticles (SPIONs) regarding their applicability for MPI. In recent years, it has evolved into an independent, versatile, highly sensitive, inexpensive platform for biological and biomedical assays, cell labeling and tracking, and blood analysis. MPS has also developed into an auxiliary tool for magnetic imaging and hyperthermia by providing high spatial and temporal mappings of temperature and viscosity. Furthermore, other MPS-based applications are being explored such as magnetic fingerprints for product tracking and identification in supply chains. There are a variety of novel MPS-based applications being reported and demonstrated by many groups. In this short review, we highlighted some of the representative applications based on MPS platform, thereby providing a roadmap of this technology and our insights for researchers in this area.
With the ongoing global pandemic of coronavirus disease 2019 (COVID-19), there is an increasing quest for more accessible, easy-to-use, rapid, inexpensive, and high accuracy diagnostic tools. Traditional disease diagnostic methods such as qRT-PCR (quantitative reverse transcription-PCR) and ELISA (enzyme-linked immunosorbent assay) require multiple steps, trained technicians, and long turnaround time that may worsen the disease surveillance and pandemic control. In sight of this situation, a rapid, one-step, easy-to-use, and high accuracy diagnostic platform will be valuable for future epidemic control especially for regions with scarce medical resources. Herein, we report a magnetic particle spectroscopy (MPS) platform for detection of SARS-CoV-2 biomarkers: spike and nucleocapsid proteins.
Magnetic resonance force microscopy (MRFM) is a scanning probe technique capable of detecting MRI signals from nanoscale sample volumes, providing a paradigm-changing potential for structural biology and medical research. Thus far, however, experiments have not reached suffcient spatial resolution for retrieving meaningful structural information from samples. In this work, we report MRFM imaging scans demonstrating a resolution of 0.9 nm and a localization precision of 0.6 nm in one dimension. Our progress is enabled by an improved spin excitation protocol furnishing us with sharp spatial control on the MRFM imaging slice, combined with overall advances in instrument stability. From a modeling of the slice function, we expect that our arrangement supports spatial resolutions down to 0.3 nm given suffcient signal-to-noise ratio. Our experiment demonstrates the feasibility of sub-nanometer MRI and realizes an important milestone towards the three-dimensional imaging of macromolecular structures.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا