No Arabic abstract
Six-axes force/torque sensors are increasingly needed in mechanical engineering. Here, we introduce a flexure-based design for such sensors, which solves some of the drawbacks of the existing designs. In particular, it is backlash-free, it can be wirelessly monitored, it exactly enforces 90 degrees angles between axes, and it enables visual inspection of the monitored system thanks to its hollow structure. We first describe the generic design, implementation and calibration procedure. We then demonstrate its capabilities through three illustration examples relevant to the field of tribology: low friction measurements under ultra-high vacuum, multi-directional friction measurements of elastomer contacts, and force/torque-based contact position monitoring.
The knowledge of transitions between regular, laminar or chaotic behavior is essential to understand the underlying mechanisms behind complex systems. While several linear approaches are often insufficient to describe such processes, there are several nonlinear methods which however require rather long time observations. To overcome these difficulties, we propose measures of complexity based on vertical structures in recurrence plots and apply them to the logistic map as well as to heart rate variability data. For the logistic map these measures enable us not only to detect transitions between chaotic and periodic states, but also to identify laminar states, i.e. chaos-chaos transitions. The traditional recurrence quantification analysis fails to detect the latter transitions. Applying our new measures to the heart rate variability data, we are able to detect and quantify the laminar phases before a life-threatening cardiac arrhythmia occurs thereby facilitating a prediction of such an event. Our findings could be of importance for the therapy of malignant cardiac arrhythmias.
Photoplethysmography (PPG) is a method of detecting variation in blood volume commonly through contact with the skin and involving the usage of one or multiple sensors. PPG is typically used in health-related fields and one of its most popular uses is heart rate monitoring. Recent developments in technology have introduced wearable smart devices that can detect PPG signals. These devices mostly rely on signals that are detected at a single location, indicating that such devices require the signal waveform to be immensely reliable. In further detail, the properties of the blood circulation system are being deducted from the heartbeat signal profile. One disadvantage is that the waveform can be affected by tissues that surround the blood vessels. This may result in the unreliability of the methods utilized by many wearable smart devices. This paper introduces an experimental study on the deformation of waveform change caused by sensor binding force. The results of the study are that an increase in sensor binding force decreases the width of the pump strength-related pulse.
Retrieving rich contact information from robotic tactile sensing has been a challenging, yet significant task for the effective perception of object properties that the robot interacts with. This work is dedicated to developing an algorithm to estimate contact force and torque for vision-based tactile sensors. We first introduce the observation of the contact deformation patterns of hyperelastic materials under ideal single-axial loads in simulation. Then based on the observation, we propose a method of estimating surface forces and torque from the contact deformation vector field with the Helmholtz-Hodge Decomposition (HHD) algorithm. Extensive experiments of calibration and baseline comparison are followed to verify the effectiveness of the proposed method in terms of prediction error and variance. The proposed algorithm is further integrated into a contact force visualization module as well as a closed-loop adaptive grasp force control framework and is shown to be useful in both visualization of contact stability and minimum force grasping task.
In this paper we have used one 2 variable Boolean function called Rule 6 to define another beautiful transformation named as Extended Rule-6. Using this function we have explored the algebraic beauties and its application to an efficient Round Robin Tournament (RRT) routine for 2k (k is any natural number) number of teams. At the end, we have thrown some light towards any number of teams of the form nk where n, k are natural numbers.
Every university introductory physics course considers the problem of Atwoods machine taking into account the mass of the pulley. In the usual treatment the tensions at the two ends of the string are offhandedly taken to act on the pulley and be responsible for its rotation. However such a free-body diagram of the forces on the pulley is not {it a priori} justified, inducing students to construct wrong hypotheses such as that the string transfers its tension to the pulley or that some symmetry is in operation. We reexamine this problem by integrating the contact forces between each element of the string and the pulley and show that although the pulley does behave as if the tensions were acting on it, this comes only as the end result of a detailed analysis. We also address the question of how much friction is needed to prevent the string from slipping over the pulley. Finally, we deal with the case in which the string is on the verge of sliding and show that this will never happen unless certain conditions are met by the coefficient of friction and the masses involved.